Jaesik Yoon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jaesik Yoon has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Dong-Joo Kim
Materials Research and Education Center, Auburn University, 275 Wilmore Labs, Auburn, AL 36849, USA
2 shared publications - Choongman Lee
Korea Railroad Research Institute, Uiwang 16105, Korea
1 shared publication - Doohee Lee
Energy Materials Research Center, Korea Research Institute of Chemical Technology (KRICT), Daejeon, 34114, South Korea
1 shared publication - Eunji Lee
Auburn University
1 shared publication - Hyunsang Hwang
Center For Single Atom‐Based Semiconductor Device and the Department of Materials Science and Engineering Pohang University of Science and Technology Pohang Republic of Korea
1 shared publication Joonmyoung Lee
Gwangju Institute of Science and Technology 1 Department of Materials Science and Engineering Gwangju 500-712, South Korea
1 shared publication
Latest Publications
- 6 August 2020
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 3 (8) , 7651-7658
Silver-Nanoparticle-Decorated NiOOH Nanorods for Electrocatalytic Urea Sensing
- 6 August 2020
- Published by American Chemical Society (ACS) in ACS Applied Nano Materials
- Vol. 3 (8) , 7651-7658
Silver-Nanoparticle-Decorated NiOOH Nanorods for Electrocatalytic Urea Sensing
- 1 September 2017
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2017-02 (49) , 2107
Non-Enzymatic Urea Detection Via Using Ag/ZnO Nanorod-Based Catalyst
The level of biological molecules, such as urea, glucose, dopamine, and creatinine has been measured by various sensing platform for biomedical applications. For example, the urea level deviated from the reference values which causes several diseases such as renal and hepatic issues, is closely related to our life. Monitoring of urea is also important for fertilizer production as well as development of indirect hydrogen storage materials. Various types of urea sensors, including enzymatic sensors, have been researched to measure abovementioned molecules, courtesy of high selectivity and sensitivity. However, enzymatic sensors have the stability problems caused by denaturation of enzyme. A various metals or metal oxides, such as Pt, Cu/CuO, Ni/NiO, Zn/ZnO, have been widely investigated for the detection of different molecules. Among them, Ni based catalyst presents better performance in the electro-catalytic oxidation of molecules such as urea and glucose. Although Ni based catalyst has shown a good performance, problems such as degradation and expansion of the Ni based catalyst structure during the oxidation still exist. Moreover, the level of pH to operate the electrode for detecting the bio molecules indicates the alkaline the solution which is inability to perform in the physiological condition of approximately pH 7. In other words, the concentration of OH-anions is a dominant factor in Ni based catalyst. In this study, silver catalyst deposited on a synthesized ZnO rods/ carbon substrate was prepared at low-temperature process for the enzyme-free urea sensor. The morphologies and structural properties of Ag catalyst deposited ZnO rods were analyzed by SEM and XRD, and the quantity of the silver catalyst was measured by EDS. Thereafter electrochemical properties of the electrode were performed. The catalytic effect of Ag/ZnO rods electrode for urea sensing was investigated in terms of sensitivity and selectivity. Detailed discussion on the mechanism of Ag/ZnO rods catalytic effect will be given. References R. Lan, J.T.S. Irvine, S. Tao. “Ammonia and related chemicals as potential indirect hydrogen storage materials.” Int. J. Hydrogen Energy, 37 (2012), pp. 1482–1494 D. Aronson, M.A. Mittleman, A.J. Burger. “Elevated blood urea nitrogen level as a predictor of mortality in patients admitted for decompensated heart failure.” Am. J. Med., 116 (2004), pp. 466–473 G. Dhawan, G. Sumana, B.D. “Malhotra Recent developments in urea biosensors.” J. Biochem. Eng., 44 (2009), pp. 42–45 Y. Wang, H. Xu, J. Zhang, J.G. Li. “Electrochemical sensors for clinic analysis.” Sensors, 8 (2008), pp. 2043–2081 M. Singh, N. Verma, A.K. Garg, N. Redhu. “Urea biosensors.” Sens. Actuators B, 134 (2008), pp. 345–351 V. Vedharathinam, G.G. Botte. “Understanding the electro-catalytic oxidation mechanism of urea on nickel electrodes in alkaline medium.” Electrochim. Acta, 81 (2012), pp. 292–300 Q.F. Yi, W. Huang, W.Q. Yu, L. Li, X.P. Liu. “Hydrothermal synthesis of titanium-supported nickel nanoflakes for electrochemical oxidation of glucose.” Electroanalysis, 20 (2008), pp. 2016–2022 Acknowledgement This work was supported by Agency for Defense Development (ADD) as global cooperative research for high performance and light weight bio-urine based fuel cell (UD160050BD).
- 1 September 2017
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2017-02 (49) , 2107
Non-Enzymatic Urea Detection Via Using Ag/ZnO Nanorod-Based Catalyst
The level of biological molecules, such as urea, glucose, dopamine, and creatinine has been measured by various sensing platform for biomedical applications. For example, the urea level deviated from the reference values which causes several diseases such as renal and hepatic issues, is closely related to our life. Monitoring of urea is also important for fertilizer production as well as development of indirect hydrogen storage materials. Various types of urea sensors, including enzymatic sensors, have been researched to measure abovementioned molecules, courtesy of high selectivity and sensitivity. However, enzymatic sensors have the stability problems caused by denaturation of enzyme. A various metals or metal oxides, such as Pt, Cu/CuO, Ni/NiO, Zn/ZnO, have been widely investigated for the detection of different molecules. Among them, Ni based catalyst presents better performance in the electro-catalytic oxidation of molecules such as urea and glucose. Although Ni based catalyst has shown a good performance, problems such as degradation and expansion of the Ni based catalyst structure during the oxidation still exist. Moreover, the level of pH to operate the electrode for detecting the bio molecules indicates the alkaline the solution which is inability to perform in the physiological condition of approximately pH 7. In other words, the concentration of OH-anions is a dominant factor in Ni based catalyst. In this study, silver catalyst deposited on a synthesized ZnO rods/ carbon substrate was prepared at low-temperature process for the enzyme-free urea sensor. The morphologies and structural properties of Ag catalyst deposited ZnO rods were analyzed by SEM and XRD, and the quantity of the silver catalyst was measured by EDS. Thereafter electrochemical properties of the electrode were performed. The catalytic effect of Ag/ZnO rods electrode for urea sensing was investigated in terms of sensitivity and selectivity. Detailed discussion on the mechanism of Ag/ZnO rods catalytic effect will be given. References R. Lan, J.T.S. Irvine, S. Tao. “Ammonia and related chemicals as potential indirect hydrogen storage materials.” Int. J. Hydrogen Energy, 37 (2012), pp. 1482–1494 D. Aronson, M.A. Mittleman, A.J. Burger. “Elevated blood urea nitrogen level as a predictor of mortality in patients admitted for decompensated heart failure.” Am. J. Med., 116 (2004), pp. 466–473 G. Dhawan, G. Sumana, B.D. “Malhotra Recent developments in urea biosensors.” J. Biochem. Eng., 44 (2009), pp. 42–45 Y. Wang, H. Xu, J. Zhang, J.G. Li. “Electrochemical sensors for clinic analysis.” Sensors, 8 (2008), pp. 2043–2081 M. Singh, N. Verma, A.K. Garg, N. Redhu. “Urea biosensors.” Sens. Actuators B, 134 (2008), pp. 345–351 V. Vedharathinam, G.G. Botte. “Understanding the electro-catalytic oxidation mechanism of urea on nickel electrodes in alkaline medium.” Electrochim. Acta, 81 (2012), pp. 292–300 Q.F. Yi, W. Huang, W.Q. Yu, L. Li, X.P. Liu. “Hydrothermal synthesis of titanium-supported nickel nanoflakes for electrochemical oxidation of glucose.” Electroanalysis, 20 (2008), pp. 2016–2022 Acknowledgement This work was supported by Agency for Defense Development (ADD) as global cooperative research for high performance and light weight bio-urine based fuel cell (UD160050BD).
- 8 December 2008
- Published by AIP Publishing in Applied Physics Letters
- Vol. 93 (23) , 232105
Charge loss behavior of a metal-alumina-nitride-oxide-silicon-type flash memory cell with different levels of charge injection
We found that the charge loss behavior of metal-alumina-nitride-oxide-silicon-type flash memory was highly dependent on the amount of injected charge . Beyond the critical level of , the direction of the dominant charge loss changed from pointing toward to pointing toward . The highly injected charges could cause the band bending of , which reduced the tunneling distance across with the low conduction band offset. These results were verified by experimental results and theoretical device modeling through a comparison of the charge loss rate and the tunneling rate between a stack and a stack.- 8 December 2008
- Published by AIP Publishing in Applied Physics Letters
- Vol. 93 (23) , 232105
Charge loss behavior of a metal-alumina-nitride-oxide-silicon-type flash memory cell with different levels of charge injection
We found that the charge loss behavior of metal-alumina-nitride-oxide-silicon-type flash memory was highly dependent on the amount of injected charge . Beyond the critical level of , the direction of the dominant charge loss changed from pointing toward to pointing toward . The highly injected charges could cause the band bending of , which reduced the tunneling distance across with the low conduction band offset. These results were verified by experimental results and theoretical device modeling through a comparison of the charge loss rate and the tunneling rate between a stack and a stack.