Vitaliy Tsirikhov
Research Subjects
Vitaliy Tsirikhov has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Mikhailovich Chernyavskii
National Medical Research Center named after Academician E.N. Meshalkin; Novosibirsk State Medical University
2 shared publications - Maksim Olegovych Zhulkov
Федеральное государственное бюджетное учреждение «Национальный медицинский исследовательский центр имени академика Е.Н. Мешалкина» Министерства здравоохранения Российской Федерации
2 shared publications - Sergey A. Al`sOv
Meshalkin National Medical Research Center
2 shared publications - Alexander Golovin
Joint-stock company "IMPULSE-project" Research and production company
1 shared publication - Alexander Sergeevich Grenaderov
The Institute of High Current Electronics SB RAS, 2/3, Akademichesky Ave., 634055 Tomsk, Russia
1 shared publication - Azat Kerimbekovich Sabetov
Федеральное государственное бюджетное учреждение «Национальный медицинский исследовательский центр имени академика Е.Н. Мешалкина» Министерства здравоохранения Российской Федерации, Новосибирск
1 shared publication
Latest Publications
- Open Access
- 28 September 2020
- Published by VSMU N.N. Burdenko in Journal of Experimental and Clinical Surgery
- Vol. 13 (3) , 256-261
Test Procedure for a New Type of a Ventricular Assist Device Based on a Viscous Friction Pump
Introduction. Currently, the possibility of effective correction of multiple organ failure and increasing the life expectancy of patients with critical heart failure using the ventricular assist devices (VAD) is absolutely evidenced. The development of alternative analogues of such devices produced within the country has been an urgent problem for many decades. The design of this machine requires the development of a protocol for carrying out complex biomedical studies on the biocompatibility and safety of the new device.The aim of the study was to develop a protocol for testing and conducting comprehensive biomedical biocompatibility studies of a new ventricular assist device in an acute animal experiment.Materials and methods. The study to develop a technique for implanting a left-ventricular assist device (LVAD) in an acute experiment included female mini-pigs, weighed 40-60 kg. In a series of acute experiments, 5 implantations of a disk pump as a LVAD were performed with a maximum observation period equal 6 hours.Results. In the series of acute experiments, an implantation technique was developed and the fundamental possibility of a viscous friction pump application as a ventricular assist device was evidenced. In all experiments (n = 5), the average level of free hemoglobin did not exceed 2.6 mg%, which supports safety of performance of the viscous friction pump regarding blood erythrocytes. None of the experiments recorded episodes of pump shut-off or breakdown.Conclusions. The series of acute experiments on mini-pigs helped reveal a number of anatomical and physiological features of this animal species that significantly complicated implementation of persistent observation. However, the developed experimental LVAD test methodology can be recommended for use in further chronic experiments on large laboratory animals (calves).
- 28 September 2020
- Published by VSMU N.N. Burdenko in Journal of Experimental and Clinical Surgery
- Vol. 13 (3) , 256-261
Open AccessTest Procedure for a New Type of a Ventricular Assist Device Based on a Viscous Friction Pump
Introduction. Currently, the possibility of effective correction of multiple organ failure and increasing the life expectancy of patients with critical heart failure using the ventricular assist devices (VAD) is absolutely evidenced. The development of alternative analogues of such devices produced within the country has been an urgent problem for many decades. The design of this machine requires the development of a protocol for carrying out complex biomedical studies on the biocompatibility and safety of the new device.The aim of the study was to develop a protocol for testing and conducting comprehensive biomedical biocompatibility studies of a new ventricular assist device in an acute animal experiment.Materials and methods. The study to develop a technique for implanting a left-ventricular assist device (LVAD) in an acute experiment included female mini-pigs, weighed 40-60 kg. In a series of acute experiments, 5 implantations of a disk pump as a LVAD were performed with a maximum observation period equal 6 hours.Results. In the series of acute experiments, an implantation technique was developed and the fundamental possibility of a viscous friction pump application as a ventricular assist device was evidenced. In all experiments (n = 5), the average level of free hemoglobin did not exceed 2.6 mg%, which supports safety of performance of the viscous friction pump regarding blood erythrocytes. None of the experiments recorded episodes of pump shut-off or breakdown.Conclusions. The series of acute experiments on mini-pigs helped reveal a number of anatomical and physiological features of this animal species that significantly complicated implementation of persistent observation. However, the developed experimental LVAD test methodology can be recommended for use in further chronic experiments on large laboratory animals (calves).
- Open Access
- 3 July 2020
- Published by Meshalkin National Medical Research Center in Patologiya krovoobrashcheniya i kardiokhirurgiya
- Vol. 24 (2) , 124-128
Coronary-artery bypass surgery using an operating microscope
This article presents our experience of using an operating microscope for coronary-artery bypass surgery. The technique, which was developed by the surgeons of Meshalkin National Medical Research Center, involves the use of an operating microscope for performing anastomosis and presents with major difficulties and disadvantages. This paper aims to simplify the procedure of performing anastomosis during coronary-artery bypass surgery using an operating microscope.Received 28 February 2020. Revised 24 March 2020. Accepted 25 March 2020.Funding: The study did not have sponsorship.Conflict of interest: Authors declare no conflict of interest.
- 3 July 2020
- Published by Meshalkin National Medical Research Center in Patologiya krovoobrashcheniya i kardiokhirurgiya
- Vol. 24 (2) , 124-128
Open AccessCoronary-artery bypass surgery using an operating microscope
This article presents our experience of using an operating microscope for coronary-artery bypass surgery. The technique, which was developed by the surgeons of Meshalkin National Medical Research Center, involves the use of an operating microscope for performing anastomosis and presents with major difficulties and disadvantages. This paper aims to simplify the procedure of performing anastomosis during coronary-artery bypass surgery using an operating microscope.Received 28 February 2020. Revised 24 March 2020. Accepted 25 March 2020.Funding: The study did not have sponsorship.Conflict of interest: Authors declare no conflict of interest.