Huoliang Kong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Huoliang Kong has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Huifang Wu
College of Environment, Nanjing University of Technology, Nanjing, Jiangsu, China
2 shared publications- Juan Liu
Institute of Organic Contaminant Control and Soil Remediation, College of Resources and Environmental Sciences, Nanjing Agricultural University, Nanjing 210095, PR China
1 shared publication - Yanzheng Gao
Institute of Organic Contaminant Control and Soil Remediation, College of Resources and Environmental Sciences, Nanjing Agricultural University, Weigang Road 1, Nanjing 210095, P.R. China
1 shared publication - Yi Zhang
Nanjing Agricultural University
1 shared publication
Latest Publications
- 27 July 2012
- Published by Springer Nature in Plant and Soil
- Vol. 365 (1-2) , 171-182
Metabolism and subcellular distribution of anthracene in tall fescue (Festuca arundinacea Schreb.)
- 27 July 2012
- Published by Springer Nature in Plant and Soil
- Vol. 365 (1-2) , 171-182
Metabolism and subcellular distribution of anthracene in tall fescue (Festuca arundinacea Schreb.)
- 1 November 2009
- Published by Wiley in Water Environment Research
- Vol. 81 (11) , 2381-2386
A Rapid Determination Method of Chemical Oxygen Demand in Printing and Dyeing Wastewater Using Ultraviolet Spectroscopy
A rapid method to determine chemical oxygen demand (COD) in printing and dyeing wastewater using ultraviolet (UV) spectroscopy was developed in this study. The UV method has several advantages compared to the chemical method, such as shortened analysis time, convenience, no requirement of expensive and toxic reagents, and good reproducibility. It was established that the magnitude of COD and, to a certain extent, pH and suspended solids of the sample have effects on the accuracy and precision of the method. The results showed the fitting range of CODCr (COD determined by the dichromate method) was 0 to 360 mg/L−1 And the pH ranged from 2.45 to 9.22. If the UV365 (UV absorbance at 365 nm) is measured and is subtracted from UV254 (UV absorbance at 254 nm), then the effects of suspended solids was eliminated. A control experiment of CODCr determination using the rapid method and the standard dichromate method was carried out, which validated the former.
- 1 November 2009
- Published by Wiley in Water Environment Research
- Vol. 81 (11) , 2381-2386
A Rapid Determination Method of Chemical Oxygen Demand in Printing and Dyeing Wastewater Using Ultraviolet Spectroscopy
A rapid method to determine chemical oxygen demand (COD) in printing and dyeing wastewater using ultraviolet (UV) spectroscopy was developed in this study. The UV method has several advantages compared to the chemical method, such as shortened analysis time, convenience, no requirement of expensive and toxic reagents, and good reproducibility. It was established that the magnitude of COD and, to a certain extent, pH and suspended solids of the sample have effects on the accuracy and precision of the method. The results showed the fitting range of CODCr (COD determined by the dichromate method) was 0 to 360 mg/L−1 And the pH ranged from 2.45 to 9.22. If the UV365 (UV absorbance at 365 nm) is measured and is subtracted from UV254 (UV absorbance at 254 nm), then the effects of suspended solids was eliminated. A control experiment of CODCr determination using the rapid method and the standard dichromate method was carried out, which validated the former.
- 1 November 2008
- Published by Elsevier in Bioresource Technology
- Vol. 99 (16) , 7886-7891
Pretreatment of textile dyeing wastewater using an anoxic baffled reactor
- 1 November 2008
- Published by Elsevier in Bioresource Technology
- Vol. 99 (16) , 7886-7891