AMAhmed Maawadh

Ahmed Maawadh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ahmed Maawadh has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of different finishing and polishing systems on surface properties of universal single shade resin-based composites

    by Ghada Alharbi, Hend NA Al Nahedh, Loulwa M. Al-Saud, Nourah Shono, Ahmed Maawadh

    Background: Recently, universal single-shade resin composites have become increasingly available in the dental market. The modification of their composition can have an inadvertent effect on their physical and surface properties, and subsequently determinantal effect on their clinical function and longevity. Therefore, this study aimed to evaluate the effect of different finishing and polishing (F/P) systems on surface roughness (Ra), surface gloss (GU), and Vickers microhardness (VMH) of universal single-shade RBCs. Materials and methods: Four commercial RBCs were used; the universal single-shade RBCs were Omnichroma, Charisma® Diamond ONE, and Vittra APS Unique, and a conventional nanocomposite Filtek™ Z250 XT was used as a control. The 3 F/P systems were Sof-Lex™ XT, Enhance®/PoGo®, and Diacomp® Plus Twist. A total of 160 discs were used for the 3 F/P system groups for all RBCs (n = 10). After F/P, the Ra, GU, and VMH were assessed. The data were analyzed using 2-way ANOVA at p-value < 0.05. Results: Significant differences were found among the four RBCs and the 3 F/P systems (p < .000). Omnichroma showed the lowest Ra and acceptable GU, but the lowest VMH. Charisma showed the highest Ra, acceptable GU, and VMH. Vittra showed acceptable Ra, GU, and VMH and Filtek showed the highest GU, VMH, and acceptable Ra. Conclusion: Although conventional nanohybrid RBC (Filtek Z250 XT) showed better GU and VMH values, the universal single-shade RBCs demonstrated comparable surface properties. The highest GU & VMH and lowest Ra were achieved by Diacomp followed by Enhance and Soflex.


  • Open Access

    Use of Reparative Agents Topical Fluoride Activated by CO2 Laser and Curodontâ„¢ Repair and NR-5â„¢ on Vickers Hardness and Micro-Shear Bond Strength of Eroded Enamel to Composite Restoration

    by K. Alahdal, T. Almohareb, Laila Aldeeb, A. Maawadh, A. S. Alshamrani, A. Alrahlah

    Aim: This study aims to assess the impact of various reparative remineralizing agents, specifically topical fluoride (TF) and a combination of a carbon dioxide laser (CO2 laser) with TF, as well as regenerative agents such as Curodont™ Repair and NR-5™, on two key factors—the micro-Vickers hardness (VH) of eroded enamel and the micro-shear bond strength (µSBS) of composite restoration. Materials and Methods: A total of 50 single-rooted premolars with intact enamel were sectioned mesiodistally into two halves, making a sample size of 100 specimens. All of the samples were then exposed to Coca-ColaTM for 2 min each day over 1 month to induce erosion on the enamel surface. The specimens were then embedded in acrylic cold-cure resin facing a flat surface upward. The samples were then arbitrarily divided into five groups based on the remineralizing and regenerative agents used, as follows (n = 20): Group 1: No remineralizing agent, Group 2: Curodont™ Repair, Group 3: NR-5™, Group 4: TF, and Group 5: CO2 laser + TF. The VH of the pretreated enamel surfaces was analyzed and µSBS testing and failure mode of composite restoration were performed using a universal testing machine (UTM) and stereomicroscope. ANOVA and Tukey’s post hoc were performed for data analysis. Results: In Group 3, the (NR-5™)-treated teeth exhibited the highest VH values and µSBS. In Group 1, the (No remineralizing agent)-treated specimens displayed the lowest VH and the lowest µSBS. An intergroup comparison analysis unveiled that Group 3, Group 4 (TF), and Group 5 (CO2 laser + TF) presented comparable outcomes of microhardness and bond strength. The Group 2 (Curodont™ Repair) samples exhibited no significant difference in VH and µSBS, as compared to Group 1. Conclusions: The use of a combination of NR-5™ technology and a CO2 laser in conjunction with TF has been shown to significantly augment the natural mineralization process. This enhancement results in increased microhardness and an improved bond strength in the treated enamel.


  • Open Access

    Different Designs of Deep Marginal Elevation and Its Influence on Fracture Resistance of Teeth with Monolith Zirconia Full-Contour Crowns

    by Ali Robaian, Abdullah Alqahtani, Khalid Alanazi, Abdulrhman Alanazi, Meshal Almalki, Anas Aljarad, Refal Albaijan, Ahmed Maawadh, Aref Sufyan, Mubashir Baig Mirza

    Background and objectives: Even with the demand for high esthetics, the strength of the material for esthetic applications continues to be important. In this study, monolith zirconia (MZi) crowns fabricated using CAD/CAM were tested for fracture resistance (FR) in teeth with class II cavity designs with varying proximal depths, restored through a deep marginal elevation technique (DME). Materials and Methods: Forty premolars were randomly divided into four groups of ten teeth. In Group A, tooth preparation was conducted and MZi crowns were fabricated. In Group B, mesio-occluso-distal (MOD) cavities were prepared and restored with microhybrid composites before tooth preparation and the fabrication of MZi crowns. In Groups C and D, MOD cavities were prepared, differentiated by the depth of the gingival seat, 2 mm and 4 mm below the cemento-enamel junction (CEJ). Microhybrid composite resin was used for DME on the CEJ and for the restoration of the MOD cavities; beforehand, tooth preparations were conducted and MZi crowns were and cemented using resin cement. The maximum load to fracture (in newtons (N)) and FR (in megapascals (MPa)) were measured using the universal testing machine. Results: The average scores indicate a gradual decrease in the load required to fracture the samples from Groups A to D, with mean values of 3415.61 N, 2494.11 N, 2108.25 N and 1891.95 N, respectively. ANOVA revealed highly significant differences between the groups. Multiple group comparisons using the Tukey HSD post hoc test revealed that Group D had greater DME depths and showed significant differences compared with Group B. Conclusions: FR in teeth decreased when more tooth structure was involved, even with MZi crowns. However, DME up to 2 mm below the CEJ did not negatively influence the FR. Strengthening the DME-treated teeth with MZi crowns could be a reasonable clinical option, as the force required to fracture the samples far exceeded the maximum recorded biting force for posterior teeth.


  • Open Access

    Color Change, Biaxial Flexural Strength, and Fractographic Analysis of Resin-Modified CAD/CAM Ceramics Subjected to Different Surface Finishing Protocols

    by Mona Alhassan, Ahmed Maawadh, Nawaf Labban, Nourah Shono, Ahmad Alebdi, Saleh Alhijji, Abdulelah M. BinMahfooz

    This in vitro study compared the color change (∆E) and biaxial flexural strength (BFS) of two resin nanoceramics (LU and CS) and two polymer-infiltrated ceramic networks (VE and CU) after different surface finishing protocols. A total of 192 discs (12 × 1.2 mm2) were prepared from the materials (n = 48) and then polished with 1200-grit silicon carbide paper, followed by roughening with a 30 µm grit diamond bur. According to the surface finishing applied, the discs from each material category were categorized into four groups: control group (no finishing), polishing (MP), glazing (OG), or a combination of MP and additional polishing (MP+PP). Following surface finishing, all the discs were immersed in a coffee beverage to simulate one year of clinical use. A spectrophotometer and universal testing machine were used to measure the ∆E and BFS, respectively. Fractographic analysis was performed using scanning electron microscopy images. Multivariate analysis of variance was used for the statistical analysis, followed by one-way ANOVA and post hoc Dunnett’s test (a = 0.05). The ∆E and BFS were significantly impacted by material type and surface finishing (p ≤ 0.05). Irrespective of the materials and finishing, untreated LU and OG-treated VE specimens demonstrated the highest (2.98 ± 0.36) and lowest (1.21 ± 0.33) color changes. Regarding BFS, untreated CU and OG-treated CS specimens demonstrated the lowest (121.88 ± 2.08 MPa) and highest (174.17 ± 3.83 MPa) values. Surface finishing using glazing resulted in the highest BFS and lowest ∆E compared to other surface finishing protocols for the tested materials. VE demonstrated the least color changes, and CS showed the highest BFS following surface finishing of the materials tested. Surface finishing is material dependent; thus, it is critical to use the best surface finishing protocol in a clinical setting.


  • Open Access

    Effect of Different Surface Treatments on the Surface Roughness and Gloss of Resin-Modified CAD/CAM Ceramics

    by Mona Alhassan, Ahmed Maawadh, Nawaf Labban, Sarah M. Alnafaiy, Hanan N. Alotaibi, Abdulelah M. BinMahfooz

    The purpose of this in vitro study is to compare the roughness and gloss of four resin-modified CAD/CAM ceramics after different surface treatments. Forty-eight specimens (1.20 × 12 mm2) were prepared from Lava Ultimate (LU), Vita Enamic (VE), Cerasmart (CS), and Crystal Ultra (CU) CAD/CAM ceramics. The prepared specimens were polished with silicon carbide paper before being roughened with a 30 µm grit diamond bur. Each material was allocated into four groups: control (no treatment), Luster Meisinger polishing (MP), Optiglaze (OG), or Meisinger polishing, followed by a final polishing with Shofu Direct Dia Paste (MP+PP). The roughness and gloss were measured after the surface treatment using a profilometer and gloss meter, respectively. Scanning electron microscopy micrographs were obtained to analyze the surface characteristics. Statistical analysis was performed using a multivariate analysis of variance (MANOVA), one-way ANOVA, and Dunnett’s post hoc test (α = 0.05). The surface treatments significantly affected the surface roughness and gloss of the tested materials (p < 0.05). All the tested resin-modified CAD/CAM ceramics demonstrated a lower surface roughness and higher gloss after glazing using OG, followed by MP+PP and MP. The highest and lowest Ra were presented by the control VE (0.63 ± 0.23 µm) and glazed LU specimens (0.04 ± 0.01 µm), respectively. The highest and lowest GU were presented by the glazed LU (90.48 ± 4.69 GU) and the control VE specimens (23.32 ± 2.41 GU), respectively. After clinical adjustment, finishing, and polishing, the restoration is essential to obtain a restorative surface with lower roughness and the highest gloss. Surface glazing using Optiglaze exhibited the smoothest and glossiest surface of all the tested resin-modified ceramics.


  • Open Access

    Influence of Acidic Environment on the Hardness, Surface Roughness and Wear Ability of CAD/CAM Resin-Matrix Ceramics

    by Wejdan S. Alghamdi, Nawaf Labban, Ahmed Maawadh, Hussain D. Alsayed, Huda Alshehri, Ali Alrahlah, Sarah M. Alnafaiy

    This study aimed to measure the effect of storage environment on the hardness, surface roughness and wear ability of CAD/CAM resin-matrix ceramics. A total of 200 rectangular-shaped specimens were obtained by sectioning 5 CAD/CAM blocks; Crystal Ultra (CU), Vita Enamic (VE), Lava Ultimate (LU), Cerasmart (CS) and Vita blocks Mark II (MII). Microhardness and surface roughness were measured at baseline and after 7 days of immersion either in saliva or cola (n = 10). The wear ability of the CAD/CAM materials against steatite-ceramics antagonist was determined using a chewing simulator. The data were statistically analyzed using factorial ANOVA followed by post hoc Bonferroni multiple comparison tests (p < 0.05). The independent factors significantly influenced the microhardness and surface roughness (p < 0.05). The highest VHN was observed in MII at baseline (586.97 ± 13.95), while CU showed the lowest VHN after 7 days of immersion in cola (68.3 ± 1.89). On the contrary, the highest Ra was observed after 120,000 chewing cycles for the VE specimens (1.09 ± 0.43 µm) immersed in cola, while LU showed the lowest Ra at baseline (0.07 ± 0.01 µm). The highest % mass loss of the antagonist was observed with MII immersed in cola (1.801%), while CS demonstrated the lowest % mass loss of 0.004% and 0.007% in AS and cola, respectively. This study confirms that the surface properties of tested CAD/CAM materials are susceptible to degradation in an acidic environment except for hardness and wear of CS material.


  • Effect of Translucency and Curing Mode of Four CAD/CAM Materials on Polymerization Efficiency of Light and Dual Cure Resin Cements

    by N N Shono, A Elhejazi, A Maawadh, H Al Nahedh

    To determine the effect of translucency of four CAD/CAM materials and different curing modes on the degree of conversion of resin cements. Disks were fabricated from IPS e.max CAD, Vita Suprinity, Vita Enamic, and DD Cube X². Translucency was measured using a spectrophotometer. The degree of conversion of two resin cements Variolink Esthetic DC and LC were measured using a Fourier transform infrared spectrometer. For Esthetic DC, the degree of conversion was determined in self-cure and dual cure modes. ANOVA, Tukey HSD test, and /Linear Regression R2 were used to statistically analyze the data. There was a significant difference in the translucency of the four materials (P ⟨ 0.0001). The mean translucency of Vita Suprinity was significantly higher, followed by Vita Enamic, DD Cube X², and IPS E.max CAD. Degree of conversion of resin cements cured under DD Cube X² had the highest values (25.22%), whereas those cured under Vita Suprinity showed the lowest values (17.86%). The self-cure mode had the lowest degree of conversion values (16.22%) and dual cure mode showed the highest values (26.12%). A negative linear relationship was found between degree of conversion and translucency of the CAD/CAM materials.


  • Open Access

    Correction: Alnafaiy et al. Repair Bond Strength of Composite Resin to Aged Resin and Glass-Matrix CAD/CAM Ceramic Materials Using Two Different Repair Systems. Coatings 2021, 11, 1331

    by Sarah Alnafaiy, Nawaf Labban, Ahmed Maawadh, Huda Alshehri, Refal Albaijan

    The authors wishe to make the following corrections to this paper