Ruth Nicholson Klepfer
Ruth Nicholson Klepfer has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Hernández Madrid
Arrhythmia Unit, Cardiology Department, Ramón y Cajal Hospital, Alcalá University, Madrid, Spain
2 shared publications Alessandro Locatelli
Coronary Unit Department, Cardiology and Electrophysiology, ASST Bergamo Est, Ospedale Bolognini, Seriate, Italy
1 shared publicationD.Curtis Deno
1 shared publication- Dedra H. Fagan
Medtronic, Inc. Mounds View Minnesota USA
1 shared publication - Domenico Facchin
Azienda Sanitaria Universitaria Friuli Centrale – Ospedale Santa Maria della Misericordia , Udine; , Trieste
1 shared publication Eugene S Chung
The Christ Hospital Heart and Vascular Center, The Lindner Center for Research and Education, Cincinnati, OH, USA
1 shared publication
Latest Publications
- Open Access
- 1 June 2019
- Published by Taylor & Francis in ClinicoEconomics and Outcomes Research
- Vol. ume 11, 385-393
Heart failure hospitalization reduction and cost savings achieved by improved delivery of effective biventricular pacing: economic implications of the OLE study under the US setting
Background: The hOLter for Efficacy analysis (OLE) study demonstrated that current device pacing diagnostics overestimate the amount of cardiac resynchronization therapy (CRT) pacing that effectively stimulates the cardiac tissue. Sub-optimal pacing increases mortality, hospitalizations, and associated health-care costs. We sought to estimate the expected number of hospital admissions due to heart failure (HF) and its respective financial impact in patients with maximized effective pacing versus conventional pacing. Methods: A Markov model was developed to project HF hospitalizations and quantify the costs that could be avoided if pacing was maximally effective. OLE data were used to inform the prevalence of ineffective pacing among CRT patients and and average loss of pacing by causes. Adaptive CRT trial data quantified the reduction in underlying hospitalization risk by increasing effective pacing delivered. Survival was informed by a meta-analysis of 5 randomized clinical trials. Costs were analyzed from a US payer perspective. Results: Projected average hospitalizations totaled 4.58 over a lifetime horizon for CRT patients with conventional pacing. Maximizing effective pacing delivery was projected to avoid 1.83 HF admissions/patient over the lifetime. This equates to a savings of 40% (US$22,802) compared with conventional pacing from the Medicare perspective. In a sensitivity analysis, CRT with effective pacing was projected to provide cost savings in all scenarios. Conclusions: Maximized effective pacing leads to a lower number of HF hospitalizations, thus allowing significant cost offsets in the US setting.
- 1 June 2019
- Published by Taylor & Francis in ClinicoEconomics and Outcomes Research
- Vol. ume 11, 385-393
Open AccessHeart failure hospitalization reduction and cost savings achieved by improved delivery of effective biventricular pacing: economic implications of the OLE study under the US setting
Background: The hOLter for Efficacy analysis (OLE) study demonstrated that current device pacing diagnostics overestimate the amount of cardiac resynchronization therapy (CRT) pacing that effectively stimulates the cardiac tissue. Sub-optimal pacing increases mortality, hospitalizations, and associated health-care costs. We sought to estimate the expected number of hospital admissions due to heart failure (HF) and its respective financial impact in patients with maximized effective pacing versus conventional pacing. Methods: A Markov model was developed to project HF hospitalizations and quantify the costs that could be avoided if pacing was maximally effective. OLE data were used to inform the prevalence of ineffective pacing among CRT patients and and average loss of pacing by causes. Adaptive CRT trial data quantified the reduction in underlying hospitalization risk by increasing effective pacing delivered. Survival was informed by a meta-analysis of 5 randomized clinical trials. Costs were analyzed from a US payer perspective. Results: Projected average hospitalizations totaled 4.58 over a lifetime horizon for CRT patients with conventional pacing. Maximizing effective pacing delivery was projected to avoid 1.83 HF admissions/patient over the lifetime. This equates to a savings of 40% (US$22,802) compared with conventional pacing from the Medicare perspective. In a sensitivity analysis, CRT with effective pacing was projected to provide cost savings in all scenarios. Conclusions: Maximized effective pacing leads to a lower number of HF hospitalizations, thus allowing significant cost offsets in the US setting.
- Open Access
- 1 April 2017
- Published by Elsevier in Heart Rhythm
- Vol. 14 (4) , 541-547
Device pacing diagnostics overestimate effective cardiac resynchronization therapy pacing results of the hOLter for Efficacy analysis of CRT (OLÉ CRT) study
- 1 April 2017
- Published by Elsevier in Heart Rhythm
- Vol. 14 (4) , 541-547
Open AccessDevice pacing diagnostics overestimate effective cardiac resynchronization therapy pacing results of the hOLter for Efficacy analysis of CRT (OLÉ CRT) study