Latest Publications
- 23 November 2000
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 14 (24) , 2343-2347
Detection of exogenous intake of natural corticosteroids by gas chromatography/combustion/isotope ratio mass spectrometry: application to misuse in sport
A detailed procedure for the analysis of exogenous hydrocortisone and cortisone in urine by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) is proposed. As urinary levels of hydrocortisone are rather low for GC/C/IRMS analysis, the focus is on the main corticosteroid metabolites, tetrahydrocortisone (THE) and tetrahydrocortisol (THF). Following different solid phase extraction purifications, THE and THF are oxidized to 5β‐androstanetrione before analysis by GC/C/IRMS. Significant differences in δ13C‰ values of synthetic natural corticosteroids and endogenous human corticosteroids have been observed. Therefore, a positive criterion, to detect exogenous administration of synthetic corticosteroids in anti‐doping control, is proposed. Copyright © 2000 John Wiley & Sons, Ltd.
- 23 November 2000
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 14 (24) , 2343-2347
Detection of exogenous intake of natural corticosteroids by gas chromatography/combustion/isotope ratio mass spectrometry: application to misuse in sport
A detailed procedure for the analysis of exogenous hydrocortisone and cortisone in urine by gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) is proposed. As urinary levels of hydrocortisone are rather low for GC/C/IRMS analysis, the focus is on the main corticosteroid metabolites, tetrahydrocortisone (THE) and tetrahydrocortisol (THF). Following different solid phase extraction purifications, THE and THF are oxidized to 5β‐androstanetrione before analysis by GC/C/IRMS. Significant differences in δ13C‰ values of synthetic natural corticosteroids and endogenous human corticosteroids have been observed. Therefore, a positive criterion, to detect exogenous administration of synthetic corticosteroids in anti‐doping control, is proposed. Copyright © 2000 John Wiley & Sons, Ltd.