Nicolas L'HEureux
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Nicolas L'HEureux has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Nathalie Dusserre
BioTis – Tissue Bioengineering Laboratory Université de Bordeaux INSERM U1026 Bordeaux France
3 shared publications Todd N. McAllister
Cytograft Tissue Engineering, Inc, Novato, Calif
3 shared publicationsAndrew E Kyles
Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California Davis, Davis, 95616, California, USA
1 shared publicationBraden Victor
Capitol Cardiovascular Imaging Center, 1315 Alhambra Boulevard, Suite 320, Sacramento, 95816, California, USA
1 shared publicationClare R Gregory
Department of Surgical and Radiological Sciences, School of Veterinary Medicine, University of California Davis, Davis, 95616, California, USA
1 shared publicationDavid Gebhart
Cytograft Tissue Engineering Inc., Novato, Calif
1 shared publication
Latest Publications
- Top Cited Papers
- 1 November 2014
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 60 (5) , 1353-1357
First human use of an allogeneic tissue-engineered vascular graft for hemodialysis access
- 1 November 2014
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 60 (5) , 1353-1357
Top Cited PapersFirst human use of an allogeneic tissue-engineered vascular graft for hemodialysis access
- Open Access
- 13 October 2011
- Published by S. Karger AG in Cells Tissues Organs
- Vol. 195 (1-2) , 144-158
The Evolution of Vascular Tissue Engineering and Current State of the Art
Dacron® (polyethylene terephthalate) and Goretex® (expanded polytetrafluoroethylene) vascular grafts have been very successful in replacing obstructed blood vessels of large and medium diameters. However, as diameters decrease below 6 mm, these grafts are clearly outperformed by transposed autologous veins and, particularly, arteries. With approximately 8 million individuals with peripheral arterial disease, over 500,000 patients diagnosed with end-stage renal disease, and over 250,000 patients per year undergoing coronary bypass in the USA alone, there is a critical clinical need for a functional small-diameter conduit [Lloyd-Jones et al., Circulation 2010;121:e46–e215]. Over the last decade, we have witnessed a dramatic paradigm shift in cardiovascular tissue engineering that has driven the field away from biomaterial-focused approaches and towards more biology-driven strategies. In this article, we review the preclinical and clinical efforts in the quest for a tissue-engineered blood vessel that is free of permanent synthetic scaffolds but has the mechanical strength to become a successful arterial graft. Special emphasis is given to the tissue engineering by self-assembly (TESA) approach, which has been the only one to reach clinical trials for applications under arterial pressure.
- 13 October 2011
- Published by S. Karger AG in Cells Tissues Organs
- Vol. 195 (1-2) , 144-158
Open AccessThe Evolution of Vascular Tissue Engineering and Current State of the Art
Dacron® (polyethylene terephthalate) and Goretex® (expanded polytetrafluoroethylene) vascular grafts have been very successful in replacing obstructed blood vessels of large and medium diameters. However, as diameters decrease below 6 mm, these grafts are clearly outperformed by transposed autologous veins and, particularly, arteries. With approximately 8 million individuals with peripheral arterial disease, over 500,000 patients diagnosed with end-stage renal disease, and over 250,000 patients per year undergoing coronary bypass in the USA alone, there is a critical clinical need for a functional small-diameter conduit [Lloyd-Jones et al., Circulation 2010;121:e46–e215]. Over the last decade, we have witnessed a dramatic paradigm shift in cardiovascular tissue engineering that has driven the field away from biomaterial-focused approaches and towards more biology-driven strategies. In this article, we review the preclinical and clinical efforts in the quest for a tissue-engineered blood vessel that is free of permanent synthetic scaffolds but has the mechanical strength to become a successful arterial graft. Special emphasis is given to the tissue engineering by self-assembly (TESA) approach, which has been the only one to reach clinical trials for applications under arterial pressure.
- 4 October 2007
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 357 (14) , 1451-1453
Tissue-Engineered Blood Vessel for Adult Arterial Revascularization
A material that will approach the efficacy of native vein has been widely sought.1 Using autologous cells and a technique termed sheet-based tissue engineering, we were able to produce autologous tissue-engineered blood vessels with physiologic mechanical properties.2 No synthetic or exogenous materials were used; instead, the vessels were created with the use of autologous fibroblasts and endothelial cells harvested from a small biopsy specimen of skin and superficial vein. Here we report on the preliminary use of these tissue-engineered blood vessels in an adult arterial model.
- 4 October 2007
- Published by Massachusetts Medical Society in New England Journal of Medicine
- Vol. 357 (14) , 1451-1453
Tissue-Engineered Blood Vessel for Adult Arterial Revascularization
A material that will approach the efficacy of native vein has been widely sought.1 Using autologous cells and a technique termed sheet-based tissue engineering, we were able to produce autologous tissue-engineered blood vessels with physiologic mechanical properties.2 No synthetic or exogenous materials were used; instead, the vessels were created with the use of autologous fibroblasts and endothelial cells harvested from a small biopsy specimen of skin and superficial vein. Here we report on the preliminary use of these tissue-engineered blood vessels in an adult arterial model.
- 19 February 2006
- Published by Springer Nature in Nature Medicine
- Vol. 12 (3) , 361-365
Human tissue-engineered blood vessels for adult arterial revascularization
There is a crucial need for alternatives to native vein or artery for vascular surgery. The clinical efficacy of synthetic, allogeneic or xenogeneic vessels has been limited by thrombosis, rejection, chronic inflammation and poor mechanical properties. Using adult human fibroblasts extracted from skin biopsies harvested from individuals with advanced cardiovascular disease, we constructed tissue-engineered blood vessels (TEBVs) that serve as arterial bypass grafts in long-term animal models. These TEBVs have mechanical properties similar to human blood vessels, without relying upon synthetic or exogenous scaffolding. The TEBVs are antithrombogenic and mechanically stable for 8 months in vivo. Histological analysis showed complete tissue integration and formation of vasa vasorum. The endothelium was confluent and positive for von Willebrand factor. A smooth muscle–specific α-actin–positive cell population developed within the TEBV, suggesting regeneration of a vascular media. Electron microscopy showed an endothelial basement membrane, elastogenesis and a complex collagen network. These results indicate that a completely biological and clinically relevant TEBV can be assembled exclusively from an individual's own cells.
- 19 February 2006
- Published by Springer Nature in Nature Medicine
- Vol. 12 (3) , 361-365
Human tissue-engineered blood vessels for adult arterial revascularization
There is a crucial need for alternatives to native vein or artery for vascular surgery. The clinical efficacy of synthetic, allogeneic or xenogeneic vessels has been limited by thrombosis, rejection, chronic inflammation and poor mechanical properties. Using adult human fibroblasts extracted from skin biopsies harvested from individuals with advanced cardiovascular disease, we constructed tissue-engineered blood vessels (TEBVs) that serve as arterial bypass grafts in long-term animal models. These TEBVs have mechanical properties similar to human blood vessels, without relying upon synthetic or exogenous scaffolding. The TEBVs are antithrombogenic and mechanically stable for 8 months in vivo. Histological analysis showed complete tissue integration and formation of vasa vasorum. The endothelium was confluent and positive for von Willebrand factor. A smooth muscle–specific α-actin–positive cell population developed within the TEBV, suggesting regeneration of a vascular media. Electron microscopy showed an endothelial basement membrane, elastogenesis and a complex collagen network. These results indicate that a completely biological and clinically relevant TEBV can be assembled exclusively from an individual's own cells.