Chiara Suardi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chiara Suardi has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Sandra Pfanner
Hand and Reconstructive Microsurgery Unit, AOU Careggi, Florence, Italy
6 shared publications- Andrea Poggetti
Hand and Reconstructive Microsurgery Unit, AOU Careggi, 50134 Florence, Italy
5 shared publications Andrea Poggetti
Hand and Reconstructive Microsurgery Unit, AOU Careggi, Florence, Italy
4 shared publications- Giulio Lauri
Hand and Reconstructive Microsurgery Unit, AOU Careggi, 50134 Florence, Italy
2 shared publications - Prospero Bigazzi
Hand Surgery and Reconstructive Microsurgery Unit, AOU Careggi, Padiglione 25 CTO Largo Brambilla 3, 50139 Florence, Italy
2 shared publications - Sandra Pfanner
Hand and Microsurgery Department, University of Florence, Florence, Italy
2 shared publications
Latest Publications
- Open Access
The Modified Orbay Approach: A New Perspective to Obtain Better Exposure of the Radial Styloid
Background: The Orbay approach to volar distal radius described a volar zig-zag incision across the wrist crease, allowing a more distal exposure than traditional approaches. This adaptation enhances mobilization of the proximal radial fragment and improves visualization of both the articular surface and dorsally displaced distal radius fractures. Methods: In the present paper, we propose a further modification of the volar zig-zag approach, positioning the apex of the incision at the level of the radial styloid. Results: This modification aims to improve visualization of the radial styloid, the articular comminution, and the dorsal aspect of the distal radius, thereby optimizing fracture exposure and reduction. Conclusions: The principal advantage lies in the reduced need for traction along the radial margin of the incision to achieve adequate visualization and the avoidance of crossing the wrist crease, thereby preventing the formation of unsightly or adherent scars.
Open AccessThe Modified Orbay Approach: A New Perspective to Obtain Better Exposure of the Radial Styloid
Background: The Orbay approach to volar distal radius described a volar zig-zag incision across the wrist crease, allowing a more distal exposure than traditional approaches. This adaptation enhances mobilization of the proximal radial fragment and improves visualization of both the articular surface and dorsally displaced distal radius fractures. Methods: In the present paper, we propose a further modification of the volar zig-zag approach, positioning the apex of the incision at the level of the radial styloid. Results: This modification aims to improve visualization of the radial styloid, the articular comminution, and the dorsal aspect of the distal radius, thereby optimizing fracture exposure and reduction. Conclusions: The principal advantage lies in the reduced need for traction along the radial margin of the incision to achieve adequate visualization and the avoidance of crossing the wrist crease, thereby preventing the formation of unsightly or adherent scars.
- Open Access
- 23 May 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (11) , 3653
Comparison of the Isometric Position of the External Elbow Fixator: Self-Centering Versus Traditional Techniques, Postoperative CT Evaluation, and 3D Motion Analysis
Background/Objectives: The external hinged elbow fixator is a surgical choice both in the case of simple dislocations and elbow dislocation fractures. The correct positioning with respect to the elbow’s center of rotation is demanding. Authors developed a self-centering external fixator that does not require a pin in the elbow’s center of rotation. The aim of this study was to analyze the margin of error in its positioning. Methods: We subjected 16 patients to a CT-3D study reconstruction using 3D motion software to analyze the divergence angle and offset between the elbow’s center of rotation and that of the external fixator. The results were compared to those published on traditional implants. Results: All elbows were correctly reduced without re-dislocation. The average distance was 2° in relation to the center of rotation in the antero-posterior view, 3° in the cranio-caudal, and 2° in the medio-lateral. The divergence angle was 3.5° (min 0.4°; max 9.3°) and the offset 6.8 mm (min 0.06; max 17.5). The average range of motion was 10–145 (range 0–155). Discussion: The traditional hinged elbow external fixator creates severe complexity for surgeons in the necessary positioning of the elbow axial rod to correctly align the implant. The self-centering device avoids this step, making the procedure faster and easier. Although the alignment is still not perfect, the results are still comparable with traditional devices. Conclusions: The self-centering external fixator allows for correct alignment with the elbow’s center of rotation. It is less invasive and simpler, with a shorter learning curve, faster operating time, and less radiographic exposure.
- 23 May 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (11) , 3653
Open AccessComparison of the Isometric Position of the External Elbow Fixator: Self-Centering Versus Traditional Techniques, Postoperative CT Evaluation, and 3D Motion Analysis
Background/Objectives: The external hinged elbow fixator is a surgical choice both in the case of simple dislocations and elbow dislocation fractures. The correct positioning with respect to the elbow’s center of rotation is demanding. Authors developed a self-centering external fixator that does not require a pin in the elbow’s center of rotation. The aim of this study was to analyze the margin of error in its positioning. Methods: We subjected 16 patients to a CT-3D study reconstruction using 3D motion software to analyze the divergence angle and offset between the elbow’s center of rotation and that of the external fixator. The results were compared to those published on traditional implants. Results: All elbows were correctly reduced without re-dislocation. The average distance was 2° in relation to the center of rotation in the antero-posterior view, 3° in the cranio-caudal, and 2° in the medio-lateral. The divergence angle was 3.5° (min 0.4°; max 9.3°) and the offset 6.8 mm (min 0.06; max 17.5). The average range of motion was 10–145 (range 0–155). Discussion: The traditional hinged elbow external fixator creates severe complexity for surgeons in the necessary positioning of the elbow axial rod to correctly align the implant. The self-centering device avoids this step, making the procedure faster and easier. Although the alignment is still not perfect, the results are still comparable with traditional devices. Conclusions: The self-centering external fixator allows for correct alignment with the elbow’s center of rotation. It is less invasive and simpler, with a shorter learning curve, faster operating time, and less radiographic exposure.
- 8 March 2025
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 65, 102956
Closed avulsion of flexor digitorum profundus of the ring finger: Does the surgical technique really change the outcome?
- 8 March 2025
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 65, 102956
Closed avulsion of flexor digitorum profundus of the ring finger: Does the surgical technique really change the outcome?
- Open Access
- 29 June 2024
- Published by Elsevier in Journal of Orthopaedic Reports
- Vol. 4 (3)
Chat-GPT adequate response to FAQs about thumb arthritis
- 29 June 2024
- Published by Elsevier in Journal of Orthopaedic Reports
- Vol. 4 (3)
Open AccessChat-GPT adequate response to FAQs about thumb arthritis
- 28 June 2024
- Published by Elsevier in Revue de Chirurgie Orthopédique et Traumatologique
- Vol. 110 (5) , 754-759
Fixation squelettique dans une main mutilée – Fixation par broche de Kirschner ou par vis sans tête intramédullaire
- 28 June 2024
- Published by Elsevier in Revue de Chirurgie Orthopédique et Traumatologique
- Vol. 110 (5) , 754-759
Fixation squelettique dans une main mutilée – Fixation par broche de Kirschner ou par vis sans tête intramédullaire
- 21 May 2024
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 43 (4) , 101721
Tissue-sparing approach for partial carpal fusion
- 21 May 2024
- Published by Elsevier in Hand Surgery and Rehabilitation
- Vol. 43 (4) , 101721
Tissue-sparing approach for partial carpal fusion
- 13 May 2024
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 94, 157-159
Four corner fusion: Comparison between dorsal circular plate and compression screws
- 13 May 2024
- Published by Elsevier in Journal of Plastic, Reconstructive & Aesthetic Surgery
- Vol. 94, 157-159
Four corner fusion: Comparison between dorsal circular plate and compression screws
Choosing the proper implant for extra-articular fractures of proximal phalanges: A study on 75 cases
- Open Access
- 3 June 2022
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 17 (1) , 1-7
Varus morphology and its surgical implication in osteoarthritic knee and total knee arthroplasty
Background: Knee varus alignment represents a notorious cause of knee osteoarthritis. It can be caused by tibial deformity, combined tibial–femoral deformity and/or ligament imbalance. Understanding malalignment is crucial in total knee arthroplasty to restore frontal plane neutral mechanical axis. The aim of this study was to determine which factor contributes the most to varus osteoarthritic knee and its related surgical implications in performing a total knee arthroplasty. Methods: We retrospectively evaluated 140 patients operated for total knee arthroplasty due to a varus knee. Full-leg hip to ankle preoperative X-rays were taken. Radiological parameters recorded were: mechanical axis deviation, hip–knee–ankle, anatomical–mechanical angle, medial neck shaft angle, mechanical lateral distal femoral angle (mLDFA), medial proximal tibial angle (MPTA), joint line convergence angle (JLCA), lateral proximal femoral angle, lateral distal tibial angle (LDTA), femoral bowing, and length of tibia and femur. We also determined ideals tibial and femoral cuts in mm according to mechanical alignment technique. A R2 was calculated based on the linear regression between the predicted values and the observed data. Results: The greatest contributor to arthritic varus (R = 0.444) was MPTA. Minor contributors were mLDFA (R = 0.076), JLCA (R = 0.1554), LDTA (R = 0.065), and femoral bowing (R = 0.049). We recorded an average of 7.6 mm in lateral tibial cut thickness to restore neutral alignment. Conclusions: The radiological major contributor to osteoarthritic varus knee alignment is related to proximal tibia deformity. As a surgical consequence, during performing total knee arthroplasty, the majority of the correction should therefore be made on tibial cut.
- 3 June 2022
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 17 (1) , 1-7
Open AccessVarus morphology and its surgical implication in osteoarthritic knee and total knee arthroplasty
Background: Knee varus alignment represents a notorious cause of knee osteoarthritis. It can be caused by tibial deformity, combined tibial–femoral deformity and/or ligament imbalance. Understanding malalignment is crucial in total knee arthroplasty to restore frontal plane neutral mechanical axis. The aim of this study was to determine which factor contributes the most to varus osteoarthritic knee and its related surgical implications in performing a total knee arthroplasty. Methods: We retrospectively evaluated 140 patients operated for total knee arthroplasty due to a varus knee. Full-leg hip to ankle preoperative X-rays were taken. Radiological parameters recorded were: mechanical axis deviation, hip–knee–ankle, anatomical–mechanical angle, medial neck shaft angle, mechanical lateral distal femoral angle (mLDFA), medial proximal tibial angle (MPTA), joint line convergence angle (JLCA), lateral proximal femoral angle, lateral distal tibial angle (LDTA), femoral bowing, and length of tibia and femur. We also determined ideals tibial and femoral cuts in mm according to mechanical alignment technique. A R2 was calculated based on the linear regression between the predicted values and the observed data. Results: The greatest contributor to arthritic varus (R = 0.444) was MPTA. Minor contributors were mLDFA (R = 0.076), JLCA (R = 0.1554), LDTA (R = 0.065), and femoral bowing (R = 0.049). We recorded an average of 7.6 mm in lateral tibial cut thickness to restore neutral alignment. Conclusions: The radiological major contributor to osteoarthritic varus knee alignment is related to proximal tibia deformity. As a surgical consequence, during performing total knee arthroplasty, the majority of the correction should therefore be made on tibial cut.