Chunlei Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chunlei Zhao has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
Tamio Aburano
4 shared publicationsWakako Yamamoto
4 shared publicationsAtsutaka Okizaki
3 shared publicationsJunichi Sato
3 shared publicationsKenjiro Kikuchi
3 shared publicationsNoriyuki Shuke
3 shared publications
Latest Publications
- 1 July 2005
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 30 (7) , 492-495
Naturally Formed Coronary Arterial Thrombus Detected by In-111 Oxine Platelet Imaging
A 56-year-old man with acute myocardial infarction of the inferior wall was treated with thrombolytic therapy during emergency coronary angiography. Ten days later, In-111 oxine platelet imaging was performed using a hybrid single-photon emission computed tomography (SPECT)/computed tomography (CT) scanner and a continuous abnormal uptake was detected in the trunk of the right coronary artery (RCA). Thin-slice thoracic contrast-enhanced CT verified that the accumulation corresponded to the remaining thrombus in the dilated RCA. This case highlights the usefulness of In-111 oxine platelet imaging for detecting a coronary arterial thrombus. The value of hybrid SPECT/CT imaging for its correct localization is also stressed.
- 1 July 2005
- Published by Wolters Kluwer Health in Clinical Nuclear Medicine
- Vol. 30 (7) , 492-495
Naturally Formed Coronary Arterial Thrombus Detected by In-111 Oxine Platelet Imaging
A 56-year-old man with acute myocardial infarction of the inferior wall was treated with thrombolytic therapy during emergency coronary angiography. Ten days later, In-111 oxine platelet imaging was performed using a hybrid single-photon emission computed tomography (SPECT)/computed tomography (CT) scanner and a continuous abnormal uptake was detected in the trunk of the right coronary artery (RCA). Thin-slice thoracic contrast-enhanced CT verified that the accumulation corresponded to the remaining thrombus in the dilated RCA. This case highlights the usefulness of In-111 oxine platelet imaging for detecting a coronary arterial thrombus. The value of hybrid SPECT/CT imaging for its correct localization is also stressed.
- 1 May 2005
- Published by Springer Nature in Pediatric Research
- Vol. 57 (5 Part 1) , 744-748
Impaired Cardiac Sympathetic Nerve Function in Patients with Kawasaki Disease: Comparison with Myocardial Perfusion
Kawasaki disease (KD) is a leading cause of CAD in children. The impairment of cardiac sympathetic nerve function (CSNF) in the adult patients with coronary artery disease (CAD) could often be seen. However, little is known concerning the impairment of CSNF in KD patients. We investigated CSNF and its relationship with myocardial perfusion in KD patients. Eleven children with KD and 4 controls were studied with 123I-metaiodobenzylguanidine (MIBG) and stressed 201Tl single photon emission computed tomography. By the findings on coronary artery angiography (CAG), the patients were divided into 2 groups: A, without stenosis; B, with significant stenosis and/or old myocardial infarction. CSNF was evaluated from the uptake of 123I-MIBG. While myocardial perfusion was evaluated from 201Tl uptake. The numbers of patients in the groups A and B were 7 and 4. Perfusion defect was found in 0, and 2 patients in group A (0%), and B (50%). 123I-MIBG defects were found in 1 and 4 patients in the group A (14%) and B (100%). There were excellent concordances between the finding of 201Tl and 123I-MIBG in group A. While in group B, the coronary territories with 123I-MIBG defects were significantly more than those with perfusion defects (p < 0.05). In KD patients, the impairment of CSNF might be subsequent to coronary artery stenosis and was more severe than the injury of myocardial perfusion.
- 1 May 2005
- Published by Springer Nature in Pediatric Research
- Vol. 57 (5 Part 1) , 744-748
Impaired Cardiac Sympathetic Nerve Function in Patients with Kawasaki Disease: Comparison with Myocardial Perfusion
Kawasaki disease (KD) is a leading cause of CAD in children. The impairment of cardiac sympathetic nerve function (CSNF) in the adult patients with coronary artery disease (CAD) could often be seen. However, little is known concerning the impairment of CSNF in KD patients. We investigated CSNF and its relationship with myocardial perfusion in KD patients. Eleven children with KD and 4 controls were studied with 123I-metaiodobenzylguanidine (MIBG) and stressed 201Tl single photon emission computed tomography. By the findings on coronary artery angiography (CAG), the patients were divided into 2 groups: A, without stenosis; B, with significant stenosis and/or old myocardial infarction. CSNF was evaluated from the uptake of 123I-MIBG. While myocardial perfusion was evaluated from 201Tl uptake. The numbers of patients in the groups A and B were 7 and 4. Perfusion defect was found in 0, and 2 patients in group A (0%), and B (50%). 123I-MIBG defects were found in 1 and 4 patients in the group A (14%) and B (100%). There were excellent concordances between the finding of 201Tl and 123I-MIBG in group A. While in group B, the coronary territories with 123I-MIBG defects were significantly more than those with perfusion defects (p < 0.05). In KD patients, the impairment of CSNF might be subsequent to coronary artery stenosis and was more severe than the injury of myocardial perfusion.
- 1 February 2004
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 25 (2) , 159-166
Optimization of the uptake method for estimating renal clearance of 99mTc mercaptoacetyltriglycine
To improve the estimation of 99mTc mercaptoacetyltriglycine clearance in the renal uptake method by optimizing the conditions of renal depth, background, threshold for renal boundary determination, and time interval for integrating renal counts. Dynamic renal imaging was performed in 232 patients with dual energy window acquisition (main, 140±14 keV; sub, 122.5±3.5 keV). For drawing renal regions of interest (ROIs), cut-off methods with 50% and 70% of the highest renal pixel counts were used. For drawing the backgrounds, circumferential and lateral-inferior quadrant peri-renal ROIs were used. For setting the time interval, periods of 1–2, 1–2.5, 1.5–2.5, 1.5–3 and 2–3 min post-injection were used. For determining renal depth, three methods of a theoretical exponential function using scatter fraction, Tønnesen's formula, and linear combination of scatter fraction and Tønnesen's formula were used. The scatter fraction was calculated using the counts in renal ROIs in the two energy windows. Using every combination of these conditions, renal uptake was calculated. As a reference, one-sample clearance was calculated from a blood sample taken at 30 min post-injection following Bubeck's formula. According to the methods for estimating renal depth, three non-linear regression models were derived to convert renal uptake to clearance. Using one-sample clearance and integrated renal counts as dependent and independent variables, data were fitted to the models to determine the necessary constants. The correlations between the model estimated clearances and one-sample clearance were investigated. One-sample clearance ranged from 11 to 404 ml·min−1 per 1.73 m2. More than half of the regression using renal depth determined by the scatter fraction alone failed to converge. Among the successfully converged regressions, all model estimated clearances showed significant correlations (P<0.01) with one-sample clearance. The best correlation was observed in the model using renal depth determined by the combination of scatter fraction and Tønnesen's formulas, renal ROIs by 50% cut-off, lateral-inferior background and time interval of 2–3 min (r=0.898, P<0.001). The renal uptake method for estimating the clearance of mercaptoacetyltriglycine can be improved by the processing conditions proposed here.
- 1 February 2004
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 25 (2) , 159-166
Optimization of the uptake method for estimating renal clearance of 99mTc mercaptoacetyltriglycine
To improve the estimation of 99mTc mercaptoacetyltriglycine clearance in the renal uptake method by optimizing the conditions of renal depth, background, threshold for renal boundary determination, and time interval for integrating renal counts. Dynamic renal imaging was performed in 232 patients with dual energy window acquisition (main, 140±14 keV; sub, 122.5±3.5 keV). For drawing renal regions of interest (ROIs), cut-off methods with 50% and 70% of the highest renal pixel counts were used. For drawing the backgrounds, circumferential and lateral-inferior quadrant peri-renal ROIs were used. For setting the time interval, periods of 1–2, 1–2.5, 1.5–2.5, 1.5–3 and 2–3 min post-injection were used. For determining renal depth, three methods of a theoretical exponential function using scatter fraction, Tønnesen's formula, and linear combination of scatter fraction and Tønnesen's formula were used. The scatter fraction was calculated using the counts in renal ROIs in the two energy windows. Using every combination of these conditions, renal uptake was calculated. As a reference, one-sample clearance was calculated from a blood sample taken at 30 min post-injection following Bubeck's formula. According to the methods for estimating renal depth, three non-linear regression models were derived to convert renal uptake to clearance. Using one-sample clearance and integrated renal counts as dependent and independent variables, data were fitted to the models to determine the necessary constants. The correlations between the model estimated clearances and one-sample clearance were investigated. One-sample clearance ranged from 11 to 404 ml·min−1 per 1.73 m2. More than half of the regression using renal depth determined by the scatter fraction alone failed to converge. Among the successfully converged regressions, all model estimated clearances showed significant correlations (P<0.01) with one-sample clearance. The best correlation was observed in the model using renal depth determined by the combination of scatter fraction and Tønnesen's formulas, renal ROIs by 50% cut-off, lateral-inferior background and time interval of 2–3 min (r=0.898, P<0.001). The renal uptake method for estimating the clearance of mercaptoacetyltriglycine can be improved by the processing conditions proposed here.
- 1 October 2003
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 17 (7) , 541-548
Comparison of myocardial fatty acid metabolism with left ventricular function and perfusion in cardiomyopathies: by123I-BMIPP SPECT and99mTc-tetrofosmin electrocardiographically gated SPECT
Objective: To investigate myocardial fatty acid metabolism and its relationship with left ventricular (LV) function and perfusion in hypertrophic cardiomyopathy (HCM) and dilated cardiomyopathy (DCM).Methods: Thirty-nine patients with cardiomyopathies (58±14 y), comprising 15 DCM and 24 HCM, and 9 age-matched healthy controls were studied with123I-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (BMIPP) and99mTc-tetrofosmin (TF) electrocardiographically gated SPECT. As parameters of myocardial fatty acid metabolism, the heart-to-mediastinum ratio (H/M) and global washout of BMIPP were calculated from early and delayed planar images, while regional BMIPP uptake and washout were calculated from SPECT. In TF study, the H/M (H/M-TF) and LV ejection fraction (LVEF) were calculated as global parameters of perfusion and function, while regional TF uptake and wall thickening index were calculated as regional parameters of perfusion and function using the Quantitative Gated SPECT software. The differences in the parameters and the correlations between the parameters from the 2 studies were investigated by one-way ANOVA and multiple linear regression analysis.Results: BMIPP uptake was decreased (pConclusion: In DCM, BMIPP uptake and washout could not reflect LV function. In HCM, regional delayed BMIPP uptake might be useful for evaluating regional function. In DCM and HCM, early BMIPP uptake might be largely determined by myocardial perfusion.
- 1 October 2003
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 17 (7) , 541-548
Comparison of myocardial fatty acid metabolism with left ventricular function and perfusion in cardiomyopathies: by123I-BMIPP SPECT and99mTc-tetrofosmin electrocardiographically gated SPECT
Objective: To investigate myocardial fatty acid metabolism and its relationship with left ventricular (LV) function and perfusion in hypertrophic cardiomyopathy (HCM) and dilated cardiomyopathy (DCM).Methods: Thirty-nine patients with cardiomyopathies (58±14 y), comprising 15 DCM and 24 HCM, and 9 age-matched healthy controls were studied with123I-15-(p-iodophenyl)-3-(R,S)-methylpentadecanoic acid (BMIPP) and99mTc-tetrofosmin (TF) electrocardiographically gated SPECT. As parameters of myocardial fatty acid metabolism, the heart-to-mediastinum ratio (H/M) and global washout of BMIPP were calculated from early and delayed planar images, while regional BMIPP uptake and washout were calculated from SPECT. In TF study, the H/M (H/M-TF) and LV ejection fraction (LVEF) were calculated as global parameters of perfusion and function, while regional TF uptake and wall thickening index were calculated as regional parameters of perfusion and function using the Quantitative Gated SPECT software. The differences in the parameters and the correlations between the parameters from the 2 studies were investigated by one-way ANOVA and multiple linear regression analysis.Results: BMIPP uptake was decreased (pConclusion: In DCM, BMIPP uptake and washout could not reflect LV function. In HCM, regional delayed BMIPP uptake might be useful for evaluating regional function. In DCM and HCM, early BMIPP uptake might be largely determined by myocardial perfusion.