BJBongim Jun

Bongim Jun

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bongim Jun has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Flight photon counting electron multiplying charge coupled device development for the Roman Space Telescope coronagraph instrument

    by Patrick Morrissey, Leon K. Harding, Nathan L. Bush, Michael Bottom, Bijan Nemati, Andrew Daniel, Bongim Jun, Luz Maria Sierra Martinez, Niyati Desai, Dave Barry, et al.

    The NASA Jet Propulsion Laboratory (JPL) is developing a coronagraph instrument (CGI) for the 2.4 m Nancy Grace Roman Space Telescope, expected to launch in the mid-2020s. The CGI will demonstrate technologies needed for direct imaging and spectroscopy of exoplanets.1 To meet the challenges of detecting the faint planet signal, JPL selected the electron multiplying charge coupled device (EMCCD) from Teledyne-e2v (Chelmsford, United Kingdom) as part of a previous study.2 To streamline the instrument development, a single camera design serves two broadly different applications. The two cameras are arranged on each side of a coronagraph mask that is used to reject the core of bright light from the stellar target while admitting the nearby field containing possible planetary orbits. A science camera downstream of the mask called ExCam (the exoplanetary systems camera) is used to acquire stars, to provide feedback to the adaptive optical system required to reduce diffracted light close to a stellar image, and to collect the remaining faint light from target objects in the field. The second camera upstream of the mask is used for high-speed pointing. This camera, called LoCam (the low order wavefront sensing camera), collects the bright rejected starlight from the coronagraph reimaged as a pupil in a 50×50  pixel region that is read out at 1000  frames-s−1. Both cameras are required to read out at high speed (although not at high frame rate) to support shutterless operation, and to operate over a wide range of intensity (∼108x for ExCam).


  • Intercomparison of Ionizing Doses From Space Shielding Analyses Using MCNP, Geant4, FASTRAD, and NOVICE

    by Bongim Jun, Brian Xiaoyu Zhu, Luz Maria Martinez-Sierra, Insoo Jun

    Several commonly-used space radiation particle transport tools, MCNP, Geant4, FASTRAD, and NOVICE are compared to check consistency of total ionizing dose (TID) estimates for hardware in a harsh-electron Jovian mission environment. Simple geometries with aluminum, tantalum, and a combination of both materials were used to represent typical and high density shields. The forward Monte Carlo (FMC) analyses from MCNP and Geant4 were in a good agreement within run uncertainty. Compared to FMC results, the reverse Monte Carlo (RMC) analysis results from NOVICE and FASTRAD differed by ±20% ~ ±50%, depending on the simple geometrys’ material. The doses from FASTRAD’s ray-tracing methods differed from NOVICE RMC doses by +60% / –10%. TID analyses of complex as-designed geometries from selected flight instruments and electronics boxes were also compared using the NOVICE and FASTRAD tools. The TID results from these complex geometries with aluminum equivalent thickness ranging from 0.1 mil to 3000 mil (3 inches) differed by as much as +200% / –50% between FASTRAD (ray-tracing and RMC) and NOVICE analyses. We conclude that while MCNP and Geant4 FMC analysis results have extensive experimental validation and therefore provide the most accurate TID estimates, RMC analyses are faster to implement and suitable as conservative tools for missions with a sufficient mass margin. We also conclude that ray-tracing analyses can be suitable during the development phase of shield design optimization for its fast runtime capability.