CGCarlo Jan Pati Garingarao

Carlo Jan Pati Garingarao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carlo Jan Pati Garingarao has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Cecilia A Jimeno

    Department of Pharmacology, University of the Philippines, College of Medicine, Manila, NCR, Philippines

    1 shared publication
  • Cecilia Alegado Jimeno

    Section of Endocrinology, Diabetes and Metabolism, Department of Medicine, University of the Philippines-Philippine General Hospital, Manila, Philippines

    1 shared publication
  • Cecille Añonuevo-Cruz

    Department of Medicine, Section of Endocrinology, Diabetes and Metabolism, University of the Philippines—Philippine General Hospital, Manila, NCR, Philippines

    1 shared publication
  • Elizabeth Paz-Pacheco

    Department of Medicine; Section of Endocrinology, Diabetes and Metabolism, University of the Philippines, Philippine General Hospital, Manila, NCR, Philippines

    1 shared publication
  • Mark Anthony Santiago Sandoval

    College of Medicine and Philippine General Hospital, University of the Philippines Manila, Philippines

    1 shared publication
  • Myrna Buenaluz-Sedurante

    University of the Philippines College of Medicine, Manila

    1 shared publication

Latest Publications

  • Open Access

    Accuracy of Point-of-Care Blood Glucose Measurements in Critically Ill Patients in Shock

    by Carlo Jan Pati-An Garingarao, Myrna Buenaluz-Sedurante, Cecilia Alegado Jimeno

    Background: A widely used method in monitoring glycemic status of ICU patients is point-of-care (POC) monitoring devices. A possible limitation to this method is altered peripheral blood flow in patients in shock, which may result in over/underestimations of their true glycemic status. Methods: This study aims to determine the accuracy of blood glucose measurements with a POC meter compared to laboratory methods in critically ill patients in shock. POC blood glucose was measured with a glucose-1-dehydrogenase-based reflectometric meter. The reference method was venous plasma glucose measured by a clinical chemistry analyzer (glucose oxidase-based). Outcomes assessed were concordance to ISO 15197:2003 minimum accuracy criteria for glucose meters, bias in glucose measurements obtained by the 2 methods using Bland–Altman analysis, and clinical accuracy through modified error grid analysis. Results: A total of 186 paired glucose measurements were obtained. ISO 2003 accuracy criteria were met in 95.7% and 79.8% of POC glucose values in the normotensive and hypotensive group, respectively. Mean bias for the normotensive group was –12.4 mg/dL, while mean bias in the hypotensive group was –34.9 mg/dL. Conclusions: POC glucose measurements within the target zone for clinical accuracy were 90.2% and 79.8% for the normotensive and hypotensive group, respectively. POC blood glucose measurements were significantly less accurate in the hypotensive subgroup of ICU patients compared to the normotensive group. We recommend a lower threshold in confirming POC blood glucose with a central laboratory method if clinically incompatible. In light of recently updated accuracy standards, we also recommend alternative methods of glucose monitoring for the ICU population as a whole regardless of blood pressure status.


  • Open Access

    Primary hyperparathyroidism from a probable ectopic parathyroid adenoma with severe skeletal disease and vitamin D deficiency

    by Carlo Jan P Garingarao, Elizabeth Paz-Pacheco, Cecilia A Jimeno

    Primary hyperparathyroidism (PHPT) may lead to skeletal deformities, fractures and renal failure in symptomatic patients if untreated. We present a case of a 30-year-old woman presented with muscle weakness, weight loss, hypercalcaemia and a pathological fracture, eventually with rapidly progressive musculoskeletal disease. Subsequent biochemical, radiographic and scintigraphy findings were consistent with PHPT from an ectopic mediastinal adenoma, and concomitant vitamin D deficiency. The severe hypercalcaemia was adequately temporised with hydration, forced diuresis and intravenous bisphosphonates. Removal of the adenoma by video-assisted thoracoscopic surgery was contemplated; however, consent was withdrawn precluding histological confirmation. A review of literature shows the changing profiles of patients with PHPT, the uncommon occurrence of parathyroid adenomas in ectopic locations and possible association between severity of PHPT and vitamin D status.


  • Open Access

    The case of the missing wrist: a probable case of idiopathic osteolysis

    by Carlo Jan Pati Garingarao, Mark Anthony Santiago Sandoval


  • Open Access

    Acute respiratory failure in a rapidly enlarging benign cervical goitre

    by Carlo Jan Garingarao, Cecille Añonuevo-Cruz, Ryan Gasacao

    Benign goitres have the potential to reach massive sizes if neglected, but most have a protracted course that may or may not present with compressive symptoms. We report the case of a 57-year-old man who presented with a rapidly enlarging nodular goitre resulting in acute respiratory failure. Endotracheal intubation and emergency total thyroidectomy were performed, revealing massive thyroid nodules with minimal intrathoracic extension and tracheal erosion. Despite a course and clinical findings suggestive of malignant disease, histopathology was consistent with a benign multinodular goitre. Several cases of benign goitres necessitating endotracheal intubation have been reported. Airway compromise was attributed to a significant intrathoracic component, or inciting events such as thyroid haemorrhage, pregnancy, radioiodine uptake or major surgery. Obstructive symptoms may not correlate well with objective measures of upper airway obstruction such as radiographs or flow volume loops.