MPManuel Post

Manuel Post

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Manuel Post has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Two for One—Combined Morphologic and Quantitative Knee Joint MRI Using a Versatile Turbo Spin-Echo Platform

    by Teresa Lemainque, Nicola Pridöhl, Marc Huppertz, Manuel Post, Can Yüksel, Robert Siepmann, Karl Ludger Radke, Shuo Zhang, Masami Yoneyama, Andreas Prescher, et al.

    Quantitative MRI techniques such as T2 and T1ρ mapping are beneficial in evaluating knee joint pathologies; however, long acquisition times limit their clinical adoption. MIXTURE (Multi-Interleaved X-prepared Turbo Spin-Echo with IntUitive RElaxometry) provides a versatile turbo spin-echo (TSE) platform for simultaneous morphologic and quantitative joint imaging. Two MIXTURE sequences were designed along clinical requirements: “MIX1”, combining proton density (PD)-weighted fat-saturated (FS) images and T2 mapping (acquisition time: 4:59 min), and “MIX2”, combining T1-weighted images and T1ρ mapping (6:38 min). MIXTURE sequences and their reference 2D and 3D TSE counterparts were acquired from ten human cadaveric knee joints at 3.0 T. Contrast, contrast-to-noise ratios, and coefficients of variation were comparatively evaluated using parametric tests. Clinical radiologists (n = 3) assessed diagnostic quality as a function of sequence and anatomic structure using five-point Likert scales and ordinal regression, with a significance level of α = 0.01. MIX1 and MIX2 had at least equal diagnostic quality compared to reference sequences of the same image weighting. Contrast, contrast-to-noise ratios, and coefficients of variation were largely similar for the PD-weighted FS and T1-weighted images. In clinically feasible scan times, MIXTURE sequences yield morphologic, TSE-based images of diagnostic quality and quantitative parameter maps with additional insights on soft tissue composition and ultrastructure.


  • No pressure, no diamonds? - Static vs. dynamic compressive in-situ loading to evaluate human articular cartilage functionality by functional MRI

    by Daniel Truhn, Ken Tonio Zwingenberger, Justus Schock, Daniel Benjamin Abrar, Karl Ludger Radke, Manuel Post, Kevin Linka, Matthias Knobe, Christiane Kuhl, Sven Nebelung


  • Accuracy of Chest CT for Differentiating COVID-19 from COVID-19 Mimics

    by Marwin-Jonathan Sähn, Can Yüksel, Sebastian Keil, Marcel P. Zeisberger, Manuel Post, Michael Kleines, Jörg Christian Brokmann, Christian Hübel, Christiane K. Kuhl, Peter Isfort, et al.

    Purpose To determine the performance of radiologists with different levels of expertise regarding the differentiation of COVID-19 from other atypical pneumonias. Chest CT to identify patients suffering from COVID-19 has been reported to be limited by its low specificity for distinguishing COVID-19 from other atypical pneumonias (“COVID-19 mimics”). Meanwhile, the understanding of the morphologic patterns of COVID-19 has improved and they appear to be fairly specific. Materials and Methods Between 02/2020 and 04/2020, 60 patients with COVID-19 pneumonia underwent chest CT in our department. Cases were matched with a comparable control group of 60 patients of similar age, sex, and comorbidities, who underwent chest CT prior to 01/2020 for atypical pneumonia caused by other pathogens. Included were other viral, fungal, and bacterial pathogens. All 120 cases were blinded to patient history and were reviewed independently by two radiologists and two radiology residents. Readers rated the probability of COVID-19 pneumonia according to the COV-RADS classification system. Results were analyzed using Clopper-Pearson 95 % confidence intervals, Youden’s Index for test quality criteria, and Fleiss‘ kappa statistics. Results Overall, readers were able to correctly identify the presence of COVID-19 pneumonia in 219/240 (sensitivity: 91 %; 95 %-CI; 86.9 %–94.5 %), and to correctly attribute CT findings to COVID-19 mimics in 159/240 ratings (specificity: 66.3 %; 59.9 %–72.2 %), yielding an overall diagnostic accuracy of 78.8 % (378/480; 74.8 %–82.3 %). Individual reader accuracy ranged from 74.2 % (89/120) to 84.2 % (101/120) and did not correlate significantly with reader expertise. Youden’s Index was 0.57. Between-reader agreement was moderate (κ = 0.53). Conclusion In this enriched cohort, radiologists were able to distinguish COVID-19 from “COVID-19 mimics” with moderate diagnostic accuracy. Accuracy did not correlate with reader expertise. Key Points: Citation Format


  • Open Access

    Longitudinal T2 Mapping and Texture Feature Analysis in the Detection and Monitoring of Experimental Post-Traumatic Cartilage Degeneration

    by Marc Sebastian Huppertz, Justus Schock, Karl Ludger Radke, Daniel Benjamin Abrar, Manuel Post, Christiane Kuhl, Daniel Truhn, Sven Nebelung

    Background: Traumatic cartilage injuries predispose articulating joints to focal cartilage defects and, eventually, posttraumatic osteoarthritis. Current clinical-standard imaging modalities such as morphologic MRI fail to reliably detect cartilage trauma and to monitor associated posttraumatic degenerative changes with oftentimes severe prognostic implications. Quantitative MRI techniques such as T2 mapping are promising in detecting and monitoring such changes yet lack sufficient validation in controlled basic research contexts. Material and Methods: 35 macroscopically intact cartilage samples obtained from total joint replacements were exposed to standardized injurious impaction with low (0.49 J, n = 14) or high (0.98 J, n = 14) energy levels and imaged before and immediately, 24 h, and 72 h after impaction by T2 mapping. Contrast, homogeneity, energy, and variance were quantified as features of texture on each T2 map. Unimpacted controls (n = 7) and histologic assessment served as reference. Results: As a function of impaction energy and time, absolute T2 values, contrast, and variance were significantly increased, while homogeneity and energy were significantly decreased. Conclusion: T2 mapping and texture feature analysis are sensitive diagnostic means to detect and monitor traumatic impaction injuries of cartilage and associated posttraumatic degenerative changes and may be used to assess cartilage after trauma to identify “cartilage at risk”.


  • Automated Analysis of Alignment in Long-Leg Radiographs by Using a Fully Automated Support System Based on Artificial Intelligence

    by Justus Schock, Daniel Truhn, Daniel B. Abrar, Dorit Merhof, Stefan Conrad, Manuel Post, Felix Mittelstrass, Christiane Kuhl, Sven Nebelung

    “Just Accepted” papers have undergone full peer review and have been accepted for publication in Radiology: Artificial Intelligence. This article will undergo copyediting, layout, and proof review ...


  • Identifying the imaging correlates of cartilage functionality based on quantitative MRI mapping - The collagenase exposure model

    by Tobias Hafner, Manuel Post, Oliver Said, Philipp Schad, Justus Schock, Daniel Benjamin Abrar, Matthias Knobe, Christiane Kuhl, Daniel Truhn, Sven Nebelung


  • Human articular cartilage mechanosensitivity is related to histological degeneration – a functional MRI study

    by S. Nebelung, M. Post, M. Knobe, D. Shah, C. Schleich, L. Hitpass, C. Kuhl, J. Thüring, D. Truhn


  • Open Access

    Detection of Early-Stage Degeneration in Human Articular Cartilage by Multiparametric MR Imaging Mapping of Tissue Functionality

    by Sven Nebelung, Manuel Post, Matthias Knobe, Markus Tingart, Pieter Emans, Johannes Thüring, Christiane Kuhl, Daniel Truhn

    To assess human articular cartilage tissue functionality by serial multiparametric quantitative MRI (qMRI) mapping as a function of histological degeneration. Forty-nine cartilage samples obtained during total knee replacement surgeries were placed in a standardized artificial knee joint within an MRI-compatible compressive loading device and imaged in situ and at three loading positions, i.e. unloaded, at 2.5 mm displacement (20% body weight [BW]) and at 5 mm displacement (110% BW). Using a clinical 3.0 T MRI system (Achieva, Philips), serial T1, T1ρ, T2 and T2* maps were generated for each sample and loading position. Histology (Mankin scoring) and biomechanics (Young’s modulus) served as references. Samples were dichotomized as intact (int, n = 27) or early degenerative (deg, n = 22) based on histology and analyzed using repeated-measures ANOVA and unpaired Student’s t-tests after log-transformation. For T1ρ, T2 and T2*, significant loading-induced differences were found in deg (in contrast to int) samples, while for T1 significant decreases in all zones were observed, irrespective of degeneration. In conclusion, cartilage functionality may be visualized using serial qMRI parameter mapping and the response-to-loading patterns are associated with histological degeneration. Hence, loading-induced changes in qMRI parameter maps provide promising surrogate parameters of tissue functionality and status in health and disease.


  • Functional in situ assessment of human articular cartilage using MRI: a whole-knee joint loading device

    by Sven Nebelung, Manuel Post, Stefan Raith, Horst Fischer, Matthias Knobe, Benedikt Braun, Andreas Prescher, Markus Tingart, Johannes Thüring, Philipp Bruners, et al.

    The response to loading of human articular cartilage as assessed by magnetic resonance imaging (MRI) remains to be defined in relation to histology and bio


  • Functional and biochemical assessment of postpreservation lung viability in a rat model

    by K. N. DeCampos, T. K. Waddell, A. S. Slutsky, Y. Wang, X. Wang, M. Post, G. A. Patterson

    We examined the relationship between DNA synthesis and postpreservation lung hemodynamics and gas exchange. Adult male Wistar rats (n = 168) were randomly allocated into seven groups (n = 24) according to the pulmonary vascular flush used [EuroCollins (EC), saline, or no flush] and to the temperature of flush and storage (4, 21, or 37 degrees C). In each group, lungs were stored for four different time periods (0–24 h). After storage, incorporation of [3H]-thymidine into DNA was measured in the right lung, and in 72 rats the left lung was reperfused for 1 h with venous blood in an ex vivo paracorporeal rat lung system. Autoradiography of EC lungs revealed that alveolar macrophages and epithelial cells were the two major cell types synthesizing DNA during ischemia. Gas exchange after preservation with EC was universally poor. In unflushed and saline-flushed lungs, a critical threshold for viability was detected beyond which DNA synthesis and lung effluent PO2 decreased more rapidly at higher storage temperatures. A positive correlation was found between the final lung effluent PO2 and [3H]thymidine uptake (R2 = 0.62; P < 0.0001). In this model, deoxyribonucleic acid synthesis was a good index of postpreservation hemodynamics and gas exchange function.