All-digital 1550 nm optical aqueous glucose solution measurement system
An all-digital 1550 nm optical measurement system is proposed for measuring the concentration of aqueous solutions of glucose to investigate the feasibility of NIR blood glucose measurements. A microcontroller was used to generate the excitation signal for a 1550 nm laser module as well as generate the reference signal to perform the lock-in amplifier function. A sine wave was generated inside the firmware to drive the laser module through a current DAC. The reference signal was generated by reading the monitor diode inside the laser module through the microcontroller's internal ADC. A cooled photodetector was used to measure the light level where its output was digitized by a 24-bit ADC after analog signal conditioning. The glucose concentration result for the measurement was calculated performing DSP functions using the mentioned signals as set out in this paper. A correlation was successfully observed between measured signal level and glucose concentration.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 462-465
Open AccessAll-digital 1550 nm optical aqueous glucose solution measurement system
An all-digital 1550 nm optical measurement system is proposed for measuring the concentration of aqueous solutions of glucose to investigate the feasibility of NIR blood glucose measurements. A microcontroller was used to generate the excitation signal for a 1550 nm laser module as well as generate the reference signal to perform the lock-in amplifier function. A sine wave was generated inside the firmware to drive the laser module through a current DAC. The reference signal was generated by reading the monitor diode inside the laser module through the microcontroller's internal ADC. A cooled photodetector was used to measure the light level where its output was digitized by a 24-bit ADC after analog signal conditioning. The glucose concentration result for the measurement was calculated performing DSP functions using the mentioned signals as set out in this paper. A correlation was successfully observed between measured signal level and glucose concentration.
- 27 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (22) , 7553-7560
Simulating the Effects of Skin Thickness and Fingerprints to Highlight Problems With Non-Invasive RF Blood Glucose Sensing From Fingertips
The non-invasive measurement of blood glucose is a popular research topic where RF/microwave sensing of glucose is one of the promising methods in this area. From the many available measurement sites in the human body, fingertips appear to be a good choice due to a good amount of fresh blood supply and homogeneity in terms of biological layers present. The non-invasive RF measurement of blood glucose relies on the detection of the change in the permittivity of the blood using a resonator as a sensor. However, the change in the permittivity of blood due to the variation in glucose content has a limited range resulting in a very small shift in the sensor's frequency response. Any inconsistency between measurements may hinder the measurement results. These inconsistencies mostly arise from the varied thickness of the biological layers and variation of fingerprints that are unique to every human. Therefore, the effects of biological layers and fingerprints in fingertips were studied in detail and are reported in this paper.
- 27 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 17 (22) , 7553-7560
Simulating the Effects of Skin Thickness and Fingerprints to Highlight Problems With Non-Invasive RF Blood Glucose Sensing From Fingertips
The non-invasive measurement of blood glucose is a popular research topic where RF/microwave sensing of glucose is one of the promising methods in this area. From the many available measurement sites in the human body, fingertips appear to be a good choice due to a good amount of fresh blood supply and homogeneity in terms of biological layers present. The non-invasive RF measurement of blood glucose relies on the detection of the change in the permittivity of the blood using a resonator as a sensor. However, the change in the permittivity of blood due to the variation in glucose content has a limited range resulting in a very small shift in the sensor's frequency response. Any inconsistency between measurements may hinder the measurement results. These inconsistencies mostly arise from the varied thickness of the biological layers and variation of fingerprints that are unique to every human. Therefore, the effects of biological layers and fingerprints in fingertips were studied in detail and are reported in this paper.
- Open Access
- 1 February 2017
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 53 (4) , 218-220
Influence of fingerprints and finger positioning on accuracy of RF blood glucose measurement from fingertips
Non‐invasive blood glucose measurement has attracted great interest from researchers deploying various techniques where microwave sensing is one of them. Microwave resonators are utilised as sensors for measuring the glucose levels. A body part is placed on the sensor for a reading and the measurement principle lies in the change of the dielectric properties of blood with varying levels of glucose. The fingertip is a popular measurement site as there is a good amount of fresh blood supply. The position of the fingertip on the sensor has an effect on the sensor response due to the change in the propagation path of the EM field inside the finger. Moreover, fingerprints also affect the sensor response as the irregular ridges and valleys in the fingerprint introduce air gaps altering the effective permittivity seen by the sensor. The effects of fingerprints as well as finger positioning on the sensor is explored and explained.
- 1 February 2017
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 53 (4) , 218-220
Open AccessInfluence of fingerprints and finger positioning on accuracy of RF blood glucose measurement from fingertips
Non‐invasive blood glucose measurement has attracted great interest from researchers deploying various techniques where microwave sensing is one of them. Microwave resonators are utilised as sensors for measuring the glucose levels. A body part is placed on the sensor for a reading and the measurement principle lies in the change of the dielectric properties of blood with varying levels of glucose. The fingertip is a popular measurement site as there is a good amount of fresh blood supply. The position of the fingertip on the sensor has an effect on the sensor response due to the change in the propagation path of the EM field inside the finger. Moreover, fingerprints also affect the sensor response as the irregular ridges and valleys in the fingerprint introduce air gaps altering the effective permittivity seen by the sensor. The effects of fingerprints as well as finger positioning on the sensor is explored and explained.