Weiguo Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Weiguo Wang has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Haiyang Li
State Key Laboratory of Medical Proteomics, Dalian Institute of Chemical Physics
4 shared publications Huiwen Ruan
State Key Laboratory of Medical Proteomics, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, People's Republic of China
3 shared publicationsGuiyun Song
Northeastern University, College of Sciences, Research Center for Analytical Sciences, Department of Chemistry, Box 332, Shenyang, 110819, People's Republic of China
2 shared publications- Lei Hua
Dalian Institute of Chemical Physics, Chinese Academy of Sciences
2 shared publications Zhigang Fan
State Key Laboratory of Medical Proteomics, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, 457 Zhongshan Road, Dalian, 116023, People's Republic of China
2 shared publications- Avichal Mehra
NWS/NCEP/EMC, NOAA Center for Weather and Climate Prediction, 5830 University Research Court, College Park, MD 20740, USA
1 shared publication
Latest Publications
- 24 December 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (3) , 597-603
Time-resolved thermal desorption miniature ion trap mass spectrometry for rapid and simultaneous quantification of multiple cooling agents in complex matrices
Miniaturized mass spectrometry has emerged as a powerful analytical technique characterized by its portability, rapid analysis capability, and operational simplicity, making it particularly suitable for on-site detection across various fields. However, the accurate quantitative determination of multiple compounds in complex matrices remains challenging due to factors such as competitive ionization and limited ion storage capacity. In this study, a time-resolved thermal desorption continuous atmospheric pressure interface ion trap mass spectrometer (TRTD-CAPI-ITMS) coupled with an acetone-assisted photoionization source was developed for simultaneous detection of multiple cooling agents for ensuring product safety and quality control. To evaluate the performance of the system, time-resolved thermal desorption curves of cooling agent mixtures with varying boiling points and concentrations were systematically investigated. The prominent signals of all the cooling agents could be observed simultaneously at a thermal desorption time of 2.0 seconds. However, a key challenge was identified during simultaneous quantitation: non-linear concentration-dependent signal responses were observed with increasing cooling agent concentrations. Competitive ionization between the target cooling agents was confirmed as the primary cause of this phenomenon. To address this issue, two critical parameter adjustments were implemented: (1) reducing the sample load to decrease the number of competing analyte components in the ionization region, and (2) elevating the concentration of acetone dimer reagent ions to ensure sufficient reagent ions for effective ionization of the target cooling agents. As a result, competitive ionization was eliminated, and good linear calibration curves were obtained for all four cooling agents, with all linear correlation coefficients (R2) exceeding 0.99. Finally, the TRTD-CAPI-ITMS was applied to the quantitative determination of cooling agents in commercial dentifrice samples, with whole detection time less than 4 minutes, demonstrating the potential of TRTD-CAPI-ITMS as a powerful tool for field detection of cooling agents in complex matrices, with broad applicability in quality control and safety assessment across relevant industries.
- 24 December 2025
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 18 (3) , 597-603
Time-resolved thermal desorption miniature ion trap mass spectrometry for rapid and simultaneous quantification of multiple cooling agents in complex matrices
Miniaturized mass spectrometry has emerged as a powerful analytical technique characterized by its portability, rapid analysis capability, and operational simplicity, making it particularly suitable for on-site detection across various fields. However, the accurate quantitative determination of multiple compounds in complex matrices remains challenging due to factors such as competitive ionization and limited ion storage capacity. In this study, a time-resolved thermal desorption continuous atmospheric pressure interface ion trap mass spectrometer (TRTD-CAPI-ITMS) coupled with an acetone-assisted photoionization source was developed for simultaneous detection of multiple cooling agents for ensuring product safety and quality control. To evaluate the performance of the system, time-resolved thermal desorption curves of cooling agent mixtures with varying boiling points and concentrations were systematically investigated. The prominent signals of all the cooling agents could be observed simultaneously at a thermal desorption time of 2.0 seconds. However, a key challenge was identified during simultaneous quantitation: non-linear concentration-dependent signal responses were observed with increasing cooling agent concentrations. Competitive ionization between the target cooling agents was confirmed as the primary cause of this phenomenon. To address this issue, two critical parameter adjustments were implemented: (1) reducing the sample load to decrease the number of competing analyte components in the ionization region, and (2) elevating the concentration of acetone dimer reagent ions to ensure sufficient reagent ions for effective ionization of the target cooling agents. As a result, competitive ionization was eliminated, and good linear calibration curves were obtained for all four cooling agents, with all linear correlation coefficients (R2) exceeding 0.99. Finally, the TRTD-CAPI-ITMS was applied to the quantitative determination of cooling agents in commercial dentifrice samples, with whole detection time less than 4 minutes, demonstrating the potential of TRTD-CAPI-ITMS as a powerful tool for field detection of cooling agents in complex matrices, with broad applicability in quality control and safety assessment across relevant industries.
- 26 October 2023
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 34 (12) , 2822-2830
Radial Electric Field Driven Collision-Induced Dissociation in a Miniature Continuous Atmospheric Pressure Interfaced Ion Trap Mass Spectrometer
Miniature ion trap mass spectrometry with the unique ability of tandem-in-time analysis is extensively used in public security and environmental pollution detection. In this study, a novel radial electric field driven collision-induced dissociation (REFD-CID) is presented with high fragmentation efficiency for different species by adjusting the float DC, the initial kinetic energy of ions, and the pressure in a miniature continuous atmospheric pressure interfaced ion trap mass spectrometer (CAPI-ITMS). It is noteworthy that multiple fragment ions ([M+H-nC(2)H(4)](+), where n = 1, 2, 3) of triethyl phosphate were observed with a single injection of ions. The underlying mechanism of the REFD-CID revealed that the enhanced radial electric field by modulation of the float DC drove ions toward regions of intense RF field where broadband heating and dissociation of ions took place through theoretical simulations. Finally, the REFD-CID was utilized to improve the instrument performances. The existence of reagent ions led to a severe space charge effect as the ion injection duration of the CAPI-ITMS was extended to enhance the sensitivity of aniline. Through selective fragmentation of reagent ions, peak broadening and mass shift were eliminated, and meanwhile, a 28-fold improvement of aniline in a signal-to-noise ratio was achieved with the ion injection duration varying from 50 to 2500 ms. Moreover, isomeric illicit drugs (JWH-018 and acetylcodeine) were distinguished by generating multiple characteristic fragment ions, demonstrating potential applications in the identification of synthetic illicit drugs.
- 26 October 2023
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 34 (12) , 2822-2830
Radial Electric Field Driven Collision-Induced Dissociation in a Miniature Continuous Atmospheric Pressure Interfaced Ion Trap Mass Spectrometer
Miniature ion trap mass spectrometry with the unique ability of tandem-in-time analysis is extensively used in public security and environmental pollution detection. In this study, a novel radial electric field driven collision-induced dissociation (REFD-CID) is presented with high fragmentation efficiency for different species by adjusting the float DC, the initial kinetic energy of ions, and the pressure in a miniature continuous atmospheric pressure interfaced ion trap mass spectrometer (CAPI-ITMS). It is noteworthy that multiple fragment ions ([M+H-nC(2)H(4)](+), where n = 1, 2, 3) of triethyl phosphate were observed with a single injection of ions. The underlying mechanism of the REFD-CID revealed that the enhanced radial electric field by modulation of the float DC drove ions toward regions of intense RF field where broadband heating and dissociation of ions took place through theoretical simulations. Finally, the REFD-CID was utilized to improve the instrument performances. The existence of reagent ions led to a severe space charge effect as the ion injection duration of the CAPI-ITMS was extended to enhance the sensitivity of aniline. Through selective fragmentation of reagent ions, peak broadening and mass shift were eliminated, and meanwhile, a 28-fold improvement of aniline in a signal-to-noise ratio was achieved with the ion injection duration varying from 50 to 2500 ms. Moreover, isomeric illicit drugs (JWH-018 and acetylcodeine) were distinguished by generating multiple characteristic fragment ions, demonstrating potential applications in the identification of synthetic illicit drugs.
- 1 September 2019
- Published by Elsevier in Scripta Materialia
- Vol. 170, 62-66
Grain boundary inter-connections of ∑5 boundaries in a high purity iron with a uniform microstructure
- 1 September 2019
- Published by Elsevier in Scripta Materialia
- Vol. 170, 62-66
Grain boundary inter-connections of ∑5 boundaries in a high purity iron with a uniform microstructure
- Open Access
- 1 June 2018
- Published by American Meteorological Society in Weather and Forecasting
- Vol. 33 (3) , 887-898
Improving NCEP HWRF Simulations of Surface Wind and Inflow Angle in the Eyewall Area
This note describes a modification of the boundary layer parameterization scheme in the Hurricane Weather Research and Forecasting (HWRF) Model, which improves the simulations of low-level wind and surface inflow angle in the eyewall area and has been implemented in the HWRF system and used in the operational system since 2016. The modification is on an observation-based adjustment of eddy diffusivity previously implemented in the model. It is needed because the previous adjustment resulted in a discontinuity in the vertical distribution of eddy diffusivity near the surface-layer top, which increases the friction within the surface layer and compromises the surface-layer constant-flux assumption. The discontinuity affects the simulation of storm intensity and intensification, one of the main metrics of model performance, particularly in strong tropical cyclones. This issue is addressed by introducing a height-dependent adjustment so that the vertical profile of eddy diffusivity is continuous throughout the boundary layer. It is shown that the implementation of the modification results in low-level winds and surface inflow angles in the storm’s eyewall region closer to observations.
- 1 June 2018
- Published by American Meteorological Society in Weather and Forecasting
- Vol. 33 (3) , 887-898
Open AccessImproving NCEP HWRF Simulations of Surface Wind and Inflow Angle in the Eyewall Area
This note describes a modification of the boundary layer parameterization scheme in the Hurricane Weather Research and Forecasting (HWRF) Model, which improves the simulations of low-level wind and surface inflow angle in the eyewall area and has been implemented in the HWRF system and used in the operational system since 2016. The modification is on an observation-based adjustment of eddy diffusivity previously implemented in the model. It is needed because the previous adjustment resulted in a discontinuity in the vertical distribution of eddy diffusivity near the surface-layer top, which increases the friction within the surface layer and compromises the surface-layer constant-flux assumption. The discontinuity affects the simulation of storm intensity and intensification, one of the main metrics of model performance, particularly in strong tropical cyclones. This issue is addressed by introducing a height-dependent adjustment so that the vertical profile of eddy diffusivity is continuous throughout the boundary layer. It is shown that the implementation of the modification results in low-level winds and surface inflow angles in the storm’s eyewall region closer to observations.
- 1 June 2017
- Published by Elsevier in Chinese Journal of Analytical Chemistry
- Vol. 45 (6) , 851-855
Investigation on Production of Cluster Ions Using Surface-Assisted Laser Desorption/Ionization Mass Spectrometry
- 1 June 2017
- Published by Elsevier in Chinese Journal of Analytical Chemistry
- Vol. 45 (6) , 851-855
Investigation on Production of Cluster Ions Using Surface-Assisted Laser Desorption/Ionization Mass Spectrometry
- 24 December 2015
- Published by Taylor & Francis in Molecular Physics
- Vol. 114 (6) , 855-861
Ellipticity-dependent of multiple ionisation methyl iodide cluster using 532 nm nanosecond laser
The dependence of multiply charged ions on laser ellipticity in methyl iodide clusters with 532 nm nanosecond laser was measured using a time-of-flight mass spectrometer. The intensities of multiply charged ions Iq+(q = 2–4) with circularly polarised laser pulse were clearly higher than those with linearly polarised laser pulse but the intensity of single charged ions I+ was inverse. And the dependences of ions on the optical polarisation state were investigated and a flower petal and square distribution for single charged ions (I+, C+) and multiply charged ions (I2+, I3+, I4+, C2+) were observed, respectively. A theoretical calculation was also proposed to simulate the distributions of ions and theoretical results fitted well with the experimental ones. It indicated that the high multiphoton ionisation probability in the initial stage would result in the disintegration of big clusters into small ones and suppress the production of multiply charged ions.
- 24 December 2015
- Published by Taylor & Francis in Molecular Physics
- Vol. 114 (6) , 855-861
Ellipticity-dependent of multiple ionisation methyl iodide cluster using 532 nm nanosecond laser
The dependence of multiply charged ions on laser ellipticity in methyl iodide clusters with 532 nm nanosecond laser was measured using a time-of-flight mass spectrometer. The intensities of multiply charged ions Iq+(q = 2–4) with circularly polarised laser pulse were clearly higher than those with linearly polarised laser pulse but the intensity of single charged ions I+ was inverse. And the dependences of ions on the optical polarisation state were investigated and a flower petal and square distribution for single charged ions (I+, C+) and multiply charged ions (I2+, I3+, I4+, C2+) were observed, respectively. A theoretical calculation was also proposed to simulate the distributions of ions and theoretical results fitted well with the experimental ones. It indicated that the high multiphoton ionisation probability in the initial stage would result in the disintegration of big clusters into small ones and suppress the production of multiply charged ions.