VTVolkan Turgul

Volkan Turgul

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Volkan Turgul has a total of 2 co-authors. Here are the top co-authors by number of shared publications:

  • Izzet Kale

    Applied DSP and VLSI Research Group (ADVRG), Department of Engineering, Faculty of Science and Technology, University of Westminster, London, W1W 6UW, United Kingdom

    2 shared publications
  • I. Kale

    Applied DSP and VLSI Research Group (ADVRG), Department of Engineering, Faculty of Science and Technology University of Westminster W1W 6UW London United Kingdom

    1 shared publication

Latest Publications

  • Open Access

    All-digital 1550 nm optical aqueous glucose solution measurement system

    by Volkan Turgul, Izzet Kale

    An all-digital 1550 nm optical measurement system is proposed for measuring the concentration of aqueous solutions of glucose to investigate the feasibility of NIR blood glucose measurements. A microcontroller was used to generate the excitation signal for a 1550 nm laser module as well as generate the reference signal to perform the lock-in amplifier function. A sine wave was generated inside the firmware to drive the laser module through a current DAC. The reference signal was generated by reading the monitor diode inside the laser module through the microcontroller's internal ADC. A cooled photodetector was used to measure the light level where its output was digitized by a 24-bit ADC after analog signal conditioning. The glucose concentration result for the measurement was calculated performing DSP functions using the mentioned signals as set out in this paper. A correlation was successfully observed between measured signal level and glucose concentration.


  • Simulating the Effects of Skin Thickness and Fingerprints to Highlight Problems With Non-Invasive RF Blood Glucose Sensing From Fingertips

    by Volkan Turgul, Izzet Kale

    The non-invasive measurement of blood glucose is a popular research topic where RF/microwave sensing of glucose is one of the promising methods in this area. From the many available measurement sites in the human body, fingertips appear to be a good choice due to a good amount of fresh blood supply and homogeneity in terms of biological layers present. The non-invasive RF measurement of blood glucose relies on the detection of the change in the permittivity of the blood using a resonator as a sensor. However, the change in the permittivity of blood due to the variation in glucose content has a limited range resulting in a very small shift in the sensor's frequency response. Any inconsistency between measurements may hinder the measurement results. These inconsistencies mostly arise from the varied thickness of the biological layers and variation of fingerprints that are unique to every human. Therefore, the effects of biological layers and fingerprints in fingertips were studied in detail and are reported in this paper.


  • Open Access

    Influence of fingerprints and finger positioning on accuracy of RF blood glucose measurement from fingertips

    by V. Turgul, I. Kale

    Non‐invasive blood glucose measurement has attracted great interest from researchers deploying various techniques where microwave sensing is one of them. Microwave resonators are utilised as sensors for measuring the glucose levels. A body part is placed on the sensor for a reading and the measurement principle lies in the change of the dielectric properties of blood with varying levels of glucose. The fingertip is a popular measurement site as there is a good amount of fresh blood supply. The position of the fingertip on the sensor has an effect on the sensor response due to the change in the propagation path of the EM field inside the finger. Moreover, fingerprints also affect the sensor response as the irregular ridges and valleys in the fingerprint introduce air gaps altering the effective permittivity seen by the sensor. The effects of fingerprints as well as finger positioning on the sensor is explored and explained.