Latest Publications

  • Open Access

    Distributed Load Shedding considering the Multicriteria Decision-Making Based on the Application of the Analytic Hierarchy Process

    by Nghia T. Le, An T. Nguyen, Thi Trang Hoang, Hoang Minh Vu Nguyen, Anh H. Quyen, Binh T. T. Phan

    This paper shows an analytic hierarchy process (AHP) algorithm-based approach for load shedding based on the coordination of the load importance factor (LIF), the reciprocal phase angle sensitivity (RPAS), and the voltage electrical distance (VED) to rank the load buses. This problem is important from a power system point of view, and the AHP method is able to support the decision-making process in a simple and intuitive way in a three-criterion environment. This satisfies the multicriteria decision-making to meet economic-technical aspects. The ranking and distributed shedding power at each demand load bus are based on this combined weight. The smaller overall weights of the load buses show the lesser importance of the load bus, the smaller reciprocal phase angle sensitivity, and the closer voltage electrical distance. Therefore, these load buses cut a larger amount of capacity, and vice versa. By considering the generator control, the load shedding consists of the primary and secondary control features of the generators to minimize the load shedding capacity and restore the system frequency value back to the allowable range. The efficiency of the suggested load-shedding scheme was verified via the comparison with the under-frequency load shedding (UFLS). The latter result is that the load shedding power of the suggested approach is 22.64% lower than the UFLS method. The case studies are experienced on the IEEE 9-generator; the 37-bus system has proven its effectiveness.


  • Load Shedding in Islanded Microgrid with Uncertain Conditions

    by Thi Thanh Binh Phan, Quoc Dung Phan, L. Tran, Q. Vo, T. Vu, H. Nguyen, Trong Nghia Le


  • Open Access

    Optimal Generator Dispatching With Uncertain Conditions for Islanded Microgrid

    by Thi Thanh Binh Phan, Trong Nghia Le, Quoc Dung Phan, Khang Nguyen

    This paper proposes the models to solve the optimal generator dispatching problem in an islanded Micro grid with different uncertainties in the constraint and in the objective coefficient. The optimal problem with interval in the power balance constraint is considered as a linear parametric optimization problem, focusing on optimal solutions based on the lower and upper ends of this interval. When the coefficients of cost per power unit caused by load shedding are imprecise and expressed as intervals, the proposed model will be based on the two ends of interval and the problem is converted to a two-objective problem. With uncertainties in both constraint and objective coefficient, the problem will be treated as a four-objective one, considering the lower and upper ends of all intervals. All models are expressed in the linear forms and the linearization is carried out by Max-Affine method. To solve this multi-objective problem, the Bellman-Zadeh approach and Particle Swarm Optimization (PSO) algorithm are applied. The rationality of the proposed models is confirmed in the case study with one low voltage Micro Grid.


  • Open Access

    The optimal generator dispatching with uncertain conditions for grid-connected microgrid

    by Phan Quoc Dung, Phan Thi Thanh Binh, Pham Dinh Minh, Tran Minh Hung, Nguyen Duc Hung

    Nowadays, the penetration of wind and solar sources is relatively high in Micro Grid. Wind speed and solar radiation forecasting hardly gives an exact value and leads to the values in intervals. Therefore forecasted output powers of these sources are also in the intervals. The constraint on power balance in Micro Grid has the right-hand-side uncertainty, in the interval. So for Micro-Grid in grid connection mode, the presence of the distributed generations based on wind and solar energy sources makes optimal dispatching problems of distributed generations become an uncertainty problem. The optimal solutions for the lower and upper ends of this interval are the best and the worst optimal solution. This paper proposes to treat the above problem as the optimal problem with two objectives: reach the best and the worst solution. The principle of fuzzy set and the Particle Swarm Optimization algorithm will be applied for solving the multi-objective problem. The final optimal value will belong to an interval. Meanwhile, the output power of the swing generator varies to respond to the uncertainty of wind and solar source power. An example of a low-voltage MG with three distributed generators is considered with two cases: connecting to the utility grid via the circuit breaker and via power controller.

  • Open Access

    Energy management of Micro grid in the island mode

    by Phan Thi Thanh Binh, Nguyen Tri Dung, Vo Viet Cuong

    The power management in micro grid (MG) is related to the planning of dispatchable sources such as diesel generator or storage devices due to the fluctuation of output power of renewable sources like wind and solar. In the island mode, to balance the power in the case of output changing from wind and solar sources, the control trategy such as regulating the power of dispatchable generators and load shedding is necessary. This paper introduced the way to determine the load amount be shed for N ahead moment, based on conflict multi objectives, applying the Particle Swarm optimization algorithm and Belman-Zadeh principle to find out the strategy of generating the power in MG. The application for one medium voltage MG is also presented.

  • Data Reduction for Dynamic Stability Classification in Power System

    by Ngoc Au Nguyen, Trong Nghia Le, Huy Anh Quyen, Thi Thanh Binh Phan

    A large oscillation of power system caused by faults must be quickly treated so that the opportunity driving power system into re-stability state can be easier. Necessity is to select a compact data-set that is the representative of all data-sets with the aim of reducing computing costs, reducing computer memory, and improving classification accuracy. The K-means (KM) algorithm is the most commonly used clustering algorithm because it can be easily implemented and is the most effective one in terms of the execution time on large data size. The key problem of KM is that it is sensitive to initial center and may converge to a local optimization. In this paper, we proposed the use of Hybrid K-means (HKM) data clustering algorithm that can avoid being trapped in a local optimal solution. The HKM was applied with the aim of reducing data space. We also proposed a process data clustering applied to classify the problem of dynamic stability in power system. The K-Nearest Neighbor (K-NN) was chosen as the classifier. The K-NN participated in the evaluating classification accuracy stage. The study was done on IEEE 39-bus. The results showed that the proposed algorithm achieved effective data size reduction and high accuracy classification.


  • Select Location for Load Shedding In Power System

    by Trong Nghia Le, Huy Anh Quyen, Thi Thanh Binh Phan, Ngoc Au Nguyen, Tan Phung Trieu

    When there is a large power imbalance, the frequency of the power system will be declined lower than the allowable value. Therefore, maintaining the frequency within the allowable value is essential. In the case of an emergency control such as a large generator trip, an effective load shedding plan is required to avoid frequency dropping and blackout. This paper introduces a new method for determining the location of the load shedding by using the phase angle sensitivity of two buses. Load shedding is based on the calculation sensitivity from the loads to the generator outage location. The shorter the loads have sensitivity; the larger capacity loads will shed. Experiment results showed the amount of load shedding is lower, the recovery time of frequency and rotor angle are faster than the conventional load shedding.


  • Hybrid Classifier Model for Dynamic Stability Prediction in Power System

    by Ngoc Au Nguyen, Trong Nghia Le, Huy Anh Quyen, Binh Phan Thi Thanh, Thai Binh Nguyen

    The paper proposes a hybrid classifier model for Dynamic Stability Prediction in Power System (DSPPS). The Hybrid Classifier Model (HCM) is included multiple parallel classifiers. Data for dynamic stable state in power system are very large, complex, and non-linear. These lead to making difficult for a single classifier to learn boundaries of classes. While previous works mainly concentrate on a single classifier, this paper focuses on parallel classifiers. The paper proposes using energy of samples for data partition into clusters. Each single classifier only learns a margin of each cluster. Thus, the learning is easier and classification accuracy is higher. To build HCM, feature selection, and data partition are implemented. The HCM is built by Generalize Regression Neural Network. The study is tested on IEEE 39-bus power system network.