Aaqib Peerzada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aaqib Peerzada has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Wesam Rohouma
College of Engineering and Technology, University of Doha for Science and Technology, Doha 24449, Qatar
4 shared publications - Miroslav M. Begovic
Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA
2 shared publications - Morcos Metry
Renewable Energy & Advanced Power Electronics Research Laboratory, Dept of Electrical & Computer Engineering, Texas A&M University, College Station, USA
2 shared publications - Robert Balog
Department of ECE Texas A&M University College Station Doha TX USA Qatar
2 shared publications - Robert S. Balog
Department of Electrical and Computer Engineering, Texas A&M University, College Station, TX, USA
2 shared publications - Bethel Tarekegne
Pacific Northwest National Laboratory, Richland, USA
1 shared publication
Latest Publications
- 27 July 2026
- Published by Elsevier in Applied Energy
- Vol. 425
Generative modeling for long-term load forecasting with customer energy asset adoption trends
- 27 July 2026
- Published by Elsevier in Applied Energy
- Vol. 425
Generative modeling for long-term load forecasting with customer energy asset adoption trends
- 20 December 2023
- Published by Elsevier in Applied Energy
- Vol. 357
On the impact of tidal generation and energy storage integration in PV-rich electric distribution systems
- 20 December 2023
- Published by Elsevier in Applied Energy
- Vol. 357
On the impact of tidal generation and energy storage integration in PV-rich electric distribution systems
- Open Access
- 14 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 3, 255-270
Analysis of the Capacitor-Less D-STATCOM for Voltage Profile Improvement in Distribution Network With High PV Penetration
Distributed Energy Resources (DERs) have disrupted the traditional electrical system. Grid-connected photovoltaic (PV) systems deliver electric energy closer to the consumer, shifting the paradigm from centralized to distributed generation. The impact of the stochastic PV output power gives rise to potentially rapid voltage fluctuations. Reactive power compensation is needed to regulate the voltage profile to meet the relevant standards. Traditional approaches like switched capacitors cannot provide reactive power that is continuously adjustable at short time scales. This paper examines an alternative distribution static synchronous compensator (D-STATCOM) based on a matrix converter (MC) for the low voltage distribution networks with high PV penetration. This technology can extend service life by using inductors for energy storage. The converter being studied provides ancillary services, including reactive power support; the impact on reliability, operational constraints, and electrical behavior is demonstrated. The contribution of this paper is a detailed analysis and impact study of the capacitor-less D-STATCOM in high PV penetration distribution networks. The significance of this paper is that it studies the behavior of the power electronics converter and its interaction with the power systems without assuming or neglecting details of either. Compensation effects and reliability comparisons between the proposed capacitorless D-STATCOM and the incumbent D-STATCOM technology are also studied in this paper.
- 14 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 3, 255-270
Open AccessAnalysis of the Capacitor-Less D-STATCOM for Voltage Profile Improvement in Distribution Network With High PV Penetration
Distributed Energy Resources (DERs) have disrupted the traditional electrical system. Grid-connected photovoltaic (PV) systems deliver electric energy closer to the consumer, shifting the paradigm from centralized to distributed generation. The impact of the stochastic PV output power gives rise to potentially rapid voltage fluctuations. Reactive power compensation is needed to regulate the voltage profile to meet the relevant standards. Traditional approaches like switched capacitors cannot provide reactive power that is continuously adjustable at short time scales. This paper examines an alternative distribution static synchronous compensator (D-STATCOM) based on a matrix converter (MC) for the low voltage distribution networks with high PV penetration. This technology can extend service life by using inductors for energy storage. The converter being studied provides ancillary services, including reactive power support; the impact on reliability, operational constraints, and electrical behavior is demonstrated. The contribution of this paper is a detailed analysis and impact study of the capacitor-less D-STATCOM in high PV penetration distribution networks. The significance of this paper is that it studies the behavior of the power electronics converter and its interaction with the power systems without assuming or neglecting details of either. Compensation effects and reliability comparisons between the proposed capacitorless D-STATCOM and the incumbent D-STATCOM technology are also studied in this paper.
- Open Access
- 10 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 1, 300-311
Adaptive Model Predictive Controller to Reduce Switching Losses for a Capacitor-Less D-STATCOM
In the post-industrial digital-economy, motors powering manufacturing have been replaced by computers powering ecommerce - with significant financial losses attributable to poor power quality (PQ). At the same time, increasing penetration of distributed generation and constant power loads complicate the job for the electric utilities to deliver high-quality electrical power. Traditionally, voltage source converters provide PQ compensation; the backbone of these converters, however, are large electrolytic capacitors (e-caps), which have well-known failure rates. A D-STATCOM that does not use e-caps was shown to increase the converter service life and increase the reliability of the power system; finite control set model predictive control (MPC) was shown to achieve high fidelity tracking for multi-objective cost functions. However, high fidelity (to achieve low total harmonic distortion) results in high switching frequency, which increases losses and device stresses, and reduces the overall converter reliability. This paper improves the capacitorless D-STATCOM by investigating an adaptive MPC that trades-off high-fidelity performance and switching frequency, subject to IEEE 519 THD standards, to achieve good-enough performance. The method is verified experimentally in a 7.5 kVA D-STATCOM hardware prototype. The results show a reduction in switching frequency by over 30% compared with the MPC methods that prioritize high-fidelity alone.
- 10 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 1, 300-311
Open AccessAdaptive Model Predictive Controller to Reduce Switching Losses for a Capacitor-Less D-STATCOM
In the post-industrial digital-economy, motors powering manufacturing have been replaced by computers powering ecommerce - with significant financial losses attributable to poor power quality (PQ). At the same time, increasing penetration of distributed generation and constant power loads complicate the job for the electric utilities to deliver high-quality electrical power. Traditionally, voltage source converters provide PQ compensation; the backbone of these converters, however, are large electrolytic capacitors (e-caps), which have well-known failure rates. A D-STATCOM that does not use e-caps was shown to increase the converter service life and increase the reliability of the power system; finite control set model predictive control (MPC) was shown to achieve high fidelity tracking for multi-objective cost functions. However, high fidelity (to achieve low total harmonic distortion) results in high switching frequency, which increases losses and device stresses, and reduces the overall converter reliability. This paper improves the capacitorless D-STATCOM by investigating an adaptive MPC that trades-off high-fidelity performance and switching frequency, subject to IEEE 519 THD standards, to achieve good-enough performance. The method is verified experimentally in a 7.5 kVA D-STATCOM hardware prototype. The results show a reduction in switching frequency by over 30% compared with the MPC methods that prioritize high-fidelity alone.
- Open Access
- 1 January 2020
- Published by HICSS Conference Office
On Accelerated Aging of Mechanical Assets in Distribution Systems with Renewable Generation
The integration challenges associated with the widespread adoption of the photovoltaic generation can be divided into operational and the maintenance issues. Work done in recent years has addressed issues like voltage rise and unbalance. Less attention was directed to the maintenance challenges like accelerated aging of mechanically controlled voltage support assets under rapidly changing conditions. In particular, there is need for analysis on the mechanism of accelerated wear and tear of devices such as onload tap changers and capacitor banks exposed to rapid voltage fluctuations. This article focuses on developing aging device models and proposes a novel device, referred to as D-STATCOM, to reduce the impact of non-scheduled distributed generation on aging of mechanically-switched devices commonly used in distribution feeders.
- 1 January 2020
- Published by HICSS Conference Office
Open AccessOn Accelerated Aging of Mechanical Assets in Distribution Systems with Renewable Generation
The integration challenges associated with the widespread adoption of the photovoltaic generation can be divided into operational and the maintenance issues. Work done in recent years has addressed issues like voltage rise and unbalance. Less attention was directed to the maintenance challenges like accelerated aging of mechanically controlled voltage support assets under rapidly changing conditions. In particular, there is need for analysis on the mechanism of accelerated wear and tear of devices such as onload tap changers and capacitor banks exposed to rapid voltage fluctuations. This article focuses on developing aging device models and proposes a novel device, referred to as D-STATCOM, to reduce the impact of non-scheduled distributed generation on aging of mechanically-switched devices commonly used in distribution feeders.
- Open Access
- 1 January 2019
- Published by HICSS Conference Office
Impact of Large Distributed Solar PV Generation on Distribution Voltage Control
The emergence of distributed generation in the low voltage distribution networks has led to new challenges in the regulation of feeder voltages. Of particular significance is the variability associated with the photovoltaic power and its impact on the operation of some of the mechanically switching voltage regulating equipment such as On-load Tap Changers (OLTCs) and switchable capacitor banks. This article attempts to study the effects of increased penetration of distributed generation, in particular photovoltaic power and a sustained load buildup on the operational activity of voltage regulators placed on a radial distribution feeder. Actual feeder load profile and high frequency solar irradiance data has been used with varying levels of PV penetration during the time period which spans an entire year. With the inclusion of some justifiable assumptions, it is concluded that the increased penetration of photo voltaic power adversely affects the operational lifetime of voltage regulating equipment.
- 1 January 2019
- Published by HICSS Conference Office
Open AccessImpact of Large Distributed Solar PV Generation on Distribution Voltage Control
The emergence of distributed generation in the low voltage distribution networks has led to new challenges in the regulation of feeder voltages. Of particular significance is the variability associated with the photovoltaic power and its impact on the operation of some of the mechanically switching voltage regulating equipment such as On-load Tap Changers (OLTCs) and switchable capacitor banks. This article attempts to study the effects of increased penetration of distributed generation, in particular photovoltaic power and a sustained load buildup on the operational activity of voltage regulators placed on a radial distribution feeder. Actual feeder load profile and high frequency solar irradiance data has been used with varying levels of PV penetration during the time period which spans an entire year. With the inclusion of some justifiable assumptions, it is concluded that the increased penetration of photo voltaic power adversely affects the operational lifetime of voltage regulating equipment.