Bao Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bao Xie has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
Lin Zhou
State Key Laboratory of Power Transmission Equipment & System Security and New Technology Chongqing University Chongqing People's Republic of China
3 shared publicationsMingxuan Mao
State Key Laboratory of Power Transmission Equipment & System Security and New Technology Chongqing University Chongqing People's Republic of China
3 shared publications- Jianhui Su
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
2 shared publications - Yong Shi
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
2 shared publications - Chong Di
School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
1 shared publication Cunyu Wang
Hefei University of Technology
1 shared publication
Latest Publications
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (12) , 21210-21229
Comprehensive Control Method for Improving Asymmetric Fault Ride-Through Capability of Virtual Synchronous Generators
- 1 December 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (12) , 21210-21229
Comprehensive Control Method for Improving Asymmetric Fault Ride-Through Capability of Virtual Synchronous Generators
- Open Access
- 20 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (22) , 5435
Wideband Oscillation Stability Assessment of Renewable Energy Power Plants Based on Data–Model Fusion
With the increasing penetration of renewable energy generation, dynamic interactions among converter control loops, filters, and grid impedance have become increasingly complex, making wideband oscillation stability a critical concern in renewable energy power plants. This study investigates electromagnetic wideband oscillation stability associated with converter control dynamics, converter–grid impedance interactions, and multi-unit coupling, focusing on the frequency range of 1–3000 Hz. To address the difficulty in accessing the internal control structures and parameters of commercial renewable energy generation units, a data–model fusion approach is employed for plant-level wideband stability assessment. First, a backpropagation (BP) neural network-based admittance identification model is developed using terminal voltage, current, and frequency-sweeping data under different active-power operating conditions, thereby establishing a nonlinear mapping between operating conditions and wideband dq admittance. The identification accuracy and generalization capability of the model are evaluated using the model-development dataset and an independent test dataset, respectively. Second, the offline-trained data-driven unit models are integrated with the physical electrical topology model of the renewable energy power plant. Through admittance transformation between local and global reference frames and impedance-network aggregation based on the nodal admittance matrix, the plant-level wideband equivalent impedance is obtained, and its stability is evaluated using the generalized Nyquist criterion. Based on this approach, a renewable energy power plant comprising 15 photovoltaic generation units is investigated, with particular emphasis on the effects of unit electrical locations and collector-network topology variations on plant-level equivalent impedance characteristics and stability margins. The results demonstrate that variations in unit electrical locations and feeder configurations significantly alter the equivalent impedance characteristics and stability margins of the power plant. The findings reveal the influence of unit electrical locations and collector-network topology on plant-level wideband stability, providing a theoretical reference for operating-mode adjustment and power-output topology optimization in renewable energy power plants.
- 20 November 2026
- Published by MDPI AG in Electronics
- Vol. 15 (22) , 5435
Open AccessWideband Oscillation Stability Assessment of Renewable Energy Power Plants Based on Data–Model Fusion
With the increasing penetration of renewable energy generation, dynamic interactions among converter control loops, filters, and grid impedance have become increasingly complex, making wideband oscillation stability a critical concern in renewable energy power plants. This study investigates electromagnetic wideband oscillation stability associated with converter control dynamics, converter–grid impedance interactions, and multi-unit coupling, focusing on the frequency range of 1–3000 Hz. To address the difficulty in accessing the internal control structures and parameters of commercial renewable energy generation units, a data–model fusion approach is employed for plant-level wideband stability assessment. First, a backpropagation (BP) neural network-based admittance identification model is developed using terminal voltage, current, and frequency-sweeping data under different active-power operating conditions, thereby establishing a nonlinear mapping between operating conditions and wideband dq admittance. The identification accuracy and generalization capability of the model are evaluated using the model-development dataset and an independent test dataset, respectively. Second, the offline-trained data-driven unit models are integrated with the physical electrical topology model of the renewable energy power plant. Through admittance transformation between local and global reference frames and impedance-network aggregation based on the nodal admittance matrix, the plant-level wideband equivalent impedance is obtained, and its stability is evaluated using the generalized Nyquist criterion. Based on this approach, a renewable energy power plant comprising 15 photovoltaic generation units is investigated, with particular emphasis on the effects of unit electrical locations and collector-network topology variations on plant-level equivalent impedance characteristics and stability margins. The results demonstrate that variations in unit electrical locations and feeder configurations significantly alter the equivalent impedance characteristics and stability margins of the power plant. The findings reveal the influence of unit electrical locations and collector-network topology on plant-level wideband stability, providing a theoretical reference for operating-mode adjustment and power-output topology optimization in renewable energy power plants.
- 26 February 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (3) , 193
Modular state-space modelling for stability assessment of multi-converter-based power systems
- 26 February 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (3) , 193
Modular state-space modelling for stability assessment of multi-converter-based power systems
- 16 February 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (3) , 149
Transient stability analysis and improvement of grid-connected inverters during severe grid faults
- 16 February 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (3) , 149
Transient stability analysis and improvement of grid-connected inverters during severe grid faults
- 5 October 2024
- Published by Springer Nature in Journal of Power Electronics
- Vol. 25 (4) , 642-653
Topology and control method of interleaved parallel DC/DC converters with ripple compensation for fuel cell applications
- 5 October 2024
- Published by Springer Nature in Journal of Power Electronics
- Vol. 25 (4) , 642-653
Topology and control method of interleaved parallel DC/DC converters with ripple compensation for fuel cell applications
- Open Access
- 2 November 2023
- Published by Elsevier in Global Energy Interconnection
- Vol. 6 (5) , 592-600
An adaptive control strategy for microgrid secondary frequency based on parameter identification
- 2 November 2023
- Published by Elsevier in Global Energy Interconnection
- Vol. 6 (5) , 592-600
Open AccessAn adaptive control strategy for microgrid secondary frequency based on parameter identification
- 8 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (1) , 1277-1287
PEMFC Fault Diagnosis Based on an Equivalent Circuit and OS-ELM Framework
Most current proton exchange membrane fuel cell (PEMFC) fault diagnosis models are not updated after offline training is completed, so they cannot learn new data features. For this problem, a PEMFC fault diagnosis model based on an equivalent circuit and an online sequential extreme learning machine (OS-ELM) framework is proposed. Under different operating conditions, the range of equivalent circuit element values is different, which is conducive to fault diagnosis. Element values constitute a dataset, from which OS-ELM is used to learn data features, and PEMFC fault diagnosis and isolation can be accomplished. OS-ELM has online learning capability. During the operation of PEMFC, equivalent circuit fitting is performed on multiple sets of sample data obtained using electrical impedance spectroscopy (EIS). Optimized fuzzy C-means (FCM) is used to cluster and partition sample data for online updating of OS-ELM models. The experimental results show that the proposed PEMFC fault diagnosis model not only has the speed and accuracy of fault diagnosis but also has the ability to learn fault characteristics online.
- 8 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (1) , 1277-1287
PEMFC Fault Diagnosis Based on an Equivalent Circuit and OS-ELM Framework
Most current proton exchange membrane fuel cell (PEMFC) fault diagnosis models are not updated after offline training is completed, so they cannot learn new data features. For this problem, a PEMFC fault diagnosis model based on an equivalent circuit and an online sequential extreme learning machine (OS-ELM) framework is proposed. Under different operating conditions, the range of equivalent circuit element values is different, which is conducive to fault diagnosis. Element values constitute a dataset, from which OS-ELM is used to learn data features, and PEMFC fault diagnosis and isolation can be accomplished. OS-ELM has online learning capability. During the operation of PEMFC, equivalent circuit fitting is performed on multiple sets of sample data obtained using electrical impedance spectroscopy (EIS). Optimized fuzzy C-means (FCM) is used to cluster and partition sample data for online updating of OS-ELM models. The experimental results show that the proposed PEMFC fault diagnosis model not only has the speed and accuracy of fault diagnosis but also has the ability to learn fault characteristics online.
- 6 May 2023
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (1) , 373-383
2D FEM Based Fast Approach to Predict Electromagnetic Performances of a Variable-Speed FMaSynRM Considering Skewing Effects
- 6 May 2023
- Published by Springer Nature in Journal of Electrical Engineering & Technology
- Vol. 19 (1) , 373-383
2D FEM Based Fast Approach to Predict Electromagnetic Performances of a Variable-Speed FMaSynRM Considering Skewing Effects
- 5 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 35 (3) , 1453-1464
Analysis and Improved Design of Phase Compensated Proportional Resonant Controllers for Grid-Connected Inverters in Weak Grid
Phase compensated proportional resonant (PR) controllers with phase leading angles embedded into resonant controllers, are used to improve the system stability, when the grid-connected inverter is connected to a weak grid with large grid impedance. However, an inappropriate phase leading angle will cause obvious anti-peak in the magnitude response of phase compensated PR controller. Thus, the phase leading angle should be selected carefully. The conventional phase compensation (CPC) method for selecting the phase leading angle can maximize the system phase margin, but at the expense of large peaks in the magnitude response of sensitivity transfer function. Meanwhile, the bandwidths of resonant controllers will be reduced. In the paper, an improved phase compensation (IPC) method is proposed, which does not cause peaks in the magnitude response of sensitivity transfer function while providing sufficient phase margin. Experimental tests were carried out on a single phase grid-connected inverter. The effectiveness of the proposed method is proved in terms of the steady-state and transient performances, as well as the performance under the grid frequency deviation.
- 5 March 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 35 (3) , 1453-1464
Analysis and Improved Design of Phase Compensated Proportional Resonant Controllers for Grid-Connected Inverters in Weak Grid
Phase compensated proportional resonant (PR) controllers with phase leading angles embedded into resonant controllers, are used to improve the system stability, when the grid-connected inverter is connected to a weak grid with large grid impedance. However, an inappropriate phase leading angle will cause obvious anti-peak in the magnitude response of phase compensated PR controller. Thus, the phase leading angle should be selected carefully. The conventional phase compensation (CPC) method for selecting the phase leading angle can maximize the system phase margin, but at the expense of large peaks in the magnitude response of sensitivity transfer function. Meanwhile, the bandwidths of resonant controllers will be reduced. In the paper, an improved phase compensation (IPC) method is proposed, which does not cause peaks in the magnitude response of sensitivity transfer function while providing sufficient phase margin. Experimental tests were carried out on a single phase grid-connected inverter. The effectiveness of the proposed method is proved in terms of the steady-state and transient performances, as well as the performance under the grid frequency deviation.
- Open Access
- 1 February 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 13 (3) , 557-567
Systematic design of linear quadratic regulator for digitally controlled grid‐connected inverters
It is a challenging task to design controller for the digitally controlled LCL‐filtered grid‐connected inverter to achieve high‐quality grid current, avoid undesired resonance, and offer robust performance against system parameters uncertainties. To address the problem, in this study, the linear quadratic regulator (LQR) for a digitally controlled grid‐connected inverter is proposed. Discrete‐time state‐space model of the inverter is established by discretising the system continuous state‐space equations and taking into account one sampling period delay. Then, a systematic design procedure for selecting the state weighting matrix Q is presented, so that the poles of the closed‐loop system are assigned and the desired performances can be achieved. Moreover, to further attenuate the grid voltage background harmonics, the selective harmonic controllers are designed based on the LQR. Compared with the conventional dual current loop control strategy, the proposed LQR controller can achieve low harmonic distortion, fast dynamic response, and good robustness against system parameters deviations. Finally, time‐domain simulations are carried out in MATLAB/SIMULINK software and experimental tests are performed on the experimental setup. The results have demonstrated the effectiveness of the proposed LQR method.
- 1 February 2020
- Published by Institution of Engineering and Technology (IET) in IET Power Electronics
- Vol. 13 (3) , 557-567
Open AccessSystematic design of linear quadratic regulator for digitally controlled grid‐connected inverters
It is a challenging task to design controller for the digitally controlled LCL‐filtered grid‐connected inverter to achieve high‐quality grid current, avoid undesired resonance, and offer robust performance against system parameters uncertainties. To address the problem, in this study, the linear quadratic regulator (LQR) for a digitally controlled grid‐connected inverter is proposed. Discrete‐time state‐space model of the inverter is established by discretising the system continuous state‐space equations and taking into account one sampling period delay. Then, a systematic design procedure for selecting the state weighting matrix Q is presented, so that the poles of the closed‐loop system are assigned and the desired performances can be achieved. Moreover, to further attenuate the grid voltage background harmonics, the selective harmonic controllers are designed based on the LQR. Compared with the conventional dual current loop control strategy, the proposed LQR controller can achieve low harmonic distortion, fast dynamic response, and good robustness against system parameters deviations. Finally, time‐domain simulations are carried out in MATLAB/SIMULINK software and experimental tests are performed on the experimental setup. The results have demonstrated the effectiveness of the proposed LQR method.