Anna Hayes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Anna Hayes has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- David D. McManus
Program in Digital Medicine, Department of Medicine, University of Massachusetts Chan Medical School, Worcester, MA, United States
6 shared publications - Alok Kapoor
Division of Hospital Medicine University of Massachusetts Chan Medical School Worcester Massachusetts USA
4 shared publications - Andreza Andrade
Department of Medicine University of Massachusetts Chan Medical School Worcester, MA United States
4 shared publications - Carl Possidente
Division of Medical Affairs Pfizer Inc New York, NY United States
4 shared publications - Kathleen M. Mazor
Meyers Primary Care Institute University of Massachusetts Medical School Worcester, MA United States
4 shared publications - Rozelle Hegeman-Dingle
Pfizer Inc, US Medical Affairs New York NY USA
4 shared publications
Latest Publications
- Open Access
- 19 November 2021
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 5 (2) , e27016
Usability and Perceived Usefulness of the AFib 2gether Mobile App in a Clinical Setting: Single-Arm Intervention Study
Background: Although the American Heart Association and other professional societies have recommended shared decision-making as a way for patients with atrial fibrillation (AF) or atrial flutter to make informed decisions about using anticoagulation (AC), the best method for facilitating shared decision-making remains uncertain. Objective: The aim of this study is to assess the AFib 2gether mobile app for usability, perceived usefulness, and the extent and nature of shared decision-making that occurred for clinical encounters between patients with AF and their cardiology providers in which the app was used. Methods: We identified patients visiting a cardiology provider between October 2019 and May 2020. We measured usability from patients and providers using the Mobile App Rating Scale. From the 8 items of the Mobile App Rating Scale, we reported the average score (out of 5) for domains of functionality, esthetics, and overall quality. We administered a 3-item questionnaire to patients relating to their perceived usefulness of the app and a separate 3-item questionnaire to providers to measure their perceived usefulness of the app. We performed a chart review to track the occurrence of AC within 6 months of the index visit. We also audio recorded a subset of the encounters to identify evidence of shared decision-making. Results: We facilitated shared decision-making visits for 37 patients visiting 13 providers. In terms of usability, patients’ average ratings of functionality, esthetics, and overall quality were 4.51 (SD 0.61), 4.26 (SD 0.51), and 4.24 (SD 0.89), respectively. In terms of usefulness, 41% (15/37) of patients agreed that the app improved their knowledge regarding AC, and 62% (23/37) agreed that the app helped clarify to their provider their preferences regarding AC. Among providers, 79% (27/34) agreed that the app helped clarify their patients’ preferences, 82% (28/34) agreed that the app saved them time, and 59% (20/34) agreed that the app helped their patients make decisions about AC. In addition, 32% (12/37) of patients started AC after their shared decision-making visits. We audio recorded 25 encounters. Of these, 84% (21/25) included the mention of AC for AF, 44% (11/25) included the discussion of multiple options for AC, 72% (18/25) included a provider recommendation for AC, and 48% (12/25) included the evidence of patient involvement in the discussion. Conclusions: Patients and providers rated the app with high usability and perceived usefulness. Moreover, one-third of the patients began AC, and approximately 50% (12/25) of the encounters showed evidence of patient involvement in decision-making. In the future, we plan to study the effect of the app on a larger sample and with a controlled study design. Trial Registration: ClinicalTrials.gov NCT04118270; https://clinicaltrials.gov/ct2/show/NCT04118270 International Registered Report Identifier (IRRID): RR2-21986
- 19 November 2021
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 5 (2) , e27016
Open AccessUsability and Perceived Usefulness of the AFib 2gether Mobile App in a Clinical Setting: Single-Arm Intervention Study
Background: Although the American Heart Association and other professional societies have recommended shared decision-making as a way for patients with atrial fibrillation (AF) or atrial flutter to make informed decisions about using anticoagulation (AC), the best method for facilitating shared decision-making remains uncertain. Objective: The aim of this study is to assess the AFib 2gether mobile app for usability, perceived usefulness, and the extent and nature of shared decision-making that occurred for clinical encounters between patients with AF and their cardiology providers in which the app was used. Methods: We identified patients visiting a cardiology provider between October 2019 and May 2020. We measured usability from patients and providers using the Mobile App Rating Scale. From the 8 items of the Mobile App Rating Scale, we reported the average score (out of 5) for domains of functionality, esthetics, and overall quality. We administered a 3-item questionnaire to patients relating to their perceived usefulness of the app and a separate 3-item questionnaire to providers to measure their perceived usefulness of the app. We performed a chart review to track the occurrence of AC within 6 months of the index visit. We also audio recorded a subset of the encounters to identify evidence of shared decision-making. Results: We facilitated shared decision-making visits for 37 patients visiting 13 providers. In terms of usability, patients’ average ratings of functionality, esthetics, and overall quality were 4.51 (SD 0.61), 4.26 (SD 0.51), and 4.24 (SD 0.89), respectively. In terms of usefulness, 41% (15/37) of patients agreed that the app improved their knowledge regarding AC, and 62% (23/37) agreed that the app helped clarify to their provider their preferences regarding AC. Among providers, 79% (27/34) agreed that the app helped clarify their patients’ preferences, 82% (28/34) agreed that the app saved them time, and 59% (20/34) agreed that the app helped their patients make decisions about AC. In addition, 32% (12/37) of patients started AC after their shared decision-making visits. We audio recorded 25 encounters. Of these, 84% (21/25) included the mention of AC for AF, 44% (11/25) included the discussion of multiple options for AC, 72% (18/25) included a provider recommendation for AC, and 48% (12/25) included the evidence of patient involvement in the discussion. Conclusions: Patients and providers rated the app with high usability and perceived usefulness. Moreover, one-third of the patients began AC, and approximately 50% (12/25) of the encounters showed evidence of patient involvement in decision-making. In the future, we plan to study the effect of the app on a larger sample and with a controlled study design. Trial Registration: ClinicalTrials.gov NCT04118270; https://clinicaltrials.gov/ct2/show/NCT04118270 International Registered Report Identifier (IRRID): RR2-21986
- Open Access
- 24 February 2021
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 10 (2) , e21986
Usability, Perceived Usefulness, and Shared Decision-Making Features of the AFib 2gether Mobile App: Protocol for a Single-Arm Intervention Study
Background: The Centers for Disease Control and Prevention has estimated that atrial fibrillation (AF) affects between 2.7 million and 6.1 million people in the United States. Those who have AF tend to have a much higher stroke risk than others. Although most individuals with AF benefit from anticoagulation (AC) therapy, a significant majority are hesitant to start it. To add, providers often struggle in helping patients negotiate the decision to start AC therapy. To assist in the communication between patients and providers regarding preferences and knowledge about AC therapy, different strategies are being used to try and solve this problem. In this research study, we will have patients and providers utilize the AFib 2gether app with hopes that it will create a platform for shared decision making regarding the prevention of stroke in patients with AF receiving AC therapy. Objective: The aim of our study is to measure several outcomes related to encounters between patients and their cardiology providers where AFib 2gether is used. These outcomes include usability and perceived usefulness of the app from the perspective of patients and providers. In addition, we will assess the extent and nature of shared decision making. Methods: Eligible patients and providers will evaluate the AFib 2gether mobile app for usability and perceived usefulness in facilitating shared decision making regarding understanding the patient’s risk of stroke and whether or not to start AC therapy. Both patients and providers will review the app and complete multiple questionnaires about the usability and perceived usefulness of the mobile app in a clinical setting. We will also audio-record a subset of encounters to assess for evidence of shared decision making. Results: Enrollment in the AFib 2gether shared decision-making study is still ongoing for both patients and providers. The first participant enrolled on November 22, 2019. Analysis and publishing of results are expected to be completed in spring 2021. Conclusions: The AFib 2gether app emerged from a desire to increase the ability of patients and providers to engage in shared decision making around understanding the risk of stroke and AC therapy. We anticipate that the AFib 2gether mobile app will facilitate patient discussion with their cardiologist and other providers. Additionally, we hope the study will help us identify barriers that providers face when placing patients on AC therapy. We aim to demonstrate the usability and perceived usefulness of the app with a future goal of testing the value of our approach in a larger sample of patients and providers at multiple medical centers across the country. Trial Registration: ClinicalTrials.gov NCT04118270; https://clinicaltrials.gov/ct2/show/NCT04118270 International Registered Report Identifier (IRRID): DERR1-10.2196/21986
- 24 February 2021
- Published by JMIR Publications Inc. in JMIR Research Protocols
- Vol. 10 (2) , e21986
Open AccessUsability, Perceived Usefulness, and Shared Decision-Making Features of the AFib 2gether Mobile App: Protocol for a Single-Arm Intervention Study
Background: The Centers for Disease Control and Prevention has estimated that atrial fibrillation (AF) affects between 2.7 million and 6.1 million people in the United States. Those who have AF tend to have a much higher stroke risk than others. Although most individuals with AF benefit from anticoagulation (AC) therapy, a significant majority are hesitant to start it. To add, providers often struggle in helping patients negotiate the decision to start AC therapy. To assist in the communication between patients and providers regarding preferences and knowledge about AC therapy, different strategies are being used to try and solve this problem. In this research study, we will have patients and providers utilize the AFib 2gether app with hopes that it will create a platform for shared decision making regarding the prevention of stroke in patients with AF receiving AC therapy. Objective: The aim of our study is to measure several outcomes related to encounters between patients and their cardiology providers where AFib 2gether is used. These outcomes include usability and perceived usefulness of the app from the perspective of patients and providers. In addition, we will assess the extent and nature of shared decision making. Methods: Eligible patients and providers will evaluate the AFib 2gether mobile app for usability and perceived usefulness in facilitating shared decision making regarding understanding the patient’s risk of stroke and whether or not to start AC therapy. Both patients and providers will review the app and complete multiple questionnaires about the usability and perceived usefulness of the mobile app in a clinical setting. We will also audio-record a subset of encounters to assess for evidence of shared decision making. Results: Enrollment in the AFib 2gether shared decision-making study is still ongoing for both patients and providers. The first participant enrolled on November 22, 2019. Analysis and publishing of results are expected to be completed in spring 2021. Conclusions: The AFib 2gether app emerged from a desire to increase the ability of patients and providers to engage in shared decision making around understanding the risk of stroke and AC therapy. We anticipate that the AFib 2gether mobile app will facilitate patient discussion with their cardiologist and other providers. Additionally, we hope the study will help us identify barriers that providers face when placing patients on AC therapy. We aim to demonstrate the usability and perceived usefulness of the app with a future goal of testing the value of our approach in a larger sample of patients and providers at multiple medical centers across the country. Trial Registration: ClinicalTrials.gov NCT04118270; https://clinicaltrials.gov/ct2/show/NCT04118270 International Registered Report Identifier (IRRID): DERR1-10.2196/21986
- Open Access
- 20 January 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Usability and Perceived Usefulness of the AFib 2gether Mobile App in a Clinical Setting: Single-Arm Intervention Study (Preprint)
BACKGROUND Although the American Heart Association and other professional societies have recommended shared decision-making as a way for patients with atrial fibrillation (AF) or atrial flutter to make informed decisions about using anticoagulation (AC), the best method for facilitating shared decision-making remains uncertain. OBJECTIVE The aim of this study is to assess the AFib 2gether mobile app for usability, perceived usefulness, and the extent and nature of shared decision-making that occurred for clinical encounters between patients with AF and their cardiology providers in which the app was used. METHODS We identified patients visiting a cardiology provider between October 2019 and May 2020. We measured usability from patients and providers using the Mobile App Rating Scale. From the 8 items of the Mobile App Rating Scale, we reported the average score (out of 5) for domains of functionality, esthetics, and overall quality. We administered a 3-item questionnaire to patients relating to their perceived usefulness of the app and a separate 3-item questionnaire to providers to measure their perceived usefulness of the app. We performed a chart review to track the occurrence of AC within 6 months of the index visit. We also audio recorded a subset of the encounters to identify evidence of shared decision-making. RESULTS We facilitated shared decision-making visits for 37 patients visiting 13 providers. In terms of usability, patients’ average ratings of functionality, esthetics, and overall quality were 4.51 (SD 0.61), 4.26 (SD 0.51), and 4.24 (SD 0.89), respectively. In terms of usefulness, 41% (15/37) of patients agreed that the app improved their knowledge regarding AC, and 62% (23/37) agreed that the app helped clarify to their provider their preferences regarding AC. Among providers, 79% (27/34) agreed that the app helped clarify their patients’ preferences, 82% (28/34) agreed that the app saved them time, and 59% (20/34) agreed that the app helped their patients make decisions about AC. In addition, 32% (12/37) of patients started AC after their shared decision-making visits. We audio recorded 25 encounters. Of these, 84% (21/25) included the mention of AC for AF, 44% (11/25) included the discussion of multiple options for AC, 72% (18/25) included a provider recommendation for AC, and 48% (12/25) included the evidence of patient involvement in the discussion. CONCLUSIONS Patients and providers rated the app with high usability and perceived usefulness. Moreover, one-third of the patients began AC, and approximately 50% (12/25) of the encounters showed evidence of patient involvement in decision-making. In the future, we plan to study the effect of the app on a larger sample and with a controlled study design. CLINICALTRIAL ClinicalTrials.gov NCT04118270; https://clinicaltrials.gov/ct2/show/NCT04118270 INTERNATIONAL REGISTERED REPORT RR2-21986
- 20 January 2021
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessUsability and Perceived Usefulness of the AFib 2gether Mobile App in a Clinical Setting: Single-Arm Intervention Study (Preprint)
BACKGROUND Although the American Heart Association and other professional societies have recommended shared decision-making as a way for patients with atrial fibrillation (AF) or atrial flutter to make informed decisions about using anticoagulation (AC), the best method for facilitating shared decision-making remains uncertain. OBJECTIVE The aim of this study is to assess the AFib 2gether mobile app for usability, perceived usefulness, and the extent and nature of shared decision-making that occurred for clinical encounters between patients with AF and their cardiology providers in which the app was used. METHODS We identified patients visiting a cardiology provider between October 2019 and May 2020. We measured usability from patients and providers using the Mobile App Rating Scale. From the 8 items of the Mobile App Rating Scale, we reported the average score (out of 5) for domains of functionality, esthetics, and overall quality. We administered a 3-item questionnaire to patients relating to their perceived usefulness of the app and a separate 3-item questionnaire to providers to measure their perceived usefulness of the app. We performed a chart review to track the occurrence of AC within 6 months of the index visit. We also audio recorded a subset of the encounters to identify evidence of shared decision-making. RESULTS We facilitated shared decision-making visits for 37 patients visiting 13 providers. In terms of usability, patients’ average ratings of functionality, esthetics, and overall quality were 4.51 (SD 0.61), 4.26 (SD 0.51), and 4.24 (SD 0.89), respectively. In terms of usefulness, 41% (15/37) of patients agreed that the app improved their knowledge regarding AC, and 62% (23/37) agreed that the app helped clarify to their provider their preferences regarding AC. Among providers, 79% (27/34) agreed that the app helped clarify their patients’ preferences, 82% (28/34) agreed that the app saved them time, and 59% (20/34) agreed that the app helped their patients make decisions about AC. In addition, 32% (12/37) of patients started AC after their shared decision-making visits. We audio recorded 25 encounters. Of these, 84% (21/25) included the mention of AC for AF, 44% (11/25) included the discussion of multiple options for AC, 72% (18/25) included a provider recommendation for AC, and 48% (12/25) included the evidence of patient involvement in the discussion. CONCLUSIONS Patients and providers rated the app with high usability and perceived usefulness. Moreover, one-third of the patients began AC, and approximately 50% (12/25) of the encounters showed evidence of patient involvement in decision-making. In the future, we plan to study the effect of the app on a larger sample and with a controlled study design. CLINICALTRIAL ClinicalTrials.gov NCT04118270; https://clinicaltrials.gov/ct2/show/NCT04118270 INTERNATIONAL REGISTERED REPORT RR2-21986
- Open Access
- 17 September 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Usability, Perceived Usefulness, and Shared Decision-Making Features of the AFib 2gether Mobile App: Protocol for a Single-Arm Intervention Study (Preprint)
BACKGROUND The Centers for Disease Control and Prevention has estimated that atrial fibrillation (AF) affects between 2.7 million and 6.1 million people in the United States. Those who have AF tend to have a much higher stroke risk than others. Although most individuals with AF benefit from anticoagulation (AC) therapy, a significant majority are hesitant to start it. To add, providers often struggle in helping patients negotiate the decision to start AC therapy. To assist in the communication between patients and providers regarding preferences and knowledge about AC therapy, different strategies are being used to try and solve this problem. In this research study, we will have patients and providers utilize the AFib 2gether app with hopes that it will create a platform for shared decision making regarding the prevention of stroke in patients with AF receiving AC therapy. OBJECTIVE The aim of our study is to measure several outcomes related to encounters between patients and their cardiology providers where AFib 2gether is used. These outcomes include usability and perceived usefulness of the app from the perspective of patients and providers. In addition, we will assess the extent and nature of shared decision making. METHODS Eligible patients and providers will evaluate the AFib 2gether mobile app for usability and perceived usefulness in facilitating shared decision making regarding understanding the patient’s risk of stroke and whether or not to start AC therapy. Both patients and providers will review the app and complete multiple questionnaires about the usability and perceived usefulness of the mobile app in a clinical setting. We will also audio-record a subset of encounters to assess for evidence of shared decision making. RESULTS Enrollment in the AFib 2gether shared decision-making study is still ongoing for both patients and providers. The first participant enrolled on November 22, 2019. Analysis and publishing of results are expected to be completed in spring 2021. CONCLUSIONS The AFib 2gether app emerged from a desire to increase the ability of patients and providers to engage in shared decision making around understanding the risk of stroke and AC therapy. We anticipate that the AFib 2gether mobile app will facilitate patient discussion with their cardiologist and other providers. Additionally, we hope the study will help us identify barriers that providers face when placing patients on AC therapy. We aim to demonstrate the usability and perceived usefulness of the app with a future goal of testing the value of our approach in a larger sample of patients and providers at multiple medical centers across the country. CLINICALTRIAL ClinicalTrials.gov NCT04118270; https://clinicaltrials.gov/ct2/show/NCT04118270 INTERNATIONAL REGISTERED REPORT DERR1-10.2196/21986
- 17 September 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessUsability, Perceived Usefulness, and Shared Decision-Making Features of the AFib 2gether Mobile App: Protocol for a Single-Arm Intervention Study (Preprint)
BACKGROUND The Centers for Disease Control and Prevention has estimated that atrial fibrillation (AF) affects between 2.7 million and 6.1 million people in the United States. Those who have AF tend to have a much higher stroke risk than others. Although most individuals with AF benefit from anticoagulation (AC) therapy, a significant majority are hesitant to start it. To add, providers often struggle in helping patients negotiate the decision to start AC therapy. To assist in the communication between patients and providers regarding preferences and knowledge about AC therapy, different strategies are being used to try and solve this problem. In this research study, we will have patients and providers utilize the AFib 2gether app with hopes that it will create a platform for shared decision making regarding the prevention of stroke in patients with AF receiving AC therapy. OBJECTIVE The aim of our study is to measure several outcomes related to encounters between patients and their cardiology providers where AFib 2gether is used. These outcomes include usability and perceived usefulness of the app from the perspective of patients and providers. In addition, we will assess the extent and nature of shared decision making. METHODS Eligible patients and providers will evaluate the AFib 2gether mobile app for usability and perceived usefulness in facilitating shared decision making regarding understanding the patient’s risk of stroke and whether or not to start AC therapy. Both patients and providers will review the app and complete multiple questionnaires about the usability and perceived usefulness of the mobile app in a clinical setting. We will also audio-record a subset of encounters to assess for evidence of shared decision making. RESULTS Enrollment in the AFib 2gether shared decision-making study is still ongoing for both patients and providers. The first participant enrolled on November 22, 2019. Analysis and publishing of results are expected to be completed in spring 2021. CONCLUSIONS The AFib 2gether app emerged from a desire to increase the ability of patients and providers to engage in shared decision making around understanding the risk of stroke and AC therapy. We anticipate that the AFib 2gether mobile app will facilitate patient discussion with their cardiologist and other providers. Additionally, we hope the study will help us identify barriers that providers face when placing patients on AC therapy. We aim to demonstrate the usability and perceived usefulness of the app with a future goal of testing the value of our approach in a larger sample of patients and providers at multiple medical centers across the country. CLINICALTRIAL ClinicalTrials.gov NCT04118270; https://clinicaltrials.gov/ct2/show/NCT04118270 INTERNATIONAL REGISTERED REPORT DERR1-10.2196/21986
- Open Access
- 27 August 2020
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 8 (8) , e18715
Machine Learning Model Based on Transthoracic Bioimpedance and Heart Rate Variability for Lung Fluid Accumulation Detection: Prospective Clinical Study
Background: Accumulation of excess body fluid and autonomic dysregulation are clinically important characteristics of acute decompensated heart failure. We hypothesized that transthoracic bioimpedance, a noninvasive, simple method for measuring fluid retention in lungs, and heart rate variability, an assessment of autonomic function, can be used for detection of fluid accumulation in patients with acute decompensated heart failure. Objective: We aimed to evaluate the performance of transthoracic bioimpedance and heart rate variability parameters obtained using a fluid accumulation vest with carbon black–polydimethylsiloxane dry electrodes in a prospective clinical study (System for Heart Failure Identification Using an External Lung Fluid Device; SHIELD). Methods: We computed 15 parameters: 8 were calculated from the model to fit Cole-Cole plots from transthoracic bioimpedance measurements (extracellular, intracellular, intracellular-extracellular difference, and intracellular-extracellular parallel circuit resistances as well as fitting error, resonance frequency, tissue heterogeneity, and cellular membrane capacitance), and 7 were based on linear (mean heart rate, low-frequency components of heart rate variability, high-frequency components of heart rate variability, normalized low-frequency components of heart rate variability, normalized high-frequency components of heart rate variability) and nonlinear (principal dynamic mode index of sympathetic function, and principal dynamic mode index of parasympathetic function) analysis of heart rate variability. We compared the values of these parameters between 3 participant data sets: control (n=32, patients who did not have heart failure), baseline (n=23, patients with acute decompensated heart failure taken at the time of admittance to the hospital), and discharge (n=17, patients with acute decompensated heart failure taken at the time of discharge from hospital). We used several machine learning approaches to classify participants with fluid accumulation (baseline) and without fluid accumulation (control and discharge), termed with fluid and without fluid groups, respectively. Results: Among the 15 parameters, 3 transthoracic bioimpedance (extracellular resistance, R0; difference in extracellular-intracellular resistance, R0 – R∞, and tissue heterogeneity, α) and 3 heart rate variability (high-frequency, normalized low-frequency, and normalized high-frequency components) parameters were found to be the most discriminatory between groups (patients with and patients without heart failure). R0 and R0 – R∞ had significantly lower values for patients with heart failure than for those without heart failure (R0: P=.006; R0 – R∞: P=.001), indicating that a higher volume of fluids accumulated in the lungs of patients with heart failure. A cubic support vector machine model using the 5 parameters achieved an accuracy of 92% for with fluid and without fluid group classification. The transthoracic bioimpedance parameters were related to intra- and extracellular fluid, whereas the heart rate variability parameters were mostly related to sympathetic activation. Conclusions: This is useful, for instance, for an in-home diagnostic wearable to detect fluid accumulation. Results suggest that fluid accumulation, and subsequently acute decompensated heart failure detection, could be performed using transthoracic bioimpedance and heart rate variability measurements acquired with a wearable vest.
- 27 August 2020
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 8 (8) , e18715
Open AccessMachine Learning Model Based on Transthoracic Bioimpedance and Heart Rate Variability for Lung Fluid Accumulation Detection: Prospective Clinical Study
Background: Accumulation of excess body fluid and autonomic dysregulation are clinically important characteristics of acute decompensated heart failure. We hypothesized that transthoracic bioimpedance, a noninvasive, simple method for measuring fluid retention in lungs, and heart rate variability, an assessment of autonomic function, can be used for detection of fluid accumulation in patients with acute decompensated heart failure. Objective: We aimed to evaluate the performance of transthoracic bioimpedance and heart rate variability parameters obtained using a fluid accumulation vest with carbon black–polydimethylsiloxane dry electrodes in a prospective clinical study (System for Heart Failure Identification Using an External Lung Fluid Device; SHIELD). Methods: We computed 15 parameters: 8 were calculated from the model to fit Cole-Cole plots from transthoracic bioimpedance measurements (extracellular, intracellular, intracellular-extracellular difference, and intracellular-extracellular parallel circuit resistances as well as fitting error, resonance frequency, tissue heterogeneity, and cellular membrane capacitance), and 7 were based on linear (mean heart rate, low-frequency components of heart rate variability, high-frequency components of heart rate variability, normalized low-frequency components of heart rate variability, normalized high-frequency components of heart rate variability) and nonlinear (principal dynamic mode index of sympathetic function, and principal dynamic mode index of parasympathetic function) analysis of heart rate variability. We compared the values of these parameters between 3 participant data sets: control (n=32, patients who did not have heart failure), baseline (n=23, patients with acute decompensated heart failure taken at the time of admittance to the hospital), and discharge (n=17, patients with acute decompensated heart failure taken at the time of discharge from hospital). We used several machine learning approaches to classify participants with fluid accumulation (baseline) and without fluid accumulation (control and discharge), termed with fluid and without fluid groups, respectively. Results: Among the 15 parameters, 3 transthoracic bioimpedance (extracellular resistance, R0; difference in extracellular-intracellular resistance, R0 – R∞, and tissue heterogeneity, α) and 3 heart rate variability (high-frequency, normalized low-frequency, and normalized high-frequency components) parameters were found to be the most discriminatory between groups (patients with and patients without heart failure). R0 and R0 – R∞ had significantly lower values for patients with heart failure than for those without heart failure (R0: P=.006; R0 – R∞: P=.001), indicating that a higher volume of fluids accumulated in the lungs of patients with heart failure. A cubic support vector machine model using the 5 parameters achieved an accuracy of 92% for with fluid and without fluid group classification. The transthoracic bioimpedance parameters were related to intra- and extracellular fluid, whereas the heart rate variability parameters were mostly related to sympathetic activation. Conclusions: This is useful, for instance, for an in-home diagnostic wearable to detect fluid accumulation. Results suggest that fluid accumulation, and subsequently acute decompensated heart failure detection, could be performed using transthoracic bioimpedance and heart rate variability measurements acquired with a wearable vest.
- Open Access
- 13 March 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Machine Learning Model Based on Transthoracic Bioimpedance and Heart Rate Variability for Lung Fluid Accumulation Detection: Prospective Clinical Study (Preprint)
BACKGROUND Accumulation of excess body fluid and autonomic dysregulation are clinically important characteristics of acute decompensated heart failure. We hypothesized that transthoracic bioimpedance, a noninvasive, simple method for measuring fluid retention in lungs, and heart rate variability, an assessment of autonomic function, can be used for detection of fluid accumulation in patients with acute decompensated heart failure. OBJECTIVE We aimed to evaluate the performance of transthoracic bioimpedance and heart rate variability parameters obtained using a fluid accumulation vest with carbon black–polydimethylsiloxane dry electrodes in a prospective clinical study (System for Heart Failure Identification Using an External Lung Fluid Device; SHIELD). METHODS We computed 15 parameters: 8 were calculated from the model to fit Cole-Cole plots from transthoracic bioimpedance measurements (extracellular, intracellular, intracellular-extracellular difference, and intracellular-extracellular parallel circuit resistances as well as fitting error, resonance frequency, tissue heterogeneity, and cellular membrane capacitance), and 7 were based on linear (mean heart rate, low-frequency components of heart rate variability, high-frequency components of heart rate variability, normalized low-frequency components of heart rate variability, normalized high-frequency components of heart rate variability) and nonlinear (principal dynamic mode index of sympathetic function, and principal dynamic mode index of parasympathetic function) analysis of heart rate variability. We compared the values of these parameters between 3 participant data sets: control (n=32, patients who did not have heart failure), baseline (n=23, patients with acute decompensated heart failure taken at the time of admittance to the hospital), and discharge (n=17, patients with acute decompensated heart failure taken at the time of discharge from hospital). We used several machine learning approaches to classify participants with fluid accumulation (baseline) and without fluid accumulation (control and discharge), termed with fluid and without fluid groups, respectively. RESULTS Among the 15 parameters, 3 transthoracic bioimpedance (extracellular resistance, R0; difference in extracellular-intracellular resistance, R0 – R∞, and tissue heterogeneity, α) and 3 heart rate variability (high-frequency, normalized low-frequency, and normalized high-frequency components) parameters were found to be the most discriminatory between groups (patients with and patients without heart failure). R0 and R0 – R∞ had significantly lower values for patients with heart failure than for those without heart failure (R0: P=.006; R0 – R∞: P=.001), indicating that a higher volume of fluids accumulated in the lungs of patients with heart failure. A cubic support vector machine model using the 5 parameters achieved an accuracy of 92% for with fluid and without fluid group classification. The transthoracic bioimpedance parameters were related to intra- and extracellular fluid, whereas the heart rate variability parameters were mostly related to sympathetic activation. CONCLUSIONS This is useful, for instance, for an in-home diagnostic wearable to detect fluid accumulation. Results suggest that fluid accumulation, and subsequently acute decompensated heart failure detection, could be performed using transthoracic bioimpedance and heart rate variability measurements acquired with a wearable vest.
- 13 March 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessMachine Learning Model Based on Transthoracic Bioimpedance and Heart Rate Variability for Lung Fluid Accumulation Detection: Prospective Clinical Study (Preprint)
BACKGROUND Accumulation of excess body fluid and autonomic dysregulation are clinically important characteristics of acute decompensated heart failure. We hypothesized that transthoracic bioimpedance, a noninvasive, simple method for measuring fluid retention in lungs, and heart rate variability, an assessment of autonomic function, can be used for detection of fluid accumulation in patients with acute decompensated heart failure. OBJECTIVE We aimed to evaluate the performance of transthoracic bioimpedance and heart rate variability parameters obtained using a fluid accumulation vest with carbon black–polydimethylsiloxane dry electrodes in a prospective clinical study (System for Heart Failure Identification Using an External Lung Fluid Device; SHIELD). METHODS We computed 15 parameters: 8 were calculated from the model to fit Cole-Cole plots from transthoracic bioimpedance measurements (extracellular, intracellular, intracellular-extracellular difference, and intracellular-extracellular parallel circuit resistances as well as fitting error, resonance frequency, tissue heterogeneity, and cellular membrane capacitance), and 7 were based on linear (mean heart rate, low-frequency components of heart rate variability, high-frequency components of heart rate variability, normalized low-frequency components of heart rate variability, normalized high-frequency components of heart rate variability) and nonlinear (principal dynamic mode index of sympathetic function, and principal dynamic mode index of parasympathetic function) analysis of heart rate variability. We compared the values of these parameters between 3 participant data sets: control (n=32, patients who did not have heart failure), baseline (n=23, patients with acute decompensated heart failure taken at the time of admittance to the hospital), and discharge (n=17, patients with acute decompensated heart failure taken at the time of discharge from hospital). We used several machine learning approaches to classify participants with fluid accumulation (baseline) and without fluid accumulation (control and discharge), termed with fluid and without fluid groups, respectively. RESULTS Among the 15 parameters, 3 transthoracic bioimpedance (extracellular resistance, R0; difference in extracellular-intracellular resistance, R0 – R∞, and tissue heterogeneity, α) and 3 heart rate variability (high-frequency, normalized low-frequency, and normalized high-frequency components) parameters were found to be the most discriminatory between groups (patients with and patients without heart failure). R0 and R0 – R∞ had significantly lower values for patients with heart failure than for those without heart failure (R0: P=.006; R0 – R∞: P=.001), indicating that a higher volume of fluids accumulated in the lungs of patients with heart failure. A cubic support vector machine model using the 5 parameters achieved an accuracy of 92% for with fluid and without fluid group classification. The transthoracic bioimpedance parameters were related to intra- and extracellular fluid, whereas the heart rate variability parameters were mostly related to sympathetic activation. CONCLUSIONS This is useful, for instance, for an in-home diagnostic wearable to detect fluid accumulation. Results suggest that fluid accumulation, and subsequently acute decompensated heart failure detection, could be performed using transthoracic bioimpedance and heart rate variability measurements acquired with a wearable vest.