Dejan Beslija
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dejan Beslija has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Dalibor Gorenc
2 shared publicationsMirsad Kapetanovic
2 shared publicationsArmin Hajdarovic
EnergoBos ILJIN d.o.o. Sarajevo, Sarajevo, Bosnia and Herzegovina
1 shared publication- Mahir Muratovic
Hitachi Energy Research, Daettwil, 5405 Baden, Switzerland
1 shared publication Sead Delic
Faculty of Electrical Engeenering Sarajevo, University of Sarajevo
1 shared publication
Latest Publications
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (4) , 1619-1624
Enhanced Method for Pressure Rise Calculation in SF6 GIS Due to Fault Arcs
- 1 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (4) , 1619-1624
Enhanced Method for Pressure Rise Calculation in SF6 GIS Due to Fault Arcs
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 74-78
Capacitive current breaking capability estimation for a 145 kV 40 kA GIS circuit breaker
In this paper, the impact of several 145 kV 40 kA GIS (Gas Insulated Switchgear) circuit breaker design parameters, such as length of the main nozzle throat, contact travel and average opening speed, on the estimated breakdown voltage of the contact gap of an interrupter during capacitive current breaking is analyzed. A new approach for breakdown voltage estimation, which provides full correlation between all circuit breaker design parameters and dielectric characteristics of the contact gap and the criterion for breakdown occurrence, was used for this purpose. The estimated capacitive current breaking capability of the circuit breaker was verified by type testing in KEMA High Power Laboratory, the Netherlands.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 74-78
Capacitive current breaking capability estimation for a 145 kV 40 kA GIS circuit breaker
In this paper, the impact of several 145 kV 40 kA GIS (Gas Insulated Switchgear) circuit breaker design parameters, such as length of the main nozzle throat, contact travel and average opening speed, on the estimated breakdown voltage of the contact gap of an interrupter during capacitive current breaking is analyzed. A new approach for breakdown voltage estimation, which provides full correlation between all circuit breaker design parameters and dielectric characteristics of the contact gap and the criterion for breakdown occurrence, was used for this purpose. The estimated capacitive current breaking capability of the circuit breaker was verified by type testing in KEMA High Power Laboratory, the Netherlands.