    Experimental identification of the corrective capabilities of the spring technique in addressing multiapical femoral deformities

    by Leonid N. Solomin, Evgeniy S. Golovenkin, Fanil K. Sabirov, Anna V. Veshnyakova

    Background. The technique of multiapical deformities correction with several orthopedic hexapods (one for each apex of deformity) is accepted as a standard one. However, usage of two or more hexapods on one segment is uncomfortable for the patient. Besides, software calculation for each of them is difficult and laborious for an orthopedic surgeon. Application of only one orthopedic hexapod with one software calculation is the advantage of the spring technique (ST) of multiapical deformities correction. However, its application is hindered by the fact that the corrective capabilities of this technique have not been studied yet. The aim of the study was to identify by the bench test the corrective capabilities of the spring technique and compare them with the capabilities of the standard one. Methods. The bench test was performed using plastic models of the femur. One-ring modules were used to fix each of the bone fragments. Foam rubber discs were used to imitate soft tissues. The mobile ring was moved relative to the base one in translation, angulation, distraction and rotation. The movement was stopped if one of the struts reached its minimum or maximum length, as well as if one of them touched a frame, transosseous elements or “soft tissues”. The Mann-Whitney U-test was used for statistical analysis. Results. When using all the six struts equipped with standard threaded rods, the corrective capabilities of the spring technique are 58-97% (on average 72%) lower than of the standard one. When replacing 2-6 (depending on the type of motion) threaded rods with longer ones, the capabilities of ST increases by 36-466% (on average 257%). This provides better result for ST in translation (in three directions), varus and recurvation angulation. Conclusions. Corrective capabilities of the spring technique in 5 out of 11 types of motions are better than the capabilities of the standard technic if struts of the orthopedic hexapod are equipped with threaded rods of greater length.


  • Open Access

    Lower limbs lengthening over the intramedullary nail versus lengthening by Ilizarov technique

    by E. A. Shchepkina, I. V. Lebedkov, L. N. Solomin, K. L. Korchagin, F. K. Sabirov, D. G. Parfeev

    Introduction. Lengthening over the nail (LON) combines the advantages of external and internal fixations.The objective was to compare the effectiveness of the application, to assess the structure and frequency of complications in patients treated with lengthening by Ilizarov technique and lengthening over the nail.Methods and materials. We analyzed 55 LON cases and 64 cases lengthening by Ilizarov technique. The duration of the external fixation period, complications and quality of the patient life were compared.Results. The external fixation period in LON group was 4 times less than in the Ilizarov technique group. There were 25 complications (45.5 %) in LON group and 54 complications (84.4 %) in the Ilizarov technique group. Femur lengthening was associated with a greater number of complications in both groups. Pin infections were 2.5 times less frequently in the femur LON group. Knee contractures were only in Ilizarov technique group (11.4 %). Ankle joint contracture was noted with the same frequency during tibial lengthening in both groups. Disorders of the consolidation were 2 times more often in the femur LON group and 5 times more often in the tibial lengthening with Ilizarov technique. Premature fusion was observed only in the LON group. There were 2 times less fractures of the half-pins and wires in the LON group.Conclusions. A reduction of external fixation period in LON group correlates with the 2-fold decrease of complications and an increase of the treatment comfort. LON is promising for wider clinical applications.


  • Open Access

    Bone transport over the nail vs Ilizarov method in the treatment of posttraumatic defects of the femur and tibia

    by E. A. Shchepkina, N. L. Solomin, K. L. Korchagin, F. K. Sabirov

    Relevance. From the point of view of using the advantages of both external fixation and internal osteosynthesis, the method “Bone transport over the nail” (BTON) deserves attention.Intention: To compare the effectiveness of the BTON and Ilizarov method in the treatment of patients with post-traumatic defects of the long bones of the lower extremities.Methodology. We analyzed 24 BTON cases and 47 cases of defects replacement via the Ilizarov method. The analysis included patients with segmental defects of the tibia, femur and knee joint bone defects complicated by chronic osteomyelitis.Results and Discussion. The external fixation period in BTON group was 3 times less than in the comparison group, as was the external fixation index. In case of monolocal defect replacement, the external fixation period and external fixation index in the BTON group was 4 times less than in the Ilizarov defect replacement group. With bifocal replacement of the defect, the external fixation period was 2.5 times less, and the external fixation index was 2 times less. BTON interventions were associated with complications in 31 cases (129.2 %) vs 82 cases for the Ilizarov method (174.5 %). The most pronounced decrease (3 times) was noted for cases of transosseous elements inflammation.Conclusion. The “Bone transport over the nail” technique reduces the external fixation period by an average of 3 times. This facilitates management of the outpatient phase and reduces the number of complications, especially the pin-tract infection. Cable technique combined with an orthopedic hexapod allows bifocal replacement of extended defects of the distal femur and knee joint applying the apparatus only to the lower leg. Risks of jamming the transported bone fragments by the intramedullary nail are thus excluded. To avoid breaking the traction cable, only designated devices should be used.


  • Open Access

    Comparative Analysis of Knee Joint Fusion with Long Locking Nail and Ilizarov Apparatus in Patients with Deep Infection after Arthroplasty

    by L. N. Solomin, E. A. Shchepkina, K. L. Korchagin, F. K. Sabirov

    Relevance. Deep infection after knee arthroplasty requires radical surgical treatment of the infection site, removal of endoprosthesis components, and an antimicrobial spacer placement. If revision knee arthroplasty is impossible, the «gold standard» for this kind of patients is knee joint arthrodesis. The purpose of the study was the comparative analysis of knee joint fusion by external and internal fixation. Materials and Methods. The analysis of 60 cases of knee arthrodesis was carried out. The patients were divided into two groups with 30 patients in each. In the first group, knee arthrodesis was performed with long locking nail, in the second group — with external ring fixation. We compared the groups by intraoperative and drainage blood loss, the inpatient treatment duration, the terms of fusion and complications registered. The patients quality of life was evaluated using the SF-36 questionnaire before surgery, for the periods of 3, 6, and 12 months after the surgery. Results. The comparison of two methods of knee arthrodesis showed that blood loss in the internal fixation compared with external one, was 2.03 times more, the duration of inpatient treatment was 1.4 times less, and the total number of complications was 4.4 times less. However, the complications that affected the treatment outcome in long nail group were 1.5 times more. The differences in the average time of ankylosis formation were not statistically significant (p0.05). The functional results of the treatment in 3 months after surgery in the group with internal fixation were much better. In 6 months after surgery the quality of life had no significant differences. In 12 months follow-up the indices in both groups were the same. Conclusion. The results of our study suggests us to think, knee joint arthrodesis by long fusion nail should be prefereble. If the nail insertion is technically impossible, and there is the high risk of deep infection recurrence, the external osteosynthesis should be used.


  • Open Access

    Complications in the Combined and Consecutive Use of External and Internal Fixation of the Femur with Reference to Use of the Extracortical Clamp Device

    by Leonid N. Solomin, Fanil K. Sabirov, Matthew Fletcher, Arvid B. Abolin, Dawson Creek Dawson Creek And District Hospital

    AimThe Extracortical Clamp Device (ECD) is a novel external fixation component which unlike conventional implants does notperforate long bone cortices. Therefore, it simplifies methods of combined and consecutive internal and external fixation, periprosthetic fracture osteosynthesis and deformity correction. This study compared the incidence of complications with the use ofthe ECD in combined external fixation of the femur.MethodsA prospective controlled study was designed with one group including 66 frames assembled using the ECD. These were comparedwith the second group of 29 frames utilising a combination of external and internal fixation, the latter comprising conventionalwires and pins only.ResultsIn the ECD group, pin tract infection was identified in 14.8% of cases. In these patients, infection occurred in 45.5% of all fixation elements; of these, 18.2% occurred around the ECD. In the WP (only wired and pins) group pin tract infection occurredin 29.2% cases. ECD fracture occurred in one case (3.7%). In the WP group, transosseous element breakage occurred in 3 cases(13.6%). In the treatment of periprosthetic fractures and deformities using the ECD, pin tract infection was seen in 16.7%. Inthe treatment of similar fractures and deformities not associated with an endoprosthesis, pin tract infections were seen in 21.5%of cases.ConclusionIn this study we have demonstrated that the ECD does not increase the number of complications specific to external fixation.All resultant complications applicable to the ECD were addressed by conservative measures, and did not affect the outcome.The use of the ECD eliminates complications and concerns in combined osteosynthesis such as obstruction and jamming of anintramedullary device; fretting wear due to contact with half pins or wires and endoprosthesis; loss of torsional control as seennot uncommonly with half pins; the reduction in frame stability due to the use of smaller pins; and the risk of pin or wire cut-outdue to eccentric placement.


  • Open Access

    Spring technique for correction of multilevel deformity using hexapod external fixator

    by Munetomo Takata, Leonid N Solomin, ElenaA Shchepkina, Fanil Sabirov, Konstantin L Korchagin, Hiroyuki Tsuchiya

    Context: Osteotomies in several parts of one long bone are recommended for correction of a long, curved, and wide-angled deformity. Hexapod external fixators (HEFs) allow for the single-stage correction of multiplanar deformity, but they are heavy, expensive, and requires continuous management of 12 struts, if at more than one level. Aims: We proposed the use of springs with HEF to support the intermediate ring. Deformity between the proximal and distal rings is corrected using one HEF, and the intermediate fragment is automatically corrected by the tension of the springs. Settings and Design: This was a retrospective descriptive study. Subjects and Methods: We treated seven males and eight females with 17 affected limbs. Four patients with familial hypophosphatemic rickets, five posttraumatic deformities, two osteogenesis imperfectas, three fibrous dysplasias, and one neurofibromatosis were included. The mean preoperative angle between the most proximal and distal fragments was 62.5°. First, small distraction at each level was initiated with one HEF fixed to the most proximal and distal rings, and Ilizarov hinges applied between the proximal and intermediate rings. Then, a set of three springs was applied for each interval between the rings. Gradual correction using HEF was performed, considering only the axes of the proximal and distal bone fragments. Results: Good alignment was achieved in all patients without severe complications. The mean correction period was 5.5 weeks and mean fixation period was 33.8 weeks. Conclusion: Combination of HEF and springs is capable of correcting severe deformity.