Ya Zhu
Ya Zhu has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Jialin Liu
State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Shapingba District, Chongqing 400044, China
1 shared publication- Jiping Lu
State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Shapingba District, Chongqing 400044, China
1 shared publication Qian He
State Grid Chongqing Electric Power Company, Chongqing 401120, China
1 shared publication- Zheng Li
School of Automation, Chengdu University of Information Technology, Chengdu 610025, China
1 shared publication
Latest Publications
- Open Access
- 4 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 143746-143758
Resistance Selection and Control Strategy Considering the Coordination of Protection Performance and Low Voltage Ride Through of a Large-Scale Photovoltaic Power Station
Neutral grounding through resistance is widely applied in large-scale centralized grid-connected photovoltaic power stations (PVPS), while protection measures, which are supposed to cut off the single-phase grounding fault of the collection system quickly, are required according to the grid code. Analyses on the coordination between protection performances and low voltage ride through (LVRT) are missing in current researches. Hence there could be a risk that large-scale photovoltaic units may disconnect from the grid as a result of a mismatch between the protection and LVRT. In view of the above, this paper makes contributions in two aspects. Firstly, this paper proposes a scheme on neutral point resistance selection, which is to analyze the influences on protection performances by the fault characteristics of the single-phase grounding fault of the PVPS collection system in different test environments, and then to quantify the speed and the selectivity of the zero-sequence current protection performance as assessment indexes, as required in the coordination between protection performances and LVRT, and in the coordination between protection performances of tie lines and collector lines of the collection system, and finally to select neutral point resistance based on the indexes. Secondly, this paper proposes a comprehensive control strategy on the large-scale PVPS, which can effectively improve the assessment indexes mentioned above of the protection under different active power production scenarios. Finally, a simulation will be conducted to verify the correctness and the feasibility of the resistance selection scheme and the control strategy proposed in this paper.
- 4 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 143746-143758
Open AccessResistance Selection and Control Strategy Considering the Coordination of Protection Performance and Low Voltage Ride Through of a Large-Scale Photovoltaic Power Station
Neutral grounding through resistance is widely applied in large-scale centralized grid-connected photovoltaic power stations (PVPS), while protection measures, which are supposed to cut off the single-phase grounding fault of the collection system quickly, are required according to the grid code. Analyses on the coordination between protection performances and low voltage ride through (LVRT) are missing in current researches. Hence there could be a risk that large-scale photovoltaic units may disconnect from the grid as a result of a mismatch between the protection and LVRT. In view of the above, this paper makes contributions in two aspects. Firstly, this paper proposes a scheme on neutral point resistance selection, which is to analyze the influences on protection performances by the fault characteristics of the single-phase grounding fault of the PVPS collection system in different test environments, and then to quantify the speed and the selectivity of the zero-sequence current protection performance as assessment indexes, as required in the coordination between protection performances and LVRT, and in the coordination between protection performances of tie lines and collector lines of the collection system, and finally to select neutral point resistance based on the indexes. Secondly, this paper proposes a comprehensive control strategy on the large-scale PVPS, which can effectively improve the assessment indexes mentioned above of the protection under different active power production scenarios. Finally, a simulation will be conducted to verify the correctness and the feasibility of the resistance selection scheme and the control strategy proposed in this paper.