OFOleg L. Fabrikantov

Oleg L. Fabrikantov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Oleg L. Fabrikantov has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Impact of e-Sports on Visual Function: A Systematic Review

    by S. V. Shutova, O. L. Fabrikantov, E. Yu. Fedorova, S. O. Kirillova

    E-Sports, recognized by the International Olympic Committee in 2017, is a rapidly growing discipline that requires high levels of visual endurance. However, despite the growing popularity of e-sports, scientific researches on its impact on the visual system remains limited. The aim of this systematic review was to analyze the existing data on the impact of e-sports on visual functions, identify key risk factors, and determine the gaps in current knowledge.The study methodology followed the PRISMA principles. The search for publications was performed in Elibrary, PubMed/MED-LINE, Elsevier, and Springer Link databases using key terms related to esports and health. Of the 1069 articles initially identified, after excluding duplicates and manually screening according to the inclusion and exclusion criteria, 19 relevant studies published between 2005 and 2022 were included in the analysis. The studies were conducted by authors from 8 countries with a total sample size of 3191 people (2805 e-sports athletes and 386 people of the control group). The analysis showed that the most studied aspects of the visual system of e-sports athletes are oculomotor activity and visual-motor reactions, while basic parameters (visual acuity, contrast sensitivity, accommodation) remain virtually unexplored. Risks of visual fatigue, decreased blink rate, and dry eye syndrome have been identified, but the long-term effects of video game addiction and prevention methods remain unstudied. Some positive effects of gaming on the speed and accuracy of complex visual-motor reactions and reactions to a moving object, the speed of detecting objects in simple and complex visual search tasks have been noted. The analysis revealed significant gaps in research, including the lack of long-term observations, standardized protocols for assessing visual system strain, and a comparative analysis of e-sports athletes with other groups exposed to screen loads. The results highlight the need to develop standards for ophthalmological support of e-sports athletes and conduct further research aimed at the early diagnosis and prevention of visual impairment.

  • Open Access

    Тенденции и прогнозирование младенческой и перинатальной смертности в Республиках Тыва, Хакасия и в Монголии

    by Николай Михайлович Агарков, Олег Львович Фабрикантов, Сергей Геннадьевич Емельянов, Антон Андреевич Титов, Мария Витальевна Алымова, Анастасия Алексеевна Шорохова

    В статье представлены результаты анализа динамики младенческой и перинатальной смертности, а также прогнозируемые уровни этих специальных демографических показателей в двух российских республиках Тыва, Хакасия и соседнем с ними государстве — Монголии. Исследование базируется на данных официальной статистики названных территорий за 2019–2022 гг. Для оценки динамики использованы интенсивные показатели, количественные показатели динамики — абсолютный прирост (убыль), темп прироста (убыли), темп роста (убыли), рассчитанные общепринятыми методами. Представлен сравнительный анализ динамики показателей младенческой и перинатальной смертности в двух Республиках Российской Федерации и соседнем государстве Монголия. Установлено, что средний уровень младенческой смертности статически значимо выше в Монголии, чем в Республике Хакасия и Республике Тыва. Рассчитанные показатели абсолютного прироста (убыли) и темпа прироста (убыли) свидетельствуют о снижении младенческой смертности в Республике Тыва за 2019–2022 гг. и об увеличении в Республике Хакасия при незначительных изменениях в Монголии. Уровень перинатальной смертности в Республиках Тыва и Хакасия не имел значимых различий и в обеих республиках достоверно повысился по величине абсолютного прироста, по величине темпа прироста, то есть более существенно в Республике Хакасия. В Монголии перинатальная смертность была достоверно выше. В ближайшие годы прогнозируется увеличение перинатальной смертности в Республиках Тыва и Хакасия, увеличение младенческой смертности в Республике Хакасия и снижение её в Республике Тыва, а в Монголии данные показатели останутся практически без изменений.

  • Diabetic macular edema: analysis of corticosteroid treatment results

    by Tambov Branch Academician S.N. Fyodorov Fsbi Irtc “Eye Microsurgery”, Nataljya V. Yablokova, Oleg L. Fabrikantov, Maxim M. Yablokov, Irina V. Makedonskaya

    Purpose: to evaluate the effectiveness and safety of treating diabetic macular edema with the intravitreal dexamethasone implant Ozurdex® (0.7 mg) in real clinical practice. Material and methods. In the Eye Microsurgery Institution, Tambov branch 70 patients (70 eyes) with diabetic macular edema were examined. All patients suffered from diabetes mellitus type 2. The dexamethasone-containing biodegradable implant Ozurdex® 0.7 mg was injected into the vitreous body according to a standard method in a hospital setting, followed by outpatient follow-up in 1, 3 and 6 months with monitoring of intraocular pressure, optical coherence tomography and best-corrected visual acuity monitoring. Results and discussion. After intravitreal administration of Ozurdex® for periods of 1 to 6 months, a statistically significant decrease in the central retinal thickness and an improvement in best-corrected visual acuity were noted in most patients throughout the entire follow-up. The peak of effectiveness was detected at the follow-up of 3 months and remained statistically significant for up to 6 months with a slight decrease in the effect due to a gradual decrease in the concentration of dexamethasone in the vitreous cavity. We noted a direct correlation between a decrease in retinal thickness according to optical coherence tomography data and an increase in best-corrected visual acuity. Conclusion. The use of intravitreal dexamethasone implant in diabetic macular edema leads to a gradual decrease in central retinal thickness and an increase in best-corrected visual acuity with various initial data, both as a first-line and second-line treatment, maintaining its effectiveness for 6 months.

  • Open Access

    Features of the inflammatory process in patients with social isolation and age-related macular degeneration

    by Academician S.N. Fyodorov Eye Microsurgery State Institution, Oleg L. Fabrikantov, Natalia V. Popova, Yuri Y. Blinkov, Kursk State Medical University, Anastasia A. Shorokhova, Southwest State University, Alexandra E. Voronina

    Актуальность: Приоритетной проблемой современной геронтологии и гериатрии в настоящее время называется социальная ...

  • Optimization of phacoemulsification technique for Morgagnian cataract

    by E.S. Pirogova, O.L. Fabrikantov, S.I. Nikolashin

    Purpose. This study was conducted to develop a new optimized phacoemulsification technique for Morgagnian cataract taking into account the anatomical and topographic parameters of the lens nucleus. Material and methods. A working classification of Morgagnian cataract was developed based on the size of the nucleus: if the edge of the nucleus is visualized at the upper edge of the pupil or between the upper edge and the middle of the pupil, it was classified as an initial stage of Morgagnian cataract with a large nucleus; if the upper edge of the nucleus is visualized in the middle of the pupil and below, it was classified as an advanced stage of Morgagnian cataract with a small nucleus. The first group included six patients who underwent surgery using the scaffold technique with removal of the whole small nucleus into the anterior chamber. The second group included 11 patients who underwent surgery using the scaffold technique with removal of the last fragment of the nucleus into the anterior chamber. Results. The use of the scaffold technique with removal of the nucleus into the anterior chamber helped reduce the number of intraoperative complications to 16.7% in the first group, compared to 27.3% in the second group, and the percentage of endothelial cell loss to 10.1% in the first group, compared to 10.7% in the second group. Conclusions. The anatomical and topographic features of the lens and the anterior segment of the eye in Morgagnian cataract with a small nucleus allow for preliminary implantation of an intraocular lens into the capsular bag to protect the posterior capsule during phacoemulsification of the nucleus with minimal mechanical, hydrodynamic and acoustic damage to the surrounding structures of the eye.


  • Open Access

    Machine-learning technology for predicting intraocular lens power: Diagnostic data generalization

    by Alexander А. Arzamastsev, Oleg L. Fabrikantov, Natalia А. Zenkova, Sergey V. Belikov, Александр Анатольевич Арзамасцев

    BACKGROUND: The implantation of recent intraocular lens (IOLs) allows ophthalmologists to effectively solve the surgical rehabilitation problems of patients with cataracts. The degree of improvement in the patient’s visual function is directly dependent on the accuracy of the preoperative calculation of the optical IOL power. The most famous formulas used to calculate this indicator include SRK II, SRK/T, Hoffer-Q, Holladay II, Haigis, and Barrett. All these work well for an “average patient”; however, they are not adequate at the boundaries of input variable ranges. AIM: To examine the possibility of using mathematical models obtained by deep learning of artificial neural network (ANN) models to generalize data and predict the optical power of modern IOLs. MATERIALS AND METHODS: ANN models were trained on large-scale samples, including depersonalized data for patients in the ophthalmology clinic. Data provided in 2021 by ophthalmologist K.K. Syrykh reflect the results of both preoperative and postoperative observations of patients. The source file used to build the ANN model included 455 records (26 columns of input factors and one column for the output factor) for calculating IOL (diopters). To conveniently build ANN models, a simulator program previously developed by the authors was used. RESULTS: The resulting models, in contrast to the traditionally used formulas, reflect the regional specificity of patients to a much greater extent. They also make it possible to retrain and optimize the structure based on newly received data, which allows us to consider the nonstationarity of objects. A distinctive feature of such ANN models in comparison with the well-known formulas SRK II, SRK/T, Hoffer-Q, Holladay II, Haigis, and Barrett, which are widely used in surgical cataract treatment, is their ability to consider a significant number of recorded input quantities, which reduces the mean relative error in calculating the optical IOL power from 10%–12% to 3.5%. CONCLUSION: This study reveals the fundamental possibility of generalizing a significant amount of empirical data on calculating the optical IOL power using training ANN models that have a significantly larger number of input variables than those obtained using traditional formulas and methods. The results obtained allow the construction of an intelligent expert system with a continuous flow of new data from a source and a step-by-step retraining of ANN models.


  • Open Access

    Classification of optical coherence tomography images using deep machine-learning methods

    by Alexander A. Arzamastsev, Oleg Lvovitch Fabrikantov, Elena Valerievna Kulagina, Nataly Alexandrovna Zenkova, Арзамасцев Александр Анатольевич

    BACKGROUND: Optical coherence tomography is a modern high-tech, insightful approach to detecting pathologies of the retina and preretinal layers of the vitreous body. However, the description and interpretation of study findings require advanced qualifications and special training of ophthalmologists and are highly time-consuming for both the doctor and the patient. Moreover, mathematical models based on artificial neural networks now allow for the automation of many image processing tasks. Therefore, addressing the issues of automated classification of optical coherence tomography images using deep learning artificial neural network models is crucial. AIM: To develop architectures of mathematical (computer) models based on deep learning of convolutional neural networks for the classification of retinal optical coherence tomography images; to compare the results of computational experiments conducted using Python tools in Google Colaboratory with single-model and multimodel approaches, and evaluate classification accuracy; and to determine the optimal architecture of models based on artificial neural networks, as well as the values of the hyperparameters used. MATERIALS AND METHODS: The original dataset included 2,000 anonymized optical coherence tomography images of real patients, obtained directly from the device with a resolution of 1,920×969×24 BPP. The number of image classes was 12. To create the training and validation datasets, a subject area of 1,100×550×24 BPP was “cut out”. Various approaches were studied: the possibility of using pretrained convolutional neural networks with transfer learning, techniques for resizing and augmenting images, and various combinations of the hyperparameters of models based on artificial neural networks. When compiling a model, the following parameters were used: Adam optimizer, categorical_crossentropy loss function, and accuracy. All technological operations involving images and models based on artificial neural networks were performed using Python language tools in Google Colaboratory. RESULTS: Single-model and multimodel approaches to the classification of retinal optical coherence tomography images were developed. Computational experiments on the automated classification of such images obtained from a DRI OCT Triton tomograph using various architectures of models based on artificial neural networks showed an accuracy of 98–100% during training and validation, and 85% during an additional test, which is a satisfactory result. The optimal architecture of the model based on an artificial neural network, a six-layer convolutional network, was selected, and the values of its hyperparameters were determined. CONCLUSION: Deep training of convolutional neural network models with various architectures, as well as their validation and testing, resulted in satisfactory classification accuracy of retinal optical coherence tomography images. These findings can be used in decision support systems in ophthalmology.


  • Open Access

    An improved technique for Morgagnian cataract phacoemulsification

    by E. S. Pirogova, O. L. Fabrikantov, S. I. Nikolashin

    Purpose: to develop new approaches to Morgagnian cataract surgery by optimizing the phacoemulsification technique and reducing the risk of surgical complications.Material and methods. 22 patients (22 eyes) with hypermature Morgagnian cataract were divided into 2 groups. The main group I included 11 patients who underwent surgery according to the PEC technology using iridocapsular retractors, an intracapsular ring and the scaffold technique with the last nucleus fragment relocated into the anterior chamber. The comparison group II included 11 patients with PEC and IOL implantation using iridocapsular retractors and an intracapsular ring with no scaffold technique involved. In 7 patients of group I, the lens nucleus was considered “large” and in 4 patients, “small”. In 8 patients of group II, the lens nucleus was considered “large” and in 3 patients, “small”.Results. After 6 months, BCVA in group I was 0.60, whilst in group II it was 0.70. IOP in group I averaged 12.9 mm Hg, while in group II it averaged 17.90 mm Hg. The endothelial cell density (CD) in group I decreased by 241 cells and amounted to 2012.0 cells/mm2 , the endothelial cell loss was 10.70%, while in group II CD loss was greater. It dropped by 377 cells (15.60%) and amounted to 2039 cells/mm2 .Conclusions. The severity of involutional changes in the ligamentous apparatus of the lens in Morgagnian cataract was found to depend on the nucleus size. A working classification of Morganian cataract by the nucleus size has been proposed. The use of scaffold technique with the relocation of the last fragment into the anterior chamber made it possible to reduce the share of surgical complications to 18.18%. During phacoemulsification of Morgagnian cataract with small nuclei, surgical complications took place in both group I and II, which necessitates further improvement of the existing surgical technique of this type of pathology.

  • Open Access

    Генерализация данных при расчете интраокулярных линз с использованием ИНС-моделей

    by Александр Анатольевич Арзамасцев, Олег Львович Фабрикантов, Наталья Александровна Зенкова, Сергей Вячеславович Беликов

    Исследуется возможность использования математических моделей, полученных в результате глубокого обучения искусственных нейронных сетей (ИНС-моделей) для прогнозирования оптической силы современных интраокулярных линз (ИОЛ), широко используемых при хирургическом лечении миопии в офтальмологии. Отличительной особенностью таких ИНС-моделей по сравнению с известными формулами SRK II, SRK/T, Hoffer-Q, Holladay II, Haigis, Barrett является возможность учета значительного числа регистрируемых входных величин, что позволило снизить среднюю относительную погрешность расчетов оптической силы ИОЛ с 10–12 % до 3,5 %. ИНС-модели обучали на значительных по объемам выборках, включающих обезличенные данные для 455 пациентов. Полученные ИНС-модели, в отличие от традиционно используемых формул, в значительно большей степени отражают региональную специфику пациентов, делают возможным переучивание и оптимизацию структуры модели на основе вновь поступающих данных, что делает возможным учитывать нестационарность объекта. Использование данного приема позволяет построить интеллектуальную экспертную систему с непрерывным поступлением новых данных из источника и поэтапным переучиванием ИНС-модели. Основные проблемы, возникающие при конструировании такой экспертной системы, обсуждаются в статье. Для удобного построения ИНС-моделей и их машинного обучения использовали программу-симулятор, ранее разработанную авторами данной статьи, а также средства языка Python в Google Colaboratory. При обучении моделей на основе эмпирических данных были выбраны следующие методы оптимизации: метод стохастического градиента, простой градиентный метод и безградиентные методы покоординатного спуска Гаусса — Зейделя и Монте — Карло, которые использовали в интерактивном режиме.

  • Open Access

    Combined Treatment of Post-Thrombotic Macular Edema with Navigation Laser Coagulation and Intravitreal Administration of Angiogenesis Inhibitors

    by I. A. Krylova, O. L. Fabrikantov

    At present about 16.4 million people in the world suffer from retinal venous occlusions (RVO). The pathophysiology of RVO includes changes in the vascular wall, blood flow, blood clotting. The key role in the pathogenesis of this group of diseases is played by ischemia and retinal hypoxia, leading to neovascularization. Macular edema (ME) is the most common complication of retinal vein occlusions. Optical coherence tomography-angiography (OCTA) is considered as an informative and highly sensitive method for diagnosing macular edema (ME) and ischemic zones in RVO. Intravitreal administration of glucocorticosteroids and/or angiogenesis inhibitors is the priority treatment method for macular edema in RVO. The combination of antiangiogenic therapy and laser treatment is promising. The navigation treatment technology is implemented under the conditions of the Navilas 577 system. The Navilas 577 laser navigation system is a laser coagulator with a tracking system and a fundus camera. The possibility of planning the operation, superimposing the results of OCTA on a fundus image makes the treatment faster, more accurate, and minimizes damage to healthy tissues.Purpose: to evaluate the results of target topographically oriented threshold laser coagulation in the treatment of post-thrombotic ME using theNavilas 577 laser navigation system following intravitreal administration of angiogenesis inhibitors.Materials and methods. There was performed a prospective study of the results of navigation laser treatment on the Navilas 577 device after intravitreal injections of angiogenesis inhibitors in 14 patients (14 eyes), aged 51 to 83 years, with macular edema up to 390 μm due to the branch central retinal vein occlusion. Laser treatment was performed within 2 weeks to 1 month following the last injection of angiogenesis inhibitors. The zones of ischemia in the macula were determined according to OCT-A data, imported into the Navilas 577 navigation system and superimposed on a color fundus image. Then the treatment was planned — the position of the future coagulates was marked.Results. In 3 months, there was a decrease in the height of edema from 366.5 (323;390) to 280 (270;300) μm, an increase in light sensitivity in the central retinal zone from 17 to 21.2 dB and an increase in visual acuity from 0.4 (0.3;0.5) to 0.5 (0.45;0.6).Conclusion. The combination of navigation retinal laser coagulation and angiogenesis inhibitors in the treatment of low post-thrombotic edema (less than 390 μm) gives good results; therefore, it can be justified and advisable in real clinical practice.