Samuel Edwin Fineberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Samuel Edwin Fineberg has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Deborah Finco-Kent
Pfizer Global Research and Development, Groton, Connecticut 06320
2 shared publicationsAlan Krasner
Indiana University School of Medicine (S.E.F.), Indianapolis, Indiana 46202; and Pfizer Global Research and Development (T.K., D.F.-K., C.L., A.K.), Groton, Connecticut 06320
1 shared publicationAlan S. Krasner
Pfizer Global Research and Development, Groton, Connecticut 06320
1 shared publicationCameron Liu
Indiana University School of Medicine (S.E.F.), Indianapolis, Indiana 46202; and Pfizer Global Research and Development (T.K., D.F.-K., C.L., A.K.), Groton, Connecticut 06320
1 shared publicationGregory L. Finch
Pfizer Global Research and Development, Groton, Connecticut 06320
1 shared publicationLori M. Laffel
Joslin Diabetes Center, Boston, Massachusetts
1 shared publication
Latest Publications
- 1 October 2007
- Published by The Endocrine Society in Endocrine Reviews
- Vol. 28 (6) , 625-652
Immunological Responses to Exogenous Insulin
Regardless of purity and origin, therapeutic insulins continue to be immunogenic in humans. However, severe immunological complications occur rarely, and less severe events affect a small minority of patients. Insulin autoantibodies (IAAs) may be detectable in insulin-naive individuals who have a high likelihood of developing type 1 diabetes or in patients who have had viral disorders, have been treated with various drugs, or have autoimmune disorders or paraneoplastic syndromes. This suggests that under certain circumstances, immune tolerance to insulin can be overcome. Factors that can lead to more or less susceptibility to humoral responses to exogenous insulin include the recipient's immune response genes, age, the presence of sufficient circulating autologous insulin, and the site of insulin delivery. Little proof exists, however, that the development of insulin antibodies (IAs) to exogenous insulin therapy affects integrated glucose control, insulin dose requirements, and incidence of hypoglycemia, or contributes to beta-cell failure or to long-term complications of diabetes. Studies in which pregnant women with diabetes were monitored for glycemic control argue against a connection between IAs and fetal risk. Although studies have shown increased levels of immune complexes in patients with diabetic microangiopathic complications, these immune complexes often do not contain insulin or IAs, and insulin administration does not contribute to their formation. The majority of studies have shown no relationship between IAs and diabetic angiopathic complications, including nephropathy, retinopathy, and neuropathy. With the advent of novel insulin formulations and delivery systems, such as insulin pumps and inhaled insulin, examination of these issues is increasingly relevant.
- 1 October 2007
- Published by The Endocrine Society in Endocrine Reviews
- Vol. 28 (6) , 625-652
Immunological Responses to Exogenous Insulin
Regardless of purity and origin, therapeutic insulins continue to be immunogenic in humans. However, severe immunological complications occur rarely, and less severe events affect a small minority of patients. Insulin autoantibodies (IAAs) may be detectable in insulin-naive individuals who have a high likelihood of developing type 1 diabetes or in patients who have had viral disorders, have been treated with various drugs, or have autoimmune disorders or paraneoplastic syndromes. This suggests that under certain circumstances, immune tolerance to insulin can be overcome. Factors that can lead to more or less susceptibility to humoral responses to exogenous insulin include the recipient's immune response genes, age, the presence of sufficient circulating autologous insulin, and the site of insulin delivery. Little proof exists, however, that the development of insulin antibodies (IAs) to exogenous insulin therapy affects integrated glucose control, insulin dose requirements, and incidence of hypoglycemia, or contributes to beta-cell failure or to long-term complications of diabetes. Studies in which pregnant women with diabetes were monitored for glycemic control argue against a connection between IAs and fetal risk. Although studies have shown increased levels of immune complexes in patients with diabetic microangiopathic complications, these immune complexes often do not contain insulin or IAs, and insulin administration does not contribute to their formation. The majority of studies have shown no relationship between IAs and diabetic angiopathic complications, including nephropathy, retinopathy, and neuropathy. With the advent of novel insulin formulations and delivery systems, such as insulin pumps and inhaled insulin, examination of these issues is increasingly relevant.
- 21 June 2006
- Published by Taylor & Francis in Expert Opinion on Investigational Drugs
- Vol. 15 (7) , 743-762
Diabetes therapy trials with inhaled insulin
Administration of insulin by inhalation was first attempted > 50 years ago. At that time, little was known concerning effective delivery systems and insulin formulations. The recent development of pulmonary delivery systems for the administration of insulin is driven by the reluctance of patients and their providers to initiate insulin earlier in the course of Type 2 diabetes, the desire to reduce the number of daily insulin injections for both Type 1 and 2 patients, and the recent emphasis on intensified glycaemic control including postprandial glycaemic control. The deep lung is a unique mucosal tissue having a surface area of > 100 m2 and is readily accessible both to the external environment and to drug delivery, provided that appropriate conditions are met. There have been four mid- to late-phase pulmonary insulin programmes using modern inhalation devices that will be reported in this paper. The programmes differ in the choice of delivery systems, the formulations of insulin and reported bioavailabi...
- 21 June 2006
- Published by Taylor & Francis in Expert Opinion on Investigational Drugs
- Vol. 15 (7) , 743-762
Diabetes therapy trials with inhaled insulin
Administration of insulin by inhalation was first attempted > 50 years ago. At that time, little was known concerning effective delivery systems and insulin formulations. The recent development of pulmonary delivery systems for the administration of insulin is driven by the reluctance of patients and their providers to initiate insulin earlier in the course of Type 2 diabetes, the desire to reduce the number of daily insulin injections for both Type 1 and 2 patients, and the recent emphasis on intensified glycaemic control including postprandial glycaemic control. The deep lung is a unique mucosal tissue having a surface area of > 100 m2 and is readily accessible both to the external environment and to drug delivery, provided that appropriate conditions are met. There have been four mid- to late-phase pulmonary insulin programmes using modern inhalation devices that will be reported in this paper. The programmes differ in the choice of delivery systems, the formulations of insulin and reported bioavailabi...
- 1 June 2005
- Published by The Endocrine Society in The Journal of Clinical Endocrinology & Metabolism
- Vol. 90 (6) , 3287-3294
Antibody Response to Inhaled Insulin in Patients with Type 1 or Type 2 Diabetes. An Analysis of Initial Phase II and III Inhaled Insulin (Exubera) Trials and a Two-Year Extension Trial
Objective: To compare antibody responses to inhaled human insulin vs. sc human insulin and to determine whether insulin antibody binding is associated with adverse clinical consequences. Research Design and Methods: Insulin antibody data from initial phase II/III trials were analyzed comparing the efficacy and safety of inhaled insulin with various agents, including sc insulin. Additionally, data from a 24-month extension of the phase III studies were examined. Data were pooled into the following three groups based on insulin treatment status at baseline: patients with type 1 diabetes, and patients with type 2 diabetes using insulin and not using insulin at baseline. Ig class analysis was also performed on randomly selected sera from type 1 patients at the end of the initial trials. Results: In the initial trials, greater insulin antibody binding was observed in patients receiving inhaled insulin vs. sc insulin. The greatest antibody responses to inhaled insulin were observed in patients with type 1 diabetes [nonparametric comparison of medians at the end of the study, 22.0% binding (unadjusted 95% confidence interval: 19.5, 24.5)], and the lowest responses were observed in non-insulin-using patients with type 2 diabetes in which there was no difference in median values at the end of the study. There were no correlations between antibody binding and glycemic control (measured using glycosylated hemoglobin), insulin dose requirements, hypoglycemic events, or pulmonary function (measured by changes in forced expiratory volume in 1 sec and diffusion capacity of carbon monoxide). Antibody responses were IgG in type. Differences in antibody levels observed in patients with type 1 vs. type 2 diabetes were maintained over the 24-month extension trials. Peak antibody levels across all groups were generally observed after 6–12 months of insulin therapy. Inhaled insulin therapy was not associated with a greater incidence of allergy or other hypersensitivity reactions. Conclusion: Inhaled insulin was observed to produce a larger antibody response than sc insulin. Insulin antibody binding has not been associated with adverse clinical consequences in trials to date.
- 1 June 2005
- Published by The Endocrine Society in The Journal of Clinical Endocrinology & Metabolism
- Vol. 90 (6) , 3287-3294
Antibody Response to Inhaled Insulin in Patients with Type 1 or Type 2 Diabetes. An Analysis of Initial Phase II and III Inhaled Insulin (Exubera) Trials and a Two-Year Extension Trial
Objective: To compare antibody responses to inhaled human insulin vs. sc human insulin and to determine whether insulin antibody binding is associated with adverse clinical consequences. Research Design and Methods: Insulin antibody data from initial phase II/III trials were analyzed comparing the efficacy and safety of inhaled insulin with various agents, including sc insulin. Additionally, data from a 24-month extension of the phase III studies were examined. Data were pooled into the following three groups based on insulin treatment status at baseline: patients with type 1 diabetes, and patients with type 2 diabetes using insulin and not using insulin at baseline. Ig class analysis was also performed on randomly selected sera from type 1 patients at the end of the initial trials. Results: In the initial trials, greater insulin antibody binding was observed in patients receiving inhaled insulin vs. sc insulin. The greatest antibody responses to inhaled insulin were observed in patients with type 1 diabetes [nonparametric comparison of medians at the end of the study, 22.0% binding (unadjusted 95% confidence interval: 19.5, 24.5)], and the lowest responses were observed in non-insulin-using patients with type 2 diabetes in which there was no difference in median values at the end of the study. There were no correlations between antibody binding and glycemic control (measured using glycosylated hemoglobin), insulin dose requirements, hypoglycemic events, or pulmonary function (measured by changes in forced expiratory volume in 1 sec and diffusion capacity of carbon monoxide). Antibody responses were IgG in type. Differences in antibody levels observed in patients with type 1 vs. type 2 diabetes were maintained over the 24-month extension trials. Peak antibody levels across all groups were generally observed after 6–12 months of insulin therapy. Inhaled insulin therapy was not associated with a greater incidence of allergy or other hypersensitivity reactions. Conclusion: Inhaled insulin was observed to produce a larger antibody response than sc insulin. Insulin antibody binding has not been associated with adverse clinical consequences in trials to date.
- Open Access
- 1 July 2001
- Published by American Diabetes Association in Diabetes Care
- Vol. 24 (7) , 1217-1220
Use of an Automated Device for Alternative Site Blood Glucose Monitoring
OBJECTIVE—To evaluate the accuracy, comfort, and ease of use of a new automated device for blood glucose monitoring using the arm as an alternative sampling site. RESEARCH DESIGN AND METHODS—These studies use an automated hand-held device that applies a small vacuum, lances the skin, transfers blood onto an electrochemical test strip, and measures glucose. Patients who had type 1 or type 2 diabetes and had received no prior training using this device were recruited from five diabetes clinics. Testing was performed by the patients using this device and by trained healthcare professionals. Blood glucose was measured by 354 patients: from the arm using the device, from the finger using a laboratory reference instrument, and from the finger using the device via the secondary test port. Each patient completed a questionnaire rating the level of pain and ease of use of the device. RESULTS—Blood glucose results in samples obtained from the arm with the automated device agreed well with finger-stick plasma glucose results using a reference instrument (regression slope 0.98, intercept 0.01 mmol/l [0.1 mg/dl], r = 0.96). Error grid analysis showed that 100% of the measurements fell within zones A and B. In the survey, 60% of the patients reported that arm testing with the automated device was “painless;” another 31% of the patients stated that it was “much less painful,” and 6% of patients considered using the device “less painful” than finger-stick testing. In a survey containing 15 questions for rating the ease of use with a scale of 1 to 6, the overall mean rating was 5.5. CONCLUSIONS—The automated device is easy to use and provides accurate glucose results; 97% of the patients found it less painful than finger-stick testing.
- 1 July 2001
- Published by American Diabetes Association in Diabetes Care
- Vol. 24 (7) , 1217-1220
Open AccessUse of an Automated Device for Alternative Site Blood Glucose Monitoring
OBJECTIVE—To evaluate the accuracy, comfort, and ease of use of a new automated device for blood glucose monitoring using the arm as an alternative sampling site. RESEARCH DESIGN AND METHODS—These studies use an automated hand-held device that applies a small vacuum, lances the skin, transfers blood onto an electrochemical test strip, and measures glucose. Patients who had type 1 or type 2 diabetes and had received no prior training using this device were recruited from five diabetes clinics. Testing was performed by the patients using this device and by trained healthcare professionals. Blood glucose was measured by 354 patients: from the arm using the device, from the finger using a laboratory reference instrument, and from the finger using the device via the secondary test port. Each patient completed a questionnaire rating the level of pain and ease of use of the device. RESULTS—Blood glucose results in samples obtained from the arm with the automated device agreed well with finger-stick plasma glucose results using a reference instrument (regression slope 0.98, intercept 0.01 mmol/l [0.1 mg/dl], r = 0.96). Error grid analysis showed that 100% of the measurements fell within zones A and B. In the survey, 60% of the patients reported that arm testing with the automated device was “painless;” another 31% of the patients stated that it was “much less painful,” and 6% of patients considered using the device “less painful” than finger-stick testing. In a survey containing 15 questions for rating the ease of use with a scale of 1 to 6, the overall mean rating was 5.5. CONCLUSIONS—The automated device is easy to use and provides accurate glucose results; 97% of the patients found it less painful than finger-stick testing.
- 1 December 2000
- Published by Springer Nature in Drugs & Aging
- Vol. 17 (6) , 453-461
Glycaemic Control and Hormone Replacement Therapy
- 1 December 2000
- Published by Springer Nature in Drugs & Aging
- Vol. 17 (6) , 453-461
Glycaemic Control and Hormone Replacement Therapy