Miguel Piñón
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Miguel Piñón has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
Gonzalo Pradas
Department of Cardiac Surgery, Complejo Hospitalario Universitario de Vigo, Vigo, Spain
5 shared publications- Andrea Colli
Cardiac Surgery Unit, Department of Surgical, Medical and Molecular Pathology and Critical Care, University of Pisa, Pisa, Italy
3 shared publications - Andreas Zierer
Department for Cardiothoracic and Vascular Surgery, Johannes Kepler University Linz, Kepler University Hospital GmbH, 4020 Linz, Austria
3 shared publications Beatriz Acuña
Department of Cardiac Surgery, Complejo Hospitalario Universitario de Vigo, Vigo, Spain
3 shared publications- Christophe Dubois
Department of Cardiovascular Sciences, KU Leuven , Herestraat 49, Leuven 3000
3 shared publications Daniel Molina
3 shared publications
Latest Publications
- Open Access
- 23 September 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (19) , 7400
Artificial Intelligence-Derived Computed Tomography Phenotyping for Cardiovascular Risk Stratification in Transcatheter Mitral Valve Replacement
Background: Despite high procedural success of transcatheter mitral valve replacement (TMVR), mortality remains substantial, and conventional risk scores inadequately reflect the specific risk profile of this high-risk population. Artificial intelligence (AI)-derived analysis may enable TMVR-specific risk assessment using routinely acquired computed tomography (CT). Methods: In a retrospective European multicenter registry, AI-based segmentation of harmonized real-world pre-procedural cardiac CT with variable thoracic and upper-abdominal coverage was applied in patients undergoing TMVR with the TendyneTM system (134 patients; 346 CT-derived variables retained for high-dimensional screening). One-year cardiovascular mortality was assessed using Cox proportional hazards models with Benjamini–Hochberg false discovery rate correction. STS- and EuroSCORE II-adjusted analyses and a targeted coronary-ventricular coupling analysis were performed. Results: In the STS-adjusted Cox analysis, nine AI-derived CT parameters met the 10% FDR discovery threshold for cardiovascular mortality, spanning skeletal (n = 3), muscular (n = 1), and cardiopulmonary phenotypes (n = 5), whereas three parameters met this threshold in CT-only analyses. Coronary–ventricular coupling, defined as coronary artery volume relative to left ventricular end-diastolic volume, was significantly associated with lower 1-year cardiovascular mortality in the CT-only analysis (HR per IQR 0.47, 95% CI 0.22–1.00; p = 0.049) and after EuroSCORE II adjustment (HR 0.47, 95% CI 0.22–0.99; p = 0.046), while the STS-adjusted estimate remained directionally consistent but did not reach statistical significance (HR 0.49, 95% CI 0.23–1.05; p = 0.067). Conclusions: AI-based CT phenotyping identifies imaging-derived markers associated with cardiovascular mortality beyond information captured by conventional surgical risk scores in TMVR patients. Coronary-ventricular coupling emerges as a promising automated CT-derived imaging marker with a biologically plausible pathophysiological basis, linking coronary arterial volume to ventricular size in mitral valve disease.
- 23 September 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (19) , 7400
Open AccessArtificial Intelligence-Derived Computed Tomography Phenotyping for Cardiovascular Risk Stratification in Transcatheter Mitral Valve Replacement
Background: Despite high procedural success of transcatheter mitral valve replacement (TMVR), mortality remains substantial, and conventional risk scores inadequately reflect the specific risk profile of this high-risk population. Artificial intelligence (AI)-derived analysis may enable TMVR-specific risk assessment using routinely acquired computed tomography (CT). Methods: In a retrospective European multicenter registry, AI-based segmentation of harmonized real-world pre-procedural cardiac CT with variable thoracic and upper-abdominal coverage was applied in patients undergoing TMVR with the TendyneTM system (134 patients; 346 CT-derived variables retained for high-dimensional screening). One-year cardiovascular mortality was assessed using Cox proportional hazards models with Benjamini–Hochberg false discovery rate correction. STS- and EuroSCORE II-adjusted analyses and a targeted coronary-ventricular coupling analysis were performed. Results: In the STS-adjusted Cox analysis, nine AI-derived CT parameters met the 10% FDR discovery threshold for cardiovascular mortality, spanning skeletal (n = 3), muscular (n = 1), and cardiopulmonary phenotypes (n = 5), whereas three parameters met this threshold in CT-only analyses. Coronary–ventricular coupling, defined as coronary artery volume relative to left ventricular end-diastolic volume, was significantly associated with lower 1-year cardiovascular mortality in the CT-only analysis (HR per IQR 0.47, 95% CI 0.22–1.00; p = 0.049) and after EuroSCORE II adjustment (HR 0.47, 95% CI 0.22–0.99; p = 0.046), while the STS-adjusted estimate remained directionally consistent but did not reach statistical significance (HR 0.49, 95% CI 0.23–1.05; p = 0.067). Conclusions: AI-based CT phenotyping identifies imaging-derived markers associated with cardiovascular mortality beyond information captured by conventional surgical risk scores in TMVR patients. Coronary-ventricular coupling emerges as a promising automated CT-derived imaging marker with a biologically plausible pathophysiological basis, linking coronary arterial volume to ventricular size in mitral valve disease.
- Open Access
- 31 March 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (7) , 2660
Prognostic Impact of Qualitative and Quantitative Mitral Valve Calcification in Transapical Transcatheter Mitral Valve Replacement: A Sub-Analysis of the TENDER Registry
Objectives: This study aims to review short- to intermediate-term outcomes after transapical transcatheter mitral valve replacement (TMVR) using the Tendyne valve system in patients with mitral annular calcification (MAC), including off-label use in severe MAC. Methods: This retrospective sub-analysis of the multicenter Tendyne European Experience (TENDER) registry included fifty-three MAC patients who underwent commercial Tendyne-TMVR in 15 European heart centers between 01/2020 and 06/2022. Patients were assigned to the mild (n = 16), moderate (n = 17), and severe MAC (n = 20) cohorts according to Guerrero’s MAC score. Additionally, the predictive value of detailed computed tomography-derived, quantitative, and qualitative MAC characteristics on clinical outcome was tested. Results: In this overall multimorbid patient population, predominantly treated for severe mitral regurgitation (MR), technical success rates were comparable among cohorts (mild MAC: 93.8% vs. moderate MAC: 88.2%vs. severe MAC: 95%, p = 0.720). Complete MR abolishment was achieved in 88.7% of patients, with no significant difference between cohorts in the incidence of residual MR >1+ (n = 1 in moderate MAC; p = 0.350) or paravalvular leakage >1+ (PVL; n = 2 in moderate MAC, p = 0.118) at discharge. All three in-hospital deaths occurred in patients with moderate MAC (p = 0.034). There were no significant differences in 1-year cardiovascular mortality (mild MAC: 23.1% vs. moderate MAC: 6.3% vs. severe MAC: 0%, p = 0.085) and overall mortality (mild MAC: 38.5% vs. moderate MAC: 43.8% vs. severe MAC: 18.8%, p = 0.291) between the cohorts, including in patients with off-label severe MAC. The rate of heart failure hospitalization at 1 year was significantly higher in the moderate MAC cohort (mild MAC: 10% vs. moderate MAC: 61.5%, severe MAC: 21.4%, p = 0.017). Further quantitative and qualitative MAC parameters showed no significant impact on 1-year survival or hemodynamic prosthetic performance. Conclusions: This MAC-focused analysis suggests that Valve-in-MAC using the Tendyne valve system is safe, technically feasible, and associated with satisfying hemodynamic and clinical outcomes, irrespective of MAC morphology.
- 31 March 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (7) , 2660
Open AccessPrognostic Impact of Qualitative and Quantitative Mitral Valve Calcification in Transapical Transcatheter Mitral Valve Replacement: A Sub-Analysis of the TENDER Registry
Objectives: This study aims to review short- to intermediate-term outcomes after transapical transcatheter mitral valve replacement (TMVR) using the Tendyne valve system in patients with mitral annular calcification (MAC), including off-label use in severe MAC. Methods: This retrospective sub-analysis of the multicenter Tendyne European Experience (TENDER) registry included fifty-three MAC patients who underwent commercial Tendyne-TMVR in 15 European heart centers between 01/2020 and 06/2022. Patients were assigned to the mild (n = 16), moderate (n = 17), and severe MAC (n = 20) cohorts according to Guerrero’s MAC score. Additionally, the predictive value of detailed computed tomography-derived, quantitative, and qualitative MAC characteristics on clinical outcome was tested. Results: In this overall multimorbid patient population, predominantly treated for severe mitral regurgitation (MR), technical success rates were comparable among cohorts (mild MAC: 93.8% vs. moderate MAC: 88.2%vs. severe MAC: 95%, p = 0.720). Complete MR abolishment was achieved in 88.7% of patients, with no significant difference between cohorts in the incidence of residual MR >1+ (n = 1 in moderate MAC; p = 0.350) or paravalvular leakage >1+ (PVL; n = 2 in moderate MAC, p = 0.118) at discharge. All three in-hospital deaths occurred in patients with moderate MAC (p = 0.034). There were no significant differences in 1-year cardiovascular mortality (mild MAC: 23.1% vs. moderate MAC: 6.3% vs. severe MAC: 0%, p = 0.085) and overall mortality (mild MAC: 38.5% vs. moderate MAC: 43.8% vs. severe MAC: 18.8%, p = 0.291) between the cohorts, including in patients with off-label severe MAC. The rate of heart failure hospitalization at 1 year was significantly higher in the moderate MAC cohort (mild MAC: 10% vs. moderate MAC: 61.5%, severe MAC: 21.4%, p = 0.017). Further quantitative and qualitative MAC parameters showed no significant impact on 1-year survival or hemodynamic prosthetic performance. Conclusions: This MAC-focused analysis suggests that Valve-in-MAC using the Tendyne valve system is safe, technically feasible, and associated with satisfying hemodynamic and clinical outcomes, irrespective of MAC morphology.
- Open Access
- 20 June 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (13) , 4412
An Imaging-Based Marker to Refine Risk Stratification for Transcatheter Mitral Valve Replacement
Background: The Tendyne™ transcatheter heart valve (THV) system is a promising option for high-risk patients with severe mitral regurgitation (MR) who are ineligible for surgery or transcatheter edge-to-edge repair (TEER). As most fatal complications occur within the first 90 days, this study aimed to identify anatomical predictors of in-hospital mortality after transcatheter mitral valve replacement (TMVR). Methods: In this subanalysis of the TENDER registry, data from 110 patients who underwent TMVR across 26 centers between January 2020 and June 2022 were evaluated. Preprocedural imaging parameters were analyzed, including transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and cardiac 4D computed tomography (CT). Results: We identified LVEDDi as a significant predictor of in-hospital mortality (p = 0.022), with lower values in non-survivors (26.42 ± 3.76 mm/m2) than in survivors (30.37 ± 5.58 mm/m2). Both indexed and absolute LVEDDi predicted in-hospital complications (p < 0.001 and p = 0.008). In multivariate analysis, LVEDDi (p = 0.048; OR = 0.856) and STS score (p = 0.038; OR = 1.114) remained independent predictors of in-hospital mortality. In an extended model, only LVEDDi persisted as a significant predictor (p = 0.007), highlighting its robustness. Conclusions: This analysis identified a small LVEDDi as a novel, clinically relevant risk factor in TMVR and showed its added value alongside conventional markers. Its easy calculation supports incorporating LVEDDi thresholds into screening to improve patient selection and outcomes.
- 20 June 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (13) , 4412
Open AccessAn Imaging-Based Marker to Refine Risk Stratification for Transcatheter Mitral Valve Replacement
Background: The Tendyne™ transcatheter heart valve (THV) system is a promising option for high-risk patients with severe mitral regurgitation (MR) who are ineligible for surgery or transcatheter edge-to-edge repair (TEER). As most fatal complications occur within the first 90 days, this study aimed to identify anatomical predictors of in-hospital mortality after transcatheter mitral valve replacement (TMVR). Methods: In this subanalysis of the TENDER registry, data from 110 patients who underwent TMVR across 26 centers between January 2020 and June 2022 were evaluated. Preprocedural imaging parameters were analyzed, including transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and cardiac 4D computed tomography (CT). Results: We identified LVEDDi as a significant predictor of in-hospital mortality (p = 0.022), with lower values in non-survivors (26.42 ± 3.76 mm/m2) than in survivors (30.37 ± 5.58 mm/m2). Both indexed and absolute LVEDDi predicted in-hospital complications (p < 0.001 and p = 0.008). In multivariate analysis, LVEDDi (p = 0.048; OR = 0.856) and STS score (p = 0.038; OR = 1.114) remained independent predictors of in-hospital mortality. In an extended model, only LVEDDi persisted as a significant predictor (p = 0.007), highlighting its robustness. Conclusions: This analysis identified a small LVEDDi as a novel, clinically relevant risk factor in TMVR and showed its added value alongside conventional markers. Its easy calculation supports incorporating LVEDDi thresholds into screening to improve patient selection and outcomes.
- 5 December 2023
- Published by SAGE Publications in Perfusion
- Vol. 40 (1) , 243-246
Successful implementation of prophylactic veno-venoarterial extracorporeal membrane oxygenation in high-risk trauma surgery: A case report
Introduction: Extracorporeal Membrane Oxygenation (ECMO) is increasingly utilized in trauma care, yet its elective use during high-risk surgeries remains unreported. Case Report: We report a successful instance of prophylactic ECMO support via a Veno-Venoarterial (V-VA) configuration during high-risk surgery in a patient with extensive trauma, including severe thoracic damage and a highly unstable thoracic spine fracture. V-VA ECMO prevented complications such as hemodynamic and respiratory collapse associated with chest compression during the surgical procedure, as the patient should be in a prone position. Discussion: The potential of ECMO as prophylactic support in high-risk surgery amongst trauma patients underscores a novel application of this technology. Complex configurations must be evaluated to avoid associated ECMO complications. Conclusion: Our case highlights the potential of prophylactic ECMO hybrid modes, indicating their safe application during high-risk procedures in select trauma patients.
- 5 December 2023
- Published by SAGE Publications in Perfusion
- Vol. 40 (1) , 243-246
Successful implementation of prophylactic veno-venoarterial extracorporeal membrane oxygenation in high-risk trauma surgery: A case report
Introduction: Extracorporeal Membrane Oxygenation (ECMO) is increasingly utilized in trauma care, yet its elective use during high-risk surgeries remains unreported. Case Report: We report a successful instance of prophylactic ECMO support via a Veno-Venoarterial (V-VA) configuration during high-risk surgery in a patient with extensive trauma, including severe thoracic damage and a highly unstable thoracic spine fracture. V-VA ECMO prevented complications such as hemodynamic and respiratory collapse associated with chest compression during the surgical procedure, as the patient should be in a prone position. Discussion: The potential of ECMO as prophylactic support in high-risk surgery amongst trauma patients underscores a novel application of this technology. Complex configurations must be evaluated to avoid associated ECMO complications. Conclusion: Our case highlights the potential of prophylactic ECMO hybrid modes, indicating their safe application during high-risk procedures in select trauma patients.
- 22 March 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (2) , e22-e26
Usefulness of Self-Expanding Drainage Cannula in Venovenous Extracorporeal Membrane Oxygenation: Tips, Tricks, and Results of an Early Experience
Inadequate venous drainage decreases the efficiency of extracorporeal membrane oxygenation (ECMO). Pump augmentation may even make it worse due to collapse of the venous system under negative pressures. Furthermore, recirculation is a phenomenon that occurs when oxygenated blood supplied through the infusion cannula is withdrawn directly through the drainage cannula without contributing to the oxygenation of the patient and also compromises the efficacy of the therapy. Large drainage cannulas allow for similar flow rates at lower pump speed. But percutaneous insertion of these larger cannulas could be challenging. When using a self-expandable cannula, the diameter of the cannula for the insertion can be reduced, and once inserted, its intravascular diameter maximized, resulting in a large venous cannula due to in situ expansion after mandrel removal (up to 36F). We present a retrospective series of selfexpanding venous cannula 430 or 530 mm in length in six consecutive patients undergoing venovenous (VV) ECMO. No vascular or cardiac iatrogenic injury was caused during implantation. Target flows were reached, and no clinically significant recirculation was described in any case. The use of selfexpanding drainage cannulas was safe, and efficient drainage was achieved with easy and definitive unique positioning during cannulation.
- 22 March 2021
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 68 (2) , e22-e26
Usefulness of Self-Expanding Drainage Cannula in Venovenous Extracorporeal Membrane Oxygenation: Tips, Tricks, and Results of an Early Experience
Inadequate venous drainage decreases the efficiency of extracorporeal membrane oxygenation (ECMO). Pump augmentation may even make it worse due to collapse of the venous system under negative pressures. Furthermore, recirculation is a phenomenon that occurs when oxygenated blood supplied through the infusion cannula is withdrawn directly through the drainage cannula without contributing to the oxygenation of the patient and also compromises the efficacy of the therapy. Large drainage cannulas allow for similar flow rates at lower pump speed. But percutaneous insertion of these larger cannulas could be challenging. When using a self-expandable cannula, the diameter of the cannula for the insertion can be reduced, and once inserted, its intravascular diameter maximized, resulting in a large venous cannula due to in situ expansion after mandrel removal (up to 36F). We present a retrospective series of selfexpanding venous cannula 430 or 530 mm in length in six consecutive patients undergoing venovenous (VV) ECMO. No vascular or cardiac iatrogenic injury was caused during implantation. Target flows were reached, and no clinically significant recirculation was described in any case. The use of selfexpanding drainage cannulas was safe, and efficient drainage was achieved with easy and definitive unique positioning during cannulation.
- Open Access
- 9 September 2020
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 36 (5) , 1624-1631
COVID 19—A Spanish perspective
Background COVID‐19 hit hard worldwide. There has been an impact on global activity of cardiac surgery. Spain has been one of the hardest hit countries with one of the highest per population incidences and death. Methods The following is an overview of the epidemiology and impact on resources, the caseload and surgical societal implemented recommendations, the description of the ECMO activity and nosocomial transmission among healthcare workers. Results There was a reduction of 5‐6 times of the regular caseload. As of July 17, 160 ECMO implants were performed. In a 13‐center survey, at least 1 staff surgeon had SARS‐COV‐19 infection. Conclusion Cardiac surgical activity has suffered a negative impact all over the country.
- 9 September 2020
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 36 (5) , 1624-1631
Open AccessCOVID 19—A Spanish perspective
Background COVID‐19 hit hard worldwide. There has been an impact on global activity of cardiac surgery. Spain has been one of the hardest hit countries with one of the highest per population incidences and death. Methods The following is an overview of the epidemiology and impact on resources, the caseload and surgical societal implemented recommendations, the description of the ECMO activity and nosocomial transmission among healthcare workers. Results There was a reduction of 5‐6 times of the regular caseload. As of July 17, 160 ECMO implants were performed. In a 13‐center survey, at least 1 staff surgeon had SARS‐COV‐19 infection. Conclusion Cardiac surgical activity has suffered a negative impact all over the country.
- Open Access
- 30 July 2020
- Published by Wiley
COVID 19 - The Spanish Perspective
COVID-19 hit hard worldwide. There has been an impact on global activity of cardiac surgery. Spain has been one of the hardest hit countries with one of the highest per population incidences and death. Cardiac surgical activity has suffered a negative impact all over the country. The following is an overview of the epidemiology and impact on resources, the caseload and surgical societal implemented recommendations, the description of the ECMO activity and nosocomial transmission among healthcare workers.
- 30 July 2020
- Published by Wiley
Open AccessCOVID 19 - The Spanish Perspective
COVID-19 hit hard worldwide. There has been an impact on global activity of cardiac surgery. Spain has been one of the hardest hit countries with one of the highest per population incidences and death. Cardiac surgical activity has suffered a negative impact all over the country. The following is an overview of the epidemiology and impact on resources, the caseload and surgical societal implemented recommendations, the description of the ECMO activity and nosocomial transmission among healthcare workers.
- 10 April 2019
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 29 (3) , 371-377
Frailty, disability and comorbidity: different domains lead to different effects after surgical aortic valve replacement in elderly patients
OBJECTIVES: Frailty syndrome predicts adverse outcomes after surgical aortic valve replacement. However, disability or comorbidity is frequently associated with preoperative frailty evaluation. The effects of these domains on early and late outcomes were analysed. METHODS: A prospective study including patients aged ≥75 years with symptomatic severe aortic stenosis who received aortic valve replacement with or without coronary artery bypass grafting was conducted. We used the Cardiovascular Health Study Frailty Phenotype to assess frailty, the Lawton–Brody index to define disability and the Charlson comorbidity index (CCI) to evaluate comorbidity. RESULTS: Frailty was identified in 57 (31%), dependence in 18 (9.9%) and advanced comorbidity (CCI ≥ 4) in 67 (36.6%) of the 183 enrolled patients. Operative mortality (1.6%), transfusion rate and duration of stay increased in patients with CCI ≥4 (P < 0.005). There was a non-significant trend for these adverse outcomes among the frail patients. Follow-up was achieved in all patients (median/interquartile range 869/699–1099 days). Kaplan–Meier univariable analysis showed a reduced survival rate for frail and dependent patients and for those with multiple comorbidities (P < 0.05). According to multivariable analysis, frailty and comorbidity were independent risk factors for 1-year mortality, while disability and comorbidity, but not frailty, were risk factors for 3-year mortality (P < 0.05). CONCLUSIONS: Surgical aortic valve replacement in patients aged ≥75 years is a safe procedure with low mortality rates. Operative outcomes are mainly affected by comorbidities. The main influence of survival occurs throughout the first year, and an improved functional status prevents any progression towards disabilities, which could potentially benefit long-term outcomes. Clinical trial registration number: NCT02745314
- 10 April 2019
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 29 (3) , 371-377
Frailty, disability and comorbidity: different domains lead to different effects after surgical aortic valve replacement in elderly patients
OBJECTIVES: Frailty syndrome predicts adverse outcomes after surgical aortic valve replacement. However, disability or comorbidity is frequently associated with preoperative frailty evaluation. The effects of these domains on early and late outcomes were analysed. METHODS: A prospective study including patients aged ≥75 years with symptomatic severe aortic stenosis who received aortic valve replacement with or without coronary artery bypass grafting was conducted. We used the Cardiovascular Health Study Frailty Phenotype to assess frailty, the Lawton–Brody index to define disability and the Charlson comorbidity index (CCI) to evaluate comorbidity. RESULTS: Frailty was identified in 57 (31%), dependence in 18 (9.9%) and advanced comorbidity (CCI ≥ 4) in 67 (36.6%) of the 183 enrolled patients. Operative mortality (1.6%), transfusion rate and duration of stay increased in patients with CCI ≥4 (P < 0.005). There was a non-significant trend for these adverse outcomes among the frail patients. Follow-up was achieved in all patients (median/interquartile range 869/699–1099 days). Kaplan–Meier univariable analysis showed a reduced survival rate for frail and dependent patients and for those with multiple comorbidities (P < 0.05). According to multivariable analysis, frailty and comorbidity were independent risk factors for 1-year mortality, while disability and comorbidity, but not frailty, were risk factors for 3-year mortality (P < 0.05). CONCLUSIONS: Surgical aortic valve replacement in patients aged ≥75 years is a safe procedure with low mortality rates. Operative outcomes are mainly affected by comorbidities. The main influence of survival occurs throughout the first year, and an improved functional status prevents any progression towards disabilities, which could potentially benefit long-term outcomes. Clinical trial registration number: NCT02745314
- Open Access
- 1 January 2019
- Published by Elsevier in Cirugía Cardiovascular
- Vol. 26 (1) , 52-58
Cirugía del síndrome aórtico agudo tipo A: seguimiento a 20 años
- 1 January 2019
- Published by Elsevier in Cirugía Cardiovascular
- Vol. 26 (1) , 52-58
Open AccessCirugía del síndrome aórtico agudo tipo A: seguimiento a 20 años