Wee Chew
Wee Chew has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
Aaron Thong
2 shared publications- Aaron Thong
Singapore Institute of Food and Biotechnology Innovation (SIFBI), Agency for Science, Technology and Research (A*STAR), 31 Biopolis Way, Nanos, Singapore 138669, Singapore
2 shared publications Dennis Leung
2 shared publicationsFitriani Nur Eka
2 shared publications- Jorry Dharmawan
Food, Chemical and Biotechnology Cluster, Singapore Institute of Technology, 1 Punggol Coast Road, Singapore 828608, Singapore
2 shared publications Leng Wei Khoo
Singapore Institute of Food and Biotechnology Innovation, Agency for Science, Technology and Research (A*STAR), Singapore, 138669, Singapore
2 shared publications
Latest Publications
- 2 June 2024
- Published by Elsevier in Biochemical Engineering Journal
- Vol. 209
Biokinetics modelling of lycopene-producing E. coli fermentation using PAT methodology
- 2 June 2024
- Published by Elsevier in Biochemical Engineering Journal
- Vol. 209
Biokinetics modelling of lycopene-producing E. coli fermentation using PAT methodology
- Open Access
- 10 March 2024
- Published by Wiley
In-line Dielectric and Raman Monitoring of Intracellular Lycopene Production in E. coli Fermentation Scale-Up
The use of in-line analytics for monitoring and understanding biological processes has been promoted since 2004 through the Process Analytical Technology (PAT) initiative. Two such technologies are Raman and dielectric spectroscopies that are well established but deployed independently. For the very first time, simultaneous usage of in-line Raman and dielectric spectroscopic analytics for tracking progress of a lycopene overproducer E. coli 322 engineered strain was studied herein, alongside scale-up experimentation from shake flask to 0.5L and 10L bioreactor cultures. An intracellular lycopene extraction protocol was optimised for off-line quantification by Raman or UV-Vis spectroscopies, which aids the estimation of lycopene over-production in a high cell density E. coli fed-batch culture via in-line Raman. Correlating dielectric capacitance recordings and flow cytometry viable cell count measurements allows for real-time cell culture viability monitoring, which is more informative for bioprocess dynamic control in contrast to conventional in-/off-line biomass optical density (OD 600 ) or dry cell weight (g DCW ). This enabled fed-batch culture revitalisation prior to inducing intracellular lycopene production. The final biomass OD 600 was ca. 81.8 corresponding to in-line dielectric capacitance estimated culture viability 43.38 g VCC /L. Intracellular lycopene yield was estimated at 495.1 mg/g VCC via in-line Raman, which was 12.3 times increase compared to initial trial reported for E. coli 322. The successful implementation of dual in-line dielectric capacitance and Raman monitoring exemplifies the quality by design (QbD) approach espoused by PAT framework for expediting bioprocess understanding, development and scale-up of engineered microbial strains.
- 10 March 2024
- Published by Wiley
Open AccessIn-line Dielectric and Raman Monitoring of Intracellular Lycopene Production in E. coli Fermentation Scale-Up
The use of in-line analytics for monitoring and understanding biological processes has been promoted since 2004 through the Process Analytical Technology (PAT) initiative. Two such technologies are Raman and dielectric spectroscopies that are well established but deployed independently. For the very first time, simultaneous usage of in-line Raman and dielectric spectroscopic analytics for tracking progress of a lycopene overproducer E. coli 322 engineered strain was studied herein, alongside scale-up experimentation from shake flask to 0.5L and 10L bioreactor cultures. An intracellular lycopene extraction protocol was optimised for off-line quantification by Raman or UV-Vis spectroscopies, which aids the estimation of lycopene over-production in a high cell density E. coli fed-batch culture via in-line Raman. Correlating dielectric capacitance recordings and flow cytometry viable cell count measurements allows for real-time cell culture viability monitoring, which is more informative for bioprocess dynamic control in contrast to conventional in-/off-line biomass optical density (OD 600 ) or dry cell weight (g DCW ). This enabled fed-batch culture revitalisation prior to inducing intracellular lycopene production. The final biomass OD 600 was ca. 81.8 corresponding to in-line dielectric capacitance estimated culture viability 43.38 g VCC /L. Intracellular lycopene yield was estimated at 495.1 mg/g VCC via in-line Raman, which was 12.3 times increase compared to initial trial reported for E. coli 322. The successful implementation of dual in-line dielectric capacitance and Raman monitoring exemplifies the quality by design (QbD) approach espoused by PAT framework for expediting bioprocess understanding, development and scale-up of engineered microbial strains.
- Open Access
- 15 October 2022
- Published by Elsevier in Metabolic Engineering Communications
- Vol. 15, e00209
Metabolomics and modelling approaches for systems metabolic engineering
- 15 October 2022
- Published by Elsevier in Metabolic Engineering Communications
- Vol. 15, e00209
Open AccessMetabolomics and modelling approaches for systems metabolic engineering
- 30 December 2020
- Published by Royal Society of Chemistry (RSC) in Reaction Chemistry & Engineering
- Vol. 6 (3) , 538-547
Calibration methods to circumvent unknown component spectra for quantitative in situ Raman monitoring of co-polymerization reactions
PLS, MMSR, and BTEM-MLR were successfully applied to Raman monitoring of co-polymerization.
- 30 December 2020
- Published by Royal Society of Chemistry (RSC) in Reaction Chemistry & Engineering
- Vol. 6 (3) , 538-547
Calibration methods to circumvent unknown component spectra for quantitative in situ Raman monitoring of co-polymerization reactions
PLS, MMSR, and BTEM-MLR were successfully applied to Raman monitoring of co-polymerization.
- 28 September 2020
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 36 (1) , 159-166
Characterization of volatile compounds in Ylang‐Ylang essential oils from Comoros and Madagascar by gas chromatography and principal component analysis
Chemical composition of ylang‐ylang essential oil is affected by the geographical origins of flowers used for extraction. This study aimed to determine the compositional difference between the extra, first and third grades of ylang‐ylang essential oil from Comoro Islands and Madagascar. The oils were characterized by both gas chromatography‐mass spectrometry (GC‐MS) and gas chromatography‐flame ionization detector (GC‐FID) in conjunction with principal component analysis (PCA). A total of 124 volatile compounds were identified and quantified by GC‐MS and GC‐FID. Twenty‐two compounds that made up 85% to 90% of the oils were shortlisted to compare across grades and geographical origins. The PCA showed that the ylang‐ylang essential oils are clustered according to grade and origin based on their compositions. Analysis of variance was performed to determine the statistical significance of the differences between each compound across extra, first and third grades of ylang‐ylang essential oil from Madagascar and Comoros. The oils of Madagascar are dominating in geranyl acetate, cis‐α‐farnesene, benzyl benzoate, humulene and caryophyllene, while in those of Comoros, cinnamyl acetate, benzyl salicylate, trans‐farnesyl acetate and α‐farnesene are found to be higher. It is possible to verify the origin and grade of an unspecified source of ylang‐ylang essential oil from the biplot of the 22 compounds.
- 28 September 2020
- Published by Wiley in Flavour and Fragrance Journal
- Vol. 36 (1) , 159-166
Characterization of volatile compounds in Ylang‐Ylang essential oils from Comoros and Madagascar by gas chromatography and principal component analysis
Chemical composition of ylang‐ylang essential oil is affected by the geographical origins of flowers used for extraction. This study aimed to determine the compositional difference between the extra, first and third grades of ylang‐ylang essential oil from Comoro Islands and Madagascar. The oils were characterized by both gas chromatography‐mass spectrometry (GC‐MS) and gas chromatography‐flame ionization detector (GC‐FID) in conjunction with principal component analysis (PCA). A total of 124 volatile compounds were identified and quantified by GC‐MS and GC‐FID. Twenty‐two compounds that made up 85% to 90% of the oils were shortlisted to compare across grades and geographical origins. The PCA showed that the ylang‐ylang essential oils are clustered according to grade and origin based on their compositions. Analysis of variance was performed to determine the statistical significance of the differences between each compound across extra, first and third grades of ylang‐ylang essential oil from Madagascar and Comoros. The oils of Madagascar are dominating in geranyl acetate, cis‐α‐farnesene, benzyl benzoate, humulene and caryophyllene, while in those of Comoros, cinnamyl acetate, benzyl salicylate, trans‐farnesyl acetate and α‐farnesene are found to be higher. It is possible to verify the origin and grade of an unspecified source of ylang‐ylang essential oil from the biplot of the 22 compounds.
- 31 March 2011
- Published by American Chemical Society (ACS) in Organic Process Research & Development
- Vol. 15 (3) , 610-621
Reactor Kinetics Studies via Process Raman Spectroscopy, Multivariate Chemometrics, and Kinetics Modeling
- 31 March 2011
- Published by American Chemical Society (ACS) in Organic Process Research & Development
- Vol. 15 (3) , 610-621
Reactor Kinetics Studies via Process Raman Spectroscopy, Multivariate Chemometrics, and Kinetics Modeling
- 1 July 2007
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 61 (7) , 734-746
Spectral Renormalization for Multi-Component Fourier Transform Infrared Absorbance Data: Importance to Multivariate Calibration and Quantitative Exploratory Chemometrics Studies
Although infrared spectroscopy is a very common analytical tool in the chemical sciences, quantitative infrared spectroscopic studies of multi-component solutions (particularly on-line or in-line studies) have been hampered by the lack of a concise and robust numerical approach. Using an inert chemical species as internal standard, the usual absorbance ratio analysis is generalized into a mathematical form that converts typical absorbance measurement A into its renormalized absorbance Arenorm, with the latter directly relating to the absolute moles rather than the concentration of the constituents. The renormalized absorbance has a number of very important properties, including (1) insensitivity to path length changes due to variations in temperature or pressure of the Fourier transform infrared (FT-IR) cell and (2) insensitivity to solution volume changes arising from reaction, chemical transport, or thermodynamic conditions. The methodology is first applied to a simple model test system to demonstrate its utility for multivariate calibration, and then re-applied to a real problem: the calibration of the rhodium carbonyl hydride HRh(CO)4, a long-sought species in organometallic chemistry and homogeneous catalysis (Angewandte Chemie Int. Ed., vol. 41, 3786 (2002)). The utility of the developed methodology for multivariate calibration and exploratory chemometric studies is demonstrated. Emphasis is placed on providing a numerical recipe for the practicing analytical chemist.
- 1 July 2007
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 61 (7) , 734-746
Spectral Renormalization for Multi-Component Fourier Transform Infrared Absorbance Data: Importance to Multivariate Calibration and Quantitative Exploratory Chemometrics Studies
Although infrared spectroscopy is a very common analytical tool in the chemical sciences, quantitative infrared spectroscopic studies of multi-component solutions (particularly on-line or in-line studies) have been hampered by the lack of a concise and robust numerical approach. Using an inert chemical species as internal standard, the usual absorbance ratio analysis is generalized into a mathematical form that converts typical absorbance measurement A into its renormalized absorbance Arenorm, with the latter directly relating to the absolute moles rather than the concentration of the constituents. The renormalized absorbance has a number of very important properties, including (1) insensitivity to path length changes due to variations in temperature or pressure of the Fourier transform infrared (FT-IR) cell and (2) insensitivity to solution volume changes arising from reaction, chemical transport, or thermodynamic conditions. The methodology is first applied to a simple model test system to demonstrate its utility for multivariate calibration, and then re-applied to a real problem: the calibration of the rhodium carbonyl hydride HRh(CO)4, a long-sought species in organometallic chemistry and homogeneous catalysis (Angewandte Chemie Int. Ed., vol. 41, 3786 (2002)). The utility of the developed methodology for multivariate calibration and exploratory chemometric studies is demonstrated. Emphasis is placed on providing a numerical recipe for the practicing analytical chemist.