POPawel Okal

Pawel Okal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pawel Okal has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Experimental Analysis of Pressure Sensor Membranes Intended for Vacuum Arc-Extinguishing Chambers in Medium-Voltage Switching Devices

    by Paweł Węgierek, Damian Kostyła, Paweł Okal, Czesław Kozak

    This article presents a comparison of empirical and simulation studies and the parameters declared by the membrane manufacturer. The analysis concludes that these values differ at each stage. Therefore, a numerical and simulation analysis of an optimal flat membrane was undertaken, which will successfully perform measurement functions across the full pressure range without causing inelastic deformations based on a membrane made of 316 L stainless steel with the following mechanical parameters: Young’s modulus E=2×1011 Pa, Poisson’s ratio ν=0.28, density ρ=7980 kg/m3, and yield strength 2.8 × 108 Pa. A diaphragm with an outer diameter of 25.4 mm, an inner diameter of 2.22×10−4 m, and a thickness of t = 5.08×10−5 m was designed for a pressure sensor in vacuum extinguishing chambers of medium-voltage devices, with a pressure difference Δp from 7 × 10−4 Pa to 1.013 × 105 Pa. Finite element method (FEM) simulations in the COMSOL Multiphysics environment showed maximum von Mises reduced stresses 1.96 × 108 Pa below the yield strength, confirming operation in the linear-elastic range. The central deflection, described analytically by the equation y=3(1−ν2)Pr416Et3, increased fivefold with an increase in diameter to 3.81×10−2 m (active area A = 1.14 × 10−3 m2 compared to 5.07 × 10−4 m2), achieving a metrological sensitivity of 9.1 × 10−10 m/Pa. Experimental studies integrated with Bragg FBG and epoxy adhesive (E = 5 × 109 Pa, tensile strength 4.2×107 Pa) revealed a significant deviation from the manufacturer’s catalog data (e.g., deflection of 2.0×10−5 m at 6.89×102 Pa), resulting from uneven bonding and a lack of coaxiality. Corrugated membranes with t = 2.0×10−5 m exceeded plasticity, while the optimized configuration of a smooth membrane with rounded adhesive edges (R=1×10−4 m) enabled precise pressure monitoring below 10−1 Pa, despite technological restrictions on assembly and miniaturization.

  • Open Access

    Research on the Alternating Current Properties of Cellulose–Innovative Bio-Oil Nanocomposite as the Fundamental Component of Power Transformer Insulation—Determination of Nanodroplet Dimensions and the Distances Between Them

    by Konrad Kierczyński, Tomasz N. Kołtunowicz, Vitalii Bondariev, Paweł Okal, Marek Zenker, Marek Szrot, Paweł Molenda, Andrzej Cichoń, Paweł Żukowski

    The paper presents measurements of frequency dependence of conductivity and real components of complex permittivity of a nanocomposite consisting of electrical pressboard, bio-insulating oil and water nanodroplets with moisture content ranging from 0.6 wt.% to 5 wt.%. Bio-oil meets high environmental requirements—it is fully biodegradable, and its combustion products are significantly less harmful than those of mineral oil. In addition, the use of bio-oil reduces the carbon footprint of power transformer production. The quantum mechanical phenomenon of electron tunnelling between potential wells created by water nanodroplets was used to analyze the experimental results obtained. The study determined the effect of moisture content on the relative relaxation time values. On this basis, the number of water molecules in nanodroplets, their diameters and the concentration of nanodroplets depending on moisture content were determined. The distances over which electrons tunnel in moist pressboard impregnated with bio-oil were determined. These values are the expected values of the probability distribution of the distance between neighbouring nanodroplets. The values of the number of water molecules in nanodroplets are also the expected values of the probability distribution of the number of molecules in nanodroplets. It has been established that during many years of transformer life, several parallel processes occur as the moisture content in bio-oil-impregnated pressboard increases. One of them involves the accumulation of water molecules collected in the pressboard in nanodroplets. The second is an increase in the concentration of nanodroplets. The third is an increase in the average number of water molecules in nanodroplets.

  • Open Access

    Frequency–Temperature Characteristics of the Cellulose—Insulating Oil–Water Nanodroplet Nanocomposite Components for Diagnostic Evaluation of Power Transformer Insulation

    by Pawel Zukowski, Konrad Kierczynski, Przemyslaw Rogalski, Pawel Okal, Pawel Molenda, Marek Szrot, Rafal Pajak

    We determined the reference characteristics of the loss tangent and the real component of the complex permittivity of the cellulose-insulating oil–water nanodroplet nanocomposite with a moisture content of 5.17% by weight in pressboard. Such a high moisture content was selected because a value close to 5% by weight is critical, and reaching it may lead to catastrophic transformer failure as well as contamination of the natural environment with poorly biodegradable mineral oil and products of its incomplete combustion. Based on the measurement results, the values of the loss tangent and the real and imaginary components of the complex permittivity of the power transformer insulation system, consisting of moistened pressboard and insulating oil, were determined according to CIGRE. These values were obtained for both factory-new and moistened mineral oil. It was found that oil moisture content has a significant impact on the tanδ characteristics of strongly moistened liquid–solid insulation in the lowest frequency range. In the intermediate frequency range, this effect gradually decreases and then practically disappears. In the frequency range above 50 Hz, the tanδ values depend on the moisture content in cellulose and on the geometrical parameters of the insulation components in the CIGRE system, and do not depend on the oil moisture content. The influence of oil moisture on the estimation of cellulose moisture content becomes noticeable starting from a water content of 2% in pressboard. This should be taken into account in insulation condition analysis and in moisture level estimation in order to detect a critical state threatening catastrophic failure of a power transformer. It was also determined that the real component of the complex permittivity depends only weakly on oil moisture, and only in the low-temperature and low-frequency ranges. In contrast, the imaginary component of the complex permittivity depends on oil moisture practically in the same way as the loss tangent of the power transformer insulation system.


  • Open Access

    Study of AC Conductivity and Relaxation Times Depending on Moisture Content in Nanocomposites of Insulation Pressboard–Innovative Bio-Oil–Water Nanodroplets

    by Pawel Zukowski, Konrad Kierczynski, Pawel Okal, Marek Zenker, Rafal Pajak, Marek Szrot, Pawel Molenda, Tomasz N. Koltunowicz

    The aim of this study was to determine the frequency–temperature dependence of the AC conductivity and relaxation times in humid electrical pressboard used in the insulation of power transformers, impregnated with the innovative NYTRO® BIO 300X bio-oil produced from plant raw materials. Tests were carried out for a composite of cellulose–bio-oil–water nanodroplets with a moisture content of 0.6% by weight to 5% by weight in the frequency range from 10−4 Hz to 5·103 Hz. The measurement temperatures ranged from 20 °C to 70 °C. The current conductivity in percolation channels in cellulose–bio insulating oil–water nanodroplets nanocomposites was analyzed. In such nanocomposites, DC conduction takes place via electron tunneling between the potential wells formed by the water nanodroplets. It was found that the value of the percolation channel resistance is lowest in the case of a regular arrangement of the nanodroplets. As disorder increases, characterized by an increase in the standard deviation value, the percolation channel resistance increases. It was found that the experimental values of the activation energy of the conductivity and the relaxation time of the composite of cellulose–bio-oil–water nanodroplets are the same within the limits of uncertainty and do not depend on the moisture content. The value of the generalized activation energy is ΔE ≈ (1.026 ± 0.0160) eV and is constant over the frequency and temperature ranges investigated. This study shows that in the lowest frequency region, the conductivity value does not depend on frequency. As the frequency increases further, the relaxation time decreases; so, the effect of moisture on the conductivity value decreases. The dependence of the DC conductivity on the moisture content was determined. For low moisture contents, the DC conductivity is practically constant. With a further increase in water content, there is a sharp increase in DC conductivity. Such curves are characteristic of the dependence of the DC conductivity of composites and nanocomposites on the content of the conducting phase. A percolation threshold value of xc ≈ (1.4 ± 0.3)% by weight was determined from the intersection of flat and steeply sloping sections. The frequency dependence of the values of the relative relaxation times was determined for composites with moisture contents from 0.6% by weight to 5% by weight for a measurement temperature of 60 °C. The highest relative values of the relaxation time τref occur for direct current and for the lowest frequencies close to 10−4 Hz. As the frequency increases further, the relaxation time decreases. The derivatives d(logτref)/d(logf) were calculated, from the analysis of which it was determined that there are three stages of relaxation time decrease in the nanocomposites studied. The first occurs in the frequency region from 10−4 Hz to about 3·10−1 Hz, and the second from about 3·10−1 Hz to about 1.5·101 Hz. The beginning of the third stage is at a frequency of about 1.5·101 Hz. The end of this stage is above the upper range of the Frequency Domain Spectroscopy (FDS) meter, which is 5·103 Hz. It has been established that the nanodroplets are in the cellulose and not in the bio-oil. The occurrence of three stages on the frequency dependence of the relaxation time can be explained when the fibrous structure of the cellulose is taken into account. Nanodroplets, found in micelles, microfibrils and in the fibers of which cellulose is composed, can have varying distances between nanodroplets, determined by the dimensions of these cellulose components.


  • Open Access

    Research on the Influence of Moisture in the Solid Insulation Impregnated with an Innovative Bio-Oil on AC Conductivity Used in the Power Transformers

    by Pawel Zukowski, Konrad Kierczynski, Przemyslaw Rogalski, Pawel Okal, Marek Zenker, Rafal Pajak, Marek Szrot, Pawel Molenda, Tomasz N. Koltunowicz

    The study determines the frequency–temperature dependence of the conductivity of a moist solid insulation component of power transformers, impregnated with the innovative bio-oil NYTRO® BIO 300X, manufactured from plant-based raw materials. The research was conducted for six moisture levels ranging from 0.6% to 5% by weight, within a frequency range from 10−4 Hz to 5 · 103 Hz and measurement temperatures from 20 °C to 70 °C, with a 10 °C step. The conduction model for both DC and AC, based on the quantum mechanical phenomenon of electron tunneling between water nanodroplets, was used to analyze the obtained results. It was determined that the frequency dependence of the conductivity of pressboard-bio-oil-moisture composites is influenced by two factors as follows: the activation energy of conductivity and the activation energy of relaxation time. For each moisture content, 16 values of the activation energy of the relaxation time and 16 values of the activation energy of conductivity were determined. It was found that the values of activation energy of conductivity and relaxation time are equal and independent of moisture content, frequency, and temperature. Based on 192 residual activation energy values, the mean generalized activation energy value for the relaxation time and conductivity was calculated with high precision, resulting in ΔE ≈ (1.02627 ± 0.01606) eV. The uncertainty of its determination was only ±1.6%. This indicates that electron tunneling from the first nanodroplet to the second, causing AC conductivity, and their return from the second nanodroplet to the first, determining the relaxation time, occur between the same energy states belonging to the water nanodroplets located in the pressboard impregnated with bio-oil. For each moisture content, the curves obtained for different measurement temperatures were recalculated to a reference temperature of 20 °C using the generalized activation energy. It was found that the shifted curves obtained for different temperatures perfectly overlap. Increased moisture content shifts the recalculated curves toward higher conductivity values. It was established that for all moisture contents in the lowest frequency range, conductivity is constant (DC conductivity). A further increase in frequency causes a rapid rise in conductivity. The increasing period can be divided into two stages. The first stage occurs up to about 100 Hz–101 Hz, depending on the moisture content. In the second stage, the rate of conductivity increase is higher, and its value depends on moisture content. The lower the moisture content, the faster the conductivity increases. Recalculation using the generalized activation energy eliminated the effect of temperature on the curves. It was found that the shapes of the recalculated curves and their position relative to the coordinates depend only on the moisture content in the composite. The equality of the activation energy of the relaxation time and conductivity established in the study, as well as their independence from frequency and moisture content in the pressboard impregnated with NYTRO® BIO 300X bio-oil, allows for recalculating the curves of electrical parameters determined at any operating temperatures of the transformer to a reference temperature, for example, 20 °C. Comparing the curve obtained for the transformer, recalculated to the reference temperature, with reference curves determined by us in the laboratory for different moisture contents, will allow for the precise determination of the moisture content of the solid insulation component impregnated with NYTRO® BIO 300X bio-oil. This will contribute to the early detection of approaching critical moisture content, threatening catastrophic transformer failure.


  • Open Access

    Research on the Influence of Matrix Shape on Percolation Threshold Values for Current Flow Conducted Using the Monte Carlo Simulation Method

    by Vitalii Bondariev, Pawel Okal, Przemyslaw Rogalski, Alexander Pogrebnjak, Pawel Zukowski

    In this study, in order to determine the effect of matrices’ shape on the percolation threshold values, computer simulations were performed using the Monte Carlo method for a 200 × 200 square-shaped matrix and rectangular matrices containing the same number of nodes as the square matrix. Based on the simulations, the average values of the percolation thresholds and standard deviations for the current flow along and across the matrices were determined. It was determined that for a square-shaped matrix, the average values of the percolation thresholds in both directions of the current flow were the same. Extending the rectangular matrix while reducing its height causes the average value of the percolation threshold in the direction of the current flow along the matrix to increase from 0.592740 to 0.759847, while in the transverse direction, it decreases from 0.592664 to 0.403614. The values of the classical asymmetry coefficients of the probability distributions of the percolation thresholds for both directions of the current flow were determined. Histograms of the probability distributions of the percolation threshold values for a square-shaped matrix and rectangular matrices were made and compared with the normal distributions. It was found that the occurrence of two percolation thresholds in rectangular layers should be considered when analyzing the electrical conductivity measurements of nanocomposite thin films.


  • Open Access

    Research on the Influence of Matrix Shape on Percolation Threshold Values for Current Flow Conducted Using the Monte Carlo Simulation Method

    by Vitalii Bondariev, Pawel Okal, Przemyslaw Rogalski, Alexander Pogrebnjak, Pawel Zukowski

    In this study, in order to determine the effect of matrices shape on percolation threshold values, computer simulations were performed using the Monte Carlo method for a 200x200 square-shaped matrix and rectangular matrices containing the same number of nodes as the square matrix. Based on the simulations, the average values of percolation thresholds and standard deviations for current flow along and across the matrices were determined. It was determined that for a square-shaped matrix, the average values of percolation thresholds in both directions of current flow were the same. Extending the rectangular matrix while reducing its height causes the average value of the percolation threshold in the direction of current flow along the matrix to increase from 0.592740 to 0.759847, while in the transverse direction it decreases from 0.592664 to 0.403614. The values of the classical asymmetry coefficients of the probability distributions of percolation thresholds for both directions of current flow were determined. Histograms of the probability distributions of percolation threshold values for square-shaped matrix and rectangular matrices were made and compared with normal distributions. It was found that the occurrence of two percolation thresholds in rectangular layers should be considered when analyzing electrical conductivity measurements of nanocomposite thin films.


  • Open Access

    Monte Carlo Simulation of Percolation Phenomena for Direct Current in Large Square Matrices

    by Pawel Zukowski, Pawel Okal, Konrad Kierczynski, Przemyslaw Rogalski, Vitalii Bondariev, Alexander D. Pogrebnjak

    In this study, an in-depth analysis of the percolation phenomenon for square matrices with dimensions from L = 50 to 600 for a sample number of 5 × 104 was performed using Monte Carlo computer simulations. The percolation threshold value was defined as the number of conductive nodes remaining in the matrix before drawing the node interrupting the last percolation channel, in connection with the overall count of nodes within the matrix. The distributions of percolation threshold values were found to be normal distributions. The dependencies of the expected value (mean) of the percolation threshold and the standard deviation of the dimensions of the matrix were determined. It was established that the standard deviation decreased with the increase in matrix dimensions, ranging from 0.0262253 for a matrix with L = 50 to 0.0044160 for L = 600, which is almost six-fold lower. The mean value of the percolation threshold was practically constant and amounted to approximately 0.5927. The analysis involved not only the spatial distributions of nodes interrupting the percolation channels but also the overall patterns of node interruption in the matrix. The distributions revealed an edge phenomenon within the matrices, characterized by the maximum concentration of nodes interrupting the final percolation channel occurring at the center of the matrix. As they approached the edge of the matrix, their concentration decreased. It was established that increasing the dimensions of the matrix slowed down the rate of decrease in the number of nodes towards the edge. In doing so, the area in which values close to the maximum occurred was expanded. Based on the approximation of the experimental results, formulas were determined describing the spatial distributions of the nodes interrupting the last percolation channel and the values of the standard deviation from the matrix dimensions. The relationships obtained showed that with increasing matrix dimensions, the edge phenomenon should gradually disappear, and the percolation threshold standard deviation values caused by it will tend towards zero.


  • Open Access

    Research on Changes in the Phase Shift Angle and Admittance of the Cellulose–Bio-Oil Composite under the Influence of Increasing Moisture during the Long-Term Operation of Power Transformers

    by Pawel Zukowski, Konrad Kierczynski, Paweł Okal, Przemyslaw Rogalski, Marek Zenker, Rafal Pajak, Pawel Molenda, Marek Szrot, Tomasz N. Koltunowicz

    In this study, the temperature–frequency dependencies of the pressboard–bio-oil–water nanoparticle composite’s fundamental parameters—phase shift angle and admittance—were examined using the Frequency Domain Spectroscopy method. Measurements were conducted in a frequency range of 10−4 Hz to 5 × 103 Hz at temperatures ranging from 293.15 K to 343.15 K, with a step of 10 K. The temperature stabilization accuracy was less than ±0.05 K. A total of 15 Arrhenius plots were determined for various phase shift angle values, from which 15 values and the average activation energy of relaxation time were determined. Similarly, the values of the activation energy of admittance relaxation time and the activation energy of admittance were determined. It was established that all three average values are identical within the bounds of uncertainty. Based on 45 values, a generalized activation energy was determined, with a value of ΔW ≈ (1.032 ± 0.0196) eV. Using the generalized activation energy value, the phase shift angle curves determined for all temperatures were recalculated to a temperature of 293.15 K. It was found that after conversion, all curves perfectly overlap. A similar operation was carried out for the frequency dependencies of admittance. In this case, too, the recalculated dependencies perfectly match. This means that the shape of the frequency dependencies of the phase shift angle and admittance depends solely on the moisture content in the pressboard–bio-oil–water nanodrop composite. The position of the curves in doubly logarithmic coordinates depends only on temperature and is determined by the generalized activation energy Using the generalized activation energy determined in this study will allow for the development of accurate methods for estimating moisture content in cellulose insulation of power transformers containing bio-oil. This will contribute to the detection of critical moisture content, which is about 5% by weight, and to the elimination of the risk, associated with such a high moisture content, of catastrophic failure of power transformers.


  • Open Access

    Analysis of Uneven Distribution of Nodes Creating a Percolation Channel in Matrices with Translational Symmetry for Direct Current

    by Pawel Zukowski, Pawel Okal, Konrad Kierczynski, Przemyslaw Rogalski, Vitalii Bondariev

    In this study, the phenomenon of node percolation was tested using the Monte Carlo computer simulation method for square matrices with dimensions L = 55, 101 and 151. The number of samples for each matrix was 5 × 106. The spatial distributions of the coordinates of the nodes creating the percolation channel were determined, and maps of the density distribution of these nodes were created. It has been established that in matrices with finite dimensions, an edge phenomenon occurs, consisting of a decrease in the concentration of nodes creating a percolation channel as one approaches the edge of the matrix. As the matrix dimensions increase, the intensity of this phenomenon decreases. This expands the area in which values close to the maximum occur. The length distributions of the left and right clusters of non-conducting nodes were determined for the situation when the next randomly selected node connects them and thus reaches the percolation threshold. It was found that clusters whose dimensions are close to half of the matrix dimensions are most likely to occur. The research shows that both the values of the standard deviation of the percolation threshold and the intensity of the edge phenomenon are clearly related to the dimensions of the matrices and decrease as they increase.