LFLaurent Fiorina

Laurent Fiorina

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Laurent Fiorina has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The Electrocardiogram as a Preventive Biomarker: From Conventional Risk Markers to Actionable Artificial Intelligence - A Narrative Review

    by Rodrigue Garcia, Aymeric Menet, Josselin Duchateau, Laurent Fiorina, Abderrazzaq Moufidi, Jérôme Taieb, Benoit Lequeux, Olivier Piot

    The electrocardiogram (ECG) is an established tool in cardiovascular prevention, identifying silent arrhythmias, hypertrophy, prior myocardial infarction, conduction disease, and inherited electrical disorders. However, conventional interpretation captures only a fraction of the information embedded in the cardiac electrical signal. Because the ECG is inexpensive, non-invasive, standardized, and already acquired at scale, it provides an attractive substrate for artificial intelligence (AI)-enabled screening and risk stratification. Deep-learning models can identify latent signatures of ventricular dysfunction, structural heart disease, atrial fibrillation, cardiomyopathy, heart failure, and mortality risk. Importantly, evidence is beginning to extend beyond retrospective validation: prospective implementation studies have increased disease detection, while randomized data suggest that AI-ECG–guided clinical alerts may improve outcomes in selected high-risk populations. Whether such benefits extend to preventive populations remains uncertain. This review examines the preventive role of conventional, ambulatory, and wearable ECGs and distinguishes AI applications for detection, prediction, prognostication, treatment selection, and longitudinal monitoring. We argue that performance metrics alone are insufficient. Preventive value requires a defined target population, calibrated and externally validated predictions, an appropriate confirmatory test, a feasible clinical workflow, and an intervention proven to improve outcomes. The most credible near-term applications are those that triage patients to established diagnostic pathways, such as echocardiography or prolonged rhythm monitoring. The central challenge is therefore to transform accurate AI-ECG predictions into actionable, affordable, scalable, safe, and equitable prevention.

  • Deep Learning Can Unmask Conduction Tissue Disease From an Ambulatory ECG

    by Laurent Fiorina, Tanner Carbonati, Baptiste Maille, Kumar Narayanan, Pauline Porquet, Christine Henry, Jagmeet P. Singh, Eloi Marijon, Jean-Claude Deharo

    BACKGROUND: Bradyarrhythmia is a common and potentially serious cause of syncope, often difficult to detect due to its intermittent nature. Traditional ECG monitoring methods either provide low diagnostic accuracy or delay diagnosis, increasing the risk of recurrence. We hypothesized that a deep learning–enabled, 24-hour, single-lead ECG could detect past episodes of bradyarrhythmia. METHODS: Using unselected 14-day single-lead ambulatory ECG recordings, we developed a deep learning model to identify patients with prior asystole from sinus arrest or complete heart block. The model was trained using the last 24 hours of each recording, free of bradyarrhythmias, to identify daytime sinus pause of ≥3 s, anytime sinus pause of ≥6 s, complete heart block, or a composite of these bradyarrhythmias from the previous 13 days. RESULTS: A total of 320 959 unselected 14-day ambulatory ECG recordings (mean age, 60.5±17.8 years; 60% female) were split into training (n=189 414), tuning (n=45 982), internal validation (n=43 390), and external validation (n=42 173) sets. External validation of prior daytime sinus pause ≥3 s, anytime sinus pause ≥6 s, complete heart block, and a composite end point demonstrated an area under the receiver operating characteristic curve of 0.89, 0.87, 0.93, and 0.89, respectively, with negative predictive values between 97.9 and 99.9%. In addition to this approach of uncovering past events, our model was also tested for its ability to predict bradyarrhythmias within the following 13 days using the first 24 hours of ECG data, achieving an AUC of 0.88 for the composite end point. CONCLUSIONS: A deep learning–enabled ambulatory ECG is capable of unmasking underlying conduction tissue system disease. This tool may help identify patients with significant intermittent bradyarrhythmia, potentially improving timely diagnosis and management.


  • Open Access

    Early Failure of Subcutaneous ICD in a Patient With a Variant of Rapidly Progressive ARVC

    by Alexandre Cinq-Mars, Fiorella Salerno, Christian Steinberg, Jérôme Garot, Suzanne Duhamel, Mina Ait Said, Jérôme Horvilleur, Jérôme Lacotte, Salem Younsi, Laurent Fiorina


  • Top Cited Papers
    Open Access

    Near-term prediction of sustained ventricular arrhythmias applying artificial intelligence to single-lead ambulatory electrocardiogram

    by Laurent Fiorina, Tanner Carbonati, Kumar Narayanan, Jia Li, Christine Henry, Jagmeet P Singh, Eloi Marijon

    Background and Aims: Accurate near-term prediction of life-threatening ventricular arrhythmias would enable pre-emptive actions to prevent sudden cardiac arrest/death. A deep learning–enabled single-lead ambulatory electrocardiogram (ECG) may identify an ECG profile of individuals at imminent risk of sustained ventricular tachycardia (VT). Methods: This retrospective study included 247 254, 14 day ambulatory ECG recordings from six countries. The first 24 h were used to identify patients likely to experience sustained VT occurrence (primary outcome) in the subsequent 13 days using a deep learning–based model. The development set consisted of 183 177 recordings. Performance was evaluated using internal (n = 43 580) and external (n = 20 497) validation data sets. Saliency mapping visualized features influencing the model’s risk predictions. Results: Among all recordings, 1104 (.5%) had sustained ventricular arrhythmias. In both the internal and external validation sets, the model achieved an area under the receiver operating characteristic curve of .957 [95% confidence interval (CI) .943–.971] and .948 (95% CI .926–.967). For a specificity fixed at 97.0%, the sensitivity reached 70.6% and 66.1% in the internal and external validation sets, respectively. The model accurately predicted future VT occurrence of recordings with rapid sustained VT (≥180 b.p.m.) in 80.7% and 81.1%, respectively, and 90.0% of VT that degenerated into ventricular fibrillation. Saliency maps suggested the role of premature ventricular complex burden and early depolarization time as predictors for VT. Conclusions: A novel deep learning model utilizing dynamic single-lead ambulatory ECGs accurately identifies patients at near-term risk of ventricular arrhythmias. It also uncovers an early depolarization pattern as a potential determinant of ventricular arrhythmias events.


  • Open Access

    Artificial intelligence–based electrocardiogram analysis improves atrial arrhythmia detection from a smartwatch electrocardiogram

    by Laurent Fiorina, Pascale Chemaly, Joffrey Cellier, Mina Ait Said, Charlène Coquard, Salem Younsi, Fiorella Salerno, Jérôme Horvilleur, Jérôme Lacotte, Vladimir Manenti, et al.

    Aims: Smartwatch electrocardiograms (SW ECGs) have been identified as a non-invasive solution to assess abnormal heart rhythm, especially atrial arrhythmias (AAs) that are related to stroke risk. However, the performance of these tools is limited and could be improved with the use of deep neural network (DNN) algorithms, particularly for specific populations encountered in clinical cardiology practice. Methods and results: A total of 400 patients from the electrophysiology department of one tertiary care hospital were included in two similar clinical trials (respectively, 200 patients per study). Simultaneous ECGs were recorded with the watch and a 12-lead recording system during consultation or before and after an electrophysiology procedure if any. The SW ECGs were processed by using the DNN and with the Apple watch ECG software (Apple app). Corresponding 12-lead ECGs (12L ECGs) were adjudicated by an expert electrophysiologist. The performance of the DNN was assessed vs. the expert interpretation of the 12L ECG, and inconclusive rates were reported. Overall, the DNN and the Apple app presented, respectively, a sensitivity of 91% [95% confidence interval (CI) 85–95%] and 61% (95% CI 44–75%) with a specificity of 95% (95% CI 91–97%) and 97% (95% CI 93–99%) when compared with the physician 12L ECG interpretation. The DNN was able to provide a diagnosis on 99% of ECGs, while the Apple app was able to classify only 78% of strips (22% of inconclusive diagnosis). Conclusion: In this study, by including patients from a cardiology department, a DNN-based algorithm applied to an SW ECG provided an accurate diagnosis for AA detection on virtually all tracings, outperforming the SW algorithm.


  • Open Access

    Evaluation of an Ambulatory ECG Analysis Platform Using Deep Neural Networks in Routine Clinical Practice

    by Laurent Fiorina, Carole Maupain, Christophe Gardella, Vladimir Manenti, Fiorella Salerno, Pierre Socie, Jia Li, Christine Henry, Audrey Plesse, Kumar Narayanan, et al.

    Background: Holter analysis requires significant clinical resources to achieve a high‐quality diagnosis. This study sought to assess whether an artificial intelligence (AI)‐based Holter analysis platform using deep neural networks is noninferior to a conventional one used in clinical routine in detecting a major rhythm abnormality. Methods and Results: A total of 1000 Holter (24‐hour) recordings were collected from 3 tertiary hospitals. Recordings were independently analyzed by cardiologists for the AI‐based platform and by electrophysiologists as part of clinical practice for the conventional platform. For each Holter, diagnostic performance was evaluated and compared through the analysis of the presence or absence of 5 predefined cardiac abnormalities: pauses, ventricular tachycardia, atrial fibrillation/flutter/tachycardia, high‐grade atrioventricular block, and high burden of premature ventricular complex (>10%). Analysis duration was monitored. The deep neural network–based platform was noninferior to the conventional one in its ability to detect a major rhythm abnormality. There were no statistically significant differences between AI‐based and classical platforms regarding the sensitivity and specificity to detect the predefined abnormalities except for atrial fibrillation and ventricular tachycardia (atrial fibrillation, 0.98 versus 0.91 and 0.98 versus 1.00; pause, 0.95 versus 1.00 and 1.00 versus 1. 00; premature ventricular contractions, 0.96 versus 0.87 and 1.00 versus 1.00; ventricular tachycardia, 0.97 versus 0.68 and 0.99 versus 1.00; atrioventricular block, 0.93 versus 0.57 and 0.99 versus 1.00). The AI‐based analysis was >25% faster than the conventional one (4.4 versus 6.0 minutes; P <0.001). Conclusions: These preliminary findings suggest that an AI‐based strategy for the analysis of Holter recordings is faster and at least as accurate as a conventional analysis by electrophysiologists.


  • COVID-19 et troubles du rythme

    by L. Fiorina, S. Younsi, J. Horvilleur, V. Manenti, J. Lacotte, C. Raimondo, P. Chemaly, F. Salerno, M. Ait Said


  • Effectiveness and safety of flecainide in arrhythmogenic right ventricular cardiomyopathy

    by F. Bouvier, C. Maupain, N.C. Roche, L. Fiorina, D. Poindron, C. Moini, E. Gandjbakhch