Tilemachos Paraskeuopoulos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tilemachos Paraskeuopoulos has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Theodosios Saranteas
From the Department of Anaesthesiology, General Hospital of Laconia, Molaoi and the Department of Anatomy and the 2nd Department of Anaesthesiology, School of Medicine, University of Athens, Athens, Greece
3 shared publicationsGeorgia Kostopanagiotou
Department of Anesthesia and Cardiovascular Critical Care, University of Athens, Attikon University Hospital of Athens, Athens, Greece
2 shared publicationsSophia Anagnostopoulou
Department of Anatomy, University of Athens, School of Medicine, Athens, Greece
2 shared publicationsAreti Adoni
Department of Anesthesia and Cardiovascular Critical Care, University of Athens, Attikon University Hospital of Athens, Athens, Greece
1 shared publicationDimitrios Mastrokalos
Department of Orthopedic, School of Medicine, University of Athens, Attikon University Hospital of Athens, Athens, Greece
1 shared publicationDimitrios Papadimas
Department of Anatomy, School of Medicine, University of Athens, Athens, Greece
1 shared publication
Latest Publications
- 1 May 2015
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 32 (5) , 368-369
Anatomical basis of the various spread patterns around the femoral nerve in the inguinal region
- 1 May 2015
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 32 (5) , 368-369
Anatomical basis of the various spread patterns around the femoral nerve in the inguinal region
- Open Access
- 1 January 2014
- Published by Medknow in Journal of Anaesthesiology Clinical Pharmacology
- Vol. 30 (3) , 378-82
Prospective randomized comparison between ultrasound-guided saphenous nerve block within and distal to the adductor canal with low volume of local anesthetic
Background and Aims: The anatomic site and the volume of local anesthetic needed for an ultrasound-guided saphenous nerve block differ in the literature. The purpose of this study was to examine the effect of two different ultrasound-guided low volume injections of local anesthetic on saphenous and vastus medialis nerves. Materials and Methods: Recruited patients (N = 48) scheduled for orthopedic surgery were randomized in two groups; Group distal adductor canal (DAC): Ultrasound-guided injection (5 ml of local anesthetic) distal to the inferior foramina of the adductor canal. Group adductor canal (AC): Ultrasound-guided injection (5 ml local anesthetic) within the adductor canal. Following the injection of local anesthetic, block progression was monitored in 5 min intervals for 15 min in the sartorial branches of the saphenous nerve and vastus medialis nerve. Results: Twenty two patients in each group completed the study. Complete block of the saphenous nerve was observed in 55% and 59% in Group AC and DAC, respectively (P = 0.88). The proportion of patients with vastus medialis weakness at 15 min in Group AC, 36%, was significantly higher than in Group DAC (0/22), (P = 0.021). Conclusions: Low volume of local anesthetic injected within the adductor canal or distally its inferior foramina leads to moderate success rate of the saphenous nerve block, while only the injection within the adductor canal may result in vastus medialis nerve motor block.
- 1 January 2014
- Published by Medknow in Journal of Anaesthesiology Clinical Pharmacology
- Vol. 30 (3) , 378-82
Open AccessProspective randomized comparison between ultrasound-guided saphenous nerve block within and distal to the adductor canal with low volume of local anesthetic
Background and Aims: The anatomic site and the volume of local anesthetic needed for an ultrasound-guided saphenous nerve block differ in the literature. The purpose of this study was to examine the effect of two different ultrasound-guided low volume injections of local anesthetic on saphenous and vastus medialis nerves. Materials and Methods: Recruited patients (N = 48) scheduled for orthopedic surgery were randomized in two groups; Group distal adductor canal (DAC): Ultrasound-guided injection (5 ml of local anesthetic) distal to the inferior foramina of the adductor canal. Group adductor canal (AC): Ultrasound-guided injection (5 ml local anesthetic) within the adductor canal. Following the injection of local anesthetic, block progression was monitored in 5 min intervals for 15 min in the sartorial branches of the saphenous nerve and vastus medialis nerve. Results: Twenty two patients in each group completed the study. Complete block of the saphenous nerve was observed in 55% and 59% in Group AC and DAC, respectively (P = 0.88). The proportion of patients with vastus medialis weakness at 15 min in Group AC, 36%, was significantly higher than in Group DAC (0/22), (P = 0.021). Conclusions: Low volume of local anesthetic injected within the adductor canal or distally its inferior foramina leads to moderate success rate of the saphenous nerve block, while only the injection within the adductor canal may result in vastus medialis nerve motor block.
- 16 July 2010
- Published by Wiley in Clinical Anatomy
- Vol. 23 (7) , 840-847
Thoracic paravertebral spread using two different ultrasound‐guided intercostal injection techniques in human cadavers
The continuity between the intercostal and paravertebral space has been established by several studies. In this study, the paravertebral spread of a colored dye was attempted with two different ultrasound‐guided techniques. The posterior area of the trunk was scanned with a linear probe between the level of the fifth and the seventh thoracic vertebrae in eleven embalmed human cadavers. In the first technique, the probe was placed transversely below the inferior margin of the rib, and a needle was inserted between the internal intercostal membrane and the pleura. In the second technique, the probe was placed longitudinally at the intercostal space 5 cm lateral to the spinous processes, and the needle was inserted between the internal intercostal membrane and the pleura. In both techniques, 1 ml of methylene blue was injected, and both the intercostal and paravertebral spaces were prepared. In total, 33 injections were performed: 19 with the transverse technique and 14 with the longitudinal technique. Successful spread of the dye to the thoracic paravertebral space was recorded in 89.5% cases using the transverse technique and 92.8% cases using the longitudinal technique. No intrapleural spread of the dye was recorded in either technique. Ultrasound‐guided injection into the intercostal space may offer an alternative approach to the thoracic paravertebral space. Clin. Anat. 23:840–847, 2010.
- 16 July 2010
- Published by Wiley in Clinical Anatomy
- Vol. 23 (7) , 840-847
Thoracic paravertebral spread using two different ultrasound‐guided intercostal injection techniques in human cadavers
The continuity between the intercostal and paravertebral space has been established by several studies. In this study, the paravertebral spread of a colored dye was attempted with two different ultrasound‐guided techniques. The posterior area of the trunk was scanned with a linear probe between the level of the fifth and the seventh thoracic vertebrae in eleven embalmed human cadavers. In the first technique, the probe was placed transversely below the inferior margin of the rib, and a needle was inserted between the internal intercostal membrane and the pleura. In the second technique, the probe was placed longitudinally at the intercostal space 5 cm lateral to the spinous processes, and the needle was inserted between the internal intercostal membrane and the pleura. In both techniques, 1 ml of methylene blue was injected, and both the intercostal and paravertebral spaces were prepared. In total, 33 injections were performed: 19 with the transverse technique and 14 with the longitudinal technique. Successful spread of the dye to the thoracic paravertebral space was recorded in 89.5% cases using the transverse technique and 92.8% cases using the longitudinal technique. No intrapleural spread of the dye was recorded in either technique. Ultrasound‐guided injection into the intercostal space may offer an alternative approach to the thoracic paravertebral space. Clin. Anat. 23:840–847, 2010.
- 28 August 2009
- Published by Wiley in Clinical Anatomy
- Vol. 22 (7) , 826-833
Cutaneous perforators of the peroneal artery: Cadaveric study with implications in the design of the osteocutaneous free fibular flap
Bilateral dissection of 15 formalin embalmed cadaver legs was performed in order to study the anatomic pattern of the peroneal artery (PA) and its cutaneous perforating vessels (CB). The total number of CB from the PA was 125 or an average of 4.17 branches per leg. CB were distributed in the superoinferior axis between 18.25 and 84.25% of the length of the fibula and their average length was 5 ± 1.8 cm. 86/125 (68.8%) of the CB were classified as myocutaneous branches (MC) that penetrated muscle before reaching the skin, whereas 39/125 (31.2%) were septocutaneous branches (SC) that passed through the intermuscular septum. The mean distance between the posterior border of the fibula and the site where the perforators emerged was 1.88 ± 0.79 cm for the SC and 1.21 ± 0.87 cm for the MC. These anatomic findings should encourage the surgeon to design the skin paddle in the boundary between the middle and the distal third of the fibular length about 2 cm behind the posterior fibular border on the posterolateral leg, where the number of CB is maximal. Clin. Anat. 22:826–833, 2009.
- 28 August 2009
- Published by Wiley in Clinical Anatomy
- Vol. 22 (7) , 826-833
Cutaneous perforators of the peroneal artery: Cadaveric study with implications in the design of the osteocutaneous free fibular flap
Bilateral dissection of 15 formalin embalmed cadaver legs was performed in order to study the anatomic pattern of the peroneal artery (PA) and its cutaneous perforating vessels (CB). The total number of CB from the PA was 125 or an average of 4.17 branches per leg. CB were distributed in the superoinferior axis between 18.25 and 84.25% of the length of the fibula and their average length was 5 ± 1.8 cm. 86/125 (68.8%) of the CB were classified as myocutaneous branches (MC) that penetrated muscle before reaching the skin, whereas 39/125 (31.2%) were septocutaneous branches (SC) that passed through the intermuscular septum. The mean distance between the posterior border of the fibula and the site where the perforators emerged was 1.88 ± 0.79 cm for the SC and 1.21 ± 0.87 cm for the MC. These anatomic findings should encourage the surgeon to design the skin paddle in the boundary between the middle and the distal third of the fibular length about 2 cm behind the posterior fibular border on the posterolateral leg, where the number of CB is maximal. Clin. Anat. 22:826–833, 2009.