Romulo Goncalves Bainy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Romulo Goncalves Bainy has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Brian K. Johnson
University of Idaho
3 shared publications - Andy Hoke
National Laboratory of the Rockies (NLR), Golden, CO (United States)
2 shared publications - Cameron J. Kruse
Kauai Island Utility Cooperative, Lihue, HI, USA
2 shared publications - Jing Wang
National Laboratory of the Rockies
2 shared publications - Kleber Melo Silva
Department of Electrical Engineering, University of Braslia, Braslia, Brazil
2 shared publications - Paulo Henrique Barbosa de Souza Pinheiro
University of Idaho
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 166683-166708
Studying the Impact of IEEE 2800 Compliant Controls and Current Limiters of GFL and GFM IBRs on Transmission Line Protection
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 166683-166708
Open AccessStudying the Impact of IEEE 2800 Compliant Controls and Current Limiters of GFL and GFM IBRs on Transmission Line Protection
- 16 October 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 252
Analysis of line distance elements for various IBR controllers and system conditions
- 16 October 2025
- Published by Elsevier in Electric Power Systems Research
- Vol. 252
Analysis of line distance elements for various IBR controllers and system conditions
- 6 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 587-597
Enhanced Generalized Alpha Plane for Numerical Differential Protection Applications
This paper revisits the generalized alpha plane (GAP) formulation applied to differential protection of multi-terminal apparatus. The GAP formulation is improved by aiming for three main goals: 1) control over the internal fault settlement region (FSR); 2) enabling a simple operation characteristic instead of a restraint characteristic; and, 3) The adjustments are not dependent to the device type. For this purpose, the GAP formulation is redefined in terms of two settings, which transform the FSR into a circumference with a controllable center and radius. Thereby, a circular operation characteristic with an adjustable radius is enabled around the FSR, for improved security. To validate and test the performance of the improved GAP, numerous computer simulations have been carried out using Alternative Transients Program on different multi-terminal equipment (i.e., busbars, transmission lines, and power transformers). In addition to that, massive data analysis is held as a means to highlight the GAP's sensibility. The obtained results demonstrate a well-stable pre-fault point, a consistent circular FSR, and the effectiveness of the improved GAP even under severe conditions.
- 6 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 587-597
Enhanced Generalized Alpha Plane for Numerical Differential Protection Applications
This paper revisits the generalized alpha plane (GAP) formulation applied to differential protection of multi-terminal apparatus. The GAP formulation is improved by aiming for three main goals: 1) control over the internal fault settlement region (FSR); 2) enabling a simple operation characteristic instead of a restraint characteristic; and, 3) The adjustments are not dependent to the device type. For this purpose, the GAP formulation is redefined in terms of two settings, which transform the FSR into a circumference with a controllable center and radius. Thereby, a circular operation characteristic with an adjustable radius is enabled around the FSR, for improved security. To validate and test the performance of the improved GAP, numerous computer simulations have been carried out using Alternative Transients Program on different multi-terminal equipment (i.e., busbars, transmission lines, and power transformers). In addition to that, massive data analysis is held as a means to highlight the GAP's sensibility. The obtained results demonstrate a well-stable pre-fault point, a consistent circular FSR, and the effectiveness of the improved GAP even under severe conditions.
- 15 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (4) , 1769-1778
Dynamic Zone Selection for Busbar Protection Based on Graph Theory and Boolean Algebra
- 15 November 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 35 (4) , 1769-1778
Dynamic Zone Selection for Busbar Protection Based on Graph Theory and Boolean Algebra