Bijan Shekarriz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bijan Shekarriz has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
Jyoti Upadhyay
From the Department of Urology, State University of New York, Upstate Medical University, Syracuse, New York
2 shared publicationsGaurang Shah
From the Department of Urology, State University of New York, Upstate Medical University, Syracuse, New York
1 shared publicationMichael A.S. Jewett
1 shared publication
Latest Publications
- 1 May 2005
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 2 (3) , 287-291
Hydro-Jet technology in urologic surgery
Hydro-Jet technology utilizes an extremely thin, high-pressure stream of water. This technology has been routinely used in industry as a cutting tool for different materials such as metal, ceramic, wood and glass. Recently, Hydro-Jet technology has been used for dissection and resection during open and laparoscopic surgical procedures. A high-pressure jet of water allows selective dissection and isolation of vital structures such as blood vessels and nerves. This has resulted in improved dissection and decreased complication rate in recent experimental and clinical studies. This technology has been successfully applied during open and laparoscopic partial nephrectomy, cholecystecomy and retroperitoneal lymphadenectomy.
- 1 May 2005
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 2 (3) , 287-291
Hydro-Jet technology in urologic surgery
Hydro-Jet technology utilizes an extremely thin, high-pressure stream of water. This technology has been routinely used in industry as a cutting tool for different materials such as metal, ceramic, wood and glass. Recently, Hydro-Jet technology has been used for dissection and resection during open and laparoscopic surgical procedures. A high-pressure jet of water allows selective dissection and isolation of vital structures such as blood vessels and nerves. This has resulted in improved dissection and decreased complication rate in recent experimental and clinical studies. This technology has been successfully applied during open and laparoscopic partial nephrectomy, cholecystecomy and retroperitoneal lymphadenectomy.
- 1 July 2004
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 172 (1) , 54-57
IMPACT OF TEMPORARY HILAR CLAMPING DURING LAPAROSCOPIC PARTIAL NEPHRECTOMY ON POSTOPERATIVE RENAL FUNCTION: A PROSPECTIVE STUDY
Purpose: Laparoscopic partial nephrectomy for small renal tumors has been increasingly performed in the last few years. We prospectively evaluated preoperative and postoperative differentia...
- 1 July 2004
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 172 (1) , 54-57
IMPACT OF TEMPORARY HILAR CLAMPING DURING LAPAROSCOPIC PARTIAL NEPHRECTOMY ON POSTOPERATIVE RENAL FUNCTION: A PROSPECTIVE STUDY
Purpose: Laparoscopic partial nephrectomy for small renal tumors has been increasingly performed in the last few years. We prospectively evaluated preoperative and postoperative differentia...
- 1 April 2004
- Published by SAGE Publications in Journal of Endourology
- Vol. 18 (3) , 273-276
Nerve-Sparing Retroperitoneal Lymphadenectomy Using Hydro-Jet Dissection: Initial Experience
Background and Purpose: Nerve-sparing retroperitoneal lymphadenectomy (RPL) is performed in a significant number of patients to preserve ejaculation after treatment for testicular cancer. Identification and preservation of the sympathetic nerves may be challenging. Hydro-Jet technology has been utilized for various surgical applications. A small high-pressure stream of water is used to delineate surgical planes, with preservation of vascular and neural structures. We have examined the utility of this technology for RPL in a porcine model and in human subjects. Materials and Method: A Helix Hydro-Jet device (Erbe, USA) was used for all procedures. A high-pressure water-jet stream is directed through a small nozzle with a 120-μm inner radius for soft-tissue dissection. The upper pressure limit (range 0-2175 psi) is set using a digital monitor. The jet is initiated using a foot pedal, and the actual pressure is monitored. A pressure of 360 to 400 psi was used for experimental studies, which was decreased to 255 to 300 psi for human use. Three pigs underwent RPL using this technique. Subsequently, RPL was performed in five men with testicular cancer, being primary in two and postchemotherapy in three. The primary diagnosis was seminoma in one and non-seminomatous cancer in four. The patient with seminoma had a residual mass after chemotherapy. Results: The procedures were completed successfully in all subjects. There were no intraoperative or postoperative complications. Hydro-Jet dissection permitted tissue selectivity, with preservation of vascular structures and sympathetic nerves. The soft tissue and lymphatics were removed with the high-pressure water stream assisted by blunt dissection. The nerve fibers were grossly resistant to the pressure used and were isolated individually. Dissection around the great vessels appeared to be safe, and no injury was observed with direct application of the jet. Lumbar arteries and veins and accessory vessels could be isolated safely. The estimated blood loss was minimal in animals and 300 to 800 mL in humans. Conclusions: Hydro-Jet dissection demonstrated tissue selectivity using a pressure range of 255 to 300 psi in humans. The vascular structures and sympathetic nerves were preserved. Our initial experience with this device for nerve-sparing RPL is encouraging.
- 1 April 2004
- Published by SAGE Publications in Journal of Endourology
- Vol. 18 (3) , 273-276
Nerve-Sparing Retroperitoneal Lymphadenectomy Using Hydro-Jet Dissection: Initial Experience
Background and Purpose: Nerve-sparing retroperitoneal lymphadenectomy (RPL) is performed in a significant number of patients to preserve ejaculation after treatment for testicular cancer. Identification and preservation of the sympathetic nerves may be challenging. Hydro-Jet technology has been utilized for various surgical applications. A small high-pressure stream of water is used to delineate surgical planes, with preservation of vascular and neural structures. We have examined the utility of this technology for RPL in a porcine model and in human subjects. Materials and Method: A Helix Hydro-Jet device (Erbe, USA) was used for all procedures. A high-pressure water-jet stream is directed through a small nozzle with a 120-μm inner radius for soft-tissue dissection. The upper pressure limit (range 0-2175 psi) is set using a digital monitor. The jet is initiated using a foot pedal, and the actual pressure is monitored. A pressure of 360 to 400 psi was used for experimental studies, which was decreased to 255 to 300 psi for human use. Three pigs underwent RPL using this technique. Subsequently, RPL was performed in five men with testicular cancer, being primary in two and postchemotherapy in three. The primary diagnosis was seminoma in one and non-seminomatous cancer in four. The patient with seminoma had a residual mass after chemotherapy. Results: The procedures were completed successfully in all subjects. There were no intraoperative or postoperative complications. Hydro-Jet dissection permitted tissue selectivity, with preservation of vascular structures and sympathetic nerves. The soft tissue and lymphatics were removed with the high-pressure water stream assisted by blunt dissection. The nerve fibers were grossly resistant to the pressure used and were isolated individually. Dissection around the great vessels appeared to be safe, and no injury was observed with direct application of the jet. Lumbar arteries and veins and accessory vessels could be isolated safely. The estimated blood loss was minimal in animals and 300 to 800 mL in humans. Conclusions: Hydro-Jet dissection demonstrated tissue selectivity using a pressure range of 255 to 300 psi in humans. The vascular structures and sympathetic nerves were preserved. Our initial experience with this device for nerve-sparing RPL is encouraging.