Min Li
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Min Li has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Guomin Zhao
School of Energy and Safety Engineering
2 shared publications Congmin Ma
Grade 14, The Department of Economics, The School of Economics & Management, University of South China, Hengyang, Hunan Province 421001, China
1 shared publicationDaqing Wu
School of Computer Science and Technology, University of South China, Hengyang, Hunan Province 421001, China
1 shared publicationJianjun Jiang
School of Safety and Environment Engineering, Hunan Institute of Technology, Hengyang, Hunan Province 421002, China
1 shared publication- Jie Peng
University of Science and Technology of China
1 shared publication Jin Shuang
School of Energy and Safety Engineering
1 shared publication
Latest Publications
- Open Access
- 1 January 2018
- Published by Wiley in Advances in Civil Engineering
- Vol. 2018 (1)
Analysis of Fire Risk Associated with Photovoltaic Power Generation System
Because of increasing energy consumption and severe air pollution in China, solar photovoltaic power generation plants are being deployed rapidly. Owing to various factors such as technology, construction, and imperfection of construction standards, solar photovoltaic systems have certain fire risks. This paper focuses on the fire risks of building‐integrated solar photovoltaic buildings, as well as temperature and heat flow density near a photovoltaic system in a fire. Based on FDS simulation results, the influence of different building fires on photovoltaic systems is analysed. It is found that the influence of fire on photovoltaic systems installed on a building with a flat roof is stronger than that on a system installed on a building with a sloping roof; the influence of fire on a photovoltaic system installed on a building with external wall thermal insulation is stronger than that on a system installed on a building without such insulation; and in the presence of a skylight, a photovoltaic system installed on a building with a sloping roof is more dangerous.
- 1 January 2018
- Published by Wiley in Advances in Civil Engineering
- Vol. 2018 (1)
Open AccessAnalysis of Fire Risk Associated with Photovoltaic Power Generation System
Because of increasing energy consumption and severe air pollution in China, solar photovoltaic power generation plants are being deployed rapidly. Owing to various factors such as technology, construction, and imperfection of construction standards, solar photovoltaic systems have certain fire risks. This paper focuses on the fire risks of building‐integrated solar photovoltaic buildings, as well as temperature and heat flow density near a photovoltaic system in a fire. Based on FDS simulation results, the influence of different building fires on photovoltaic systems is analysed. It is found that the influence of fire on photovoltaic systems installed on a building with a flat roof is stronger than that on a system installed on a building with a sloping roof; the influence of fire on a photovoltaic system installed on a building with external wall thermal insulation is stronger than that on a system installed on a building without such insulation; and in the presence of a skylight, a photovoltaic system installed on a building with a sloping roof is more dangerous.
- Open Access
- 6 November 2017
- Published by Wiley in Advances in Civil Engineering
- Vol. 2017, 1-7
Study of Split-Flow Wall Located at Exit
Congestion is the major cause of crowd stampede-trampling and crushing incidents. To alleviate the phenomenon of congestion in the process of evacuation, theory of split-flow wall is put forward to optimize the evacuation and the principle of it is analyzed. Based on the occupant evacuation software of buildingEXODUS, the set parameters of the split-flow wall are studied, and we find that the best range of shunt wall length is 1.5–2 times the export width and the best position of the split-flow wall is 0.5 to 0.75 times the export width far from the exit. Shunt wall can effectively alleviate and even eliminate the congestion in the process of evacuation and will not affect safe evacuation when crowd density is low.
- 6 November 2017
- Published by Wiley in Advances in Civil Engineering
- Vol. 2017, 1-7
Open AccessStudy of Split-Flow Wall Located at Exit
Congestion is the major cause of crowd stampede-trampling and crushing incidents. To alleviate the phenomenon of congestion in the process of evacuation, theory of split-flow wall is put forward to optimize the evacuation and the principle of it is analyzed. Based on the occupant evacuation software of buildingEXODUS, the set parameters of the split-flow wall are studied, and we find that the best range of shunt wall length is 1.5–2 times the export width and the best position of the split-flow wall is 0.5 to 0.75 times the export width far from the exit. Shunt wall can effectively alleviate and even eliminate the congestion in the process of evacuation and will not affect safe evacuation when crowd density is low.
- 1 August 2017
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 106, 247-255
Optimal design methods for a digital human-computer interface based on human reliability in a nuclear power plant
- 1 August 2017
- Published by Elsevier in Annals of Nuclear Energy
- Vol. 106, 247-255
Optimal design methods for a digital human-computer interface based on human reliability in a nuclear power plant