Lin Shu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Lin Shu has a total of 198 co-authors. Here are the top co-authors by number of shared publications:
- Xiangmin Xu
South China University of Technology
13 shared publications Xiangmin Xu
School of Microelectronics, and School of EIE, South China University of Technology, Guangzhou, China
7 shared publicationsHaoqiang Hua
South China University of Technology
5 shared publicationsJianlin Ou
Department of Rehabilitation Medicine, The First Affiliated Hospital of Jinan University, Guangzhou, China
5 shared publications- Qing Zeng
Center of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China
5 shared publications Hongbo Yao
School of Future Technology, South China University of Technology, Guangzhou, China
4 shared publications
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (21) , 49357-49374
A Noncontact Capacitive ECG Smart Mattress System Using Sensor Arrays and Adaptive Switching Strategy for Unconstrained In-Bed Sleep
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 13 (21) , 49357-49374
A Noncontact Capacitive ECG Smart Mattress System Using Sensor Arrays and Adaptive Switching Strategy for Unconstrained In-Bed Sleep
- Open Access
- 23 September 2026
- Published by Springer Nature in Advanced Fiber Materials
- p. 1-15
Liquid-Metal-Enabled, Bifunctional Core-Sheath Metafibers for Sensitive Biomotion Sensing and Radiative Personal Thermal Management
- 23 September 2026
- Published by Springer Nature in Advanced Fiber Materials
- p. 1-15
Open AccessLiquid-Metal-Enabled, Bifunctional Core-Sheath Metafibers for Sensitive Biomotion Sensing and Radiative Personal Thermal Management
- Open Access
- 11 September 2026
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 14, e101026
Radiographic Knee Osteoarthritis Identification Using Wearable Plantar Pressure: Secondary Cross-Sectional Analysis of Interpretable Framework Integrating Biomechanical Descriptors and the Multiscale Synergy Index
Background: Radiographic knee osteoarthritis (ROA) is associated with abnormal plantar loading and altered gait coordination. Insole-based plantar-pressure sensing offers a practical wearable approach to ROA identification, but existing methods typically use either conventional biomechanical descriptors or end-to-end temporal models. An interpretable subject-level framework that captures both local abnormalities and distributed coordination is, therefore, needed. Objective: This study aimed to develop an interpretable subject-level framework that combines conventional biomechanical descriptors with coordination-level plantar information to identify ROA. Methods: In secondary cross-sectional analysis, using a previously reported Pearl River Osteoarthritis Cohort plantar-pressure dataset from our group, we analyzed 92 participants (43 with ROA and 49 without ROA; mean age 63.0, SD 8.4 y). The source cohort was recruited from clinical and nearby community sources at Zhujiang Hospital of Southern Medical University, Guangzhou, China, between January 2022 and February 2023. We developed an interpretable participant-level classification framework integrating conventional biomechanical descriptors with a coordination-level Plantar Synergy Index (PSI). Participant-wise stratified split allocated 72 participants for 5-fold cross-validation, and 20 for locked independent evaluation. Feature selection used Fisher-score ranking (k=50). All point estimates are accompanied by 2000-iteration bootstrap 95% CIs, and paired model comparisons used DeLong tests. All statistical tests used α=.05. Additional analyses examined feature stability, phase-resolved PSI patterns, robustness to perturbation and design variation, and comparisons with representative end-to-end temporal baselines. Results: The fusion model achieved the best primary classification performance on the independent test set, with an F 1 -score of 0.842 (95% CI 0.615‐1.000) and accuracy of 0.850 (95% CI 0.700‐1.000). It also showed balanced performance across additional metrics, with area under the receiver operating characteristic curve (AUROC) of 0.818 (95% CI 0.576‐1.000), precision of 0.800 (95% CI 0.538‐1.000), recall of 0.889 (95% CI 0.636‐1.000), and specificity of 0.818 (95% CI 0.571‐1.000). DeLong testing showed that fusion outperformed PSI-only at the AUROC level ( P =.02). Stable retained descriptors were dominated by biomechanical features, with a reproducible PSI component. Phase-resolved analyses suggested distributed stance-phase coordination differences. Robustness and baseline comparisons supported the stability of the framework, but the wide CIs indicate that the findings remain preliminary. Conclusions: This study introduces an interpretable participant-level representation that integrates local biomechanical loading with multiscale interregional temporal coordination, extending plantar-pressure approaches based on summary descriptors or end-to-end models. Across evaluated settings, the framework showed competitive identification and preliminary robustness. Local biomechanical descriptors constituted the main discriminative basis, whereas PSI contributed a reproducible coordination-level component whose incremental predictive value remains to be established. This broadens plantar-pressure analysis from local loading to distributed coordination. External multicenter prospective validation is required before evaluating the framework as an imaging adjunct for functional assessment and longitudinal monitoring.
- 11 September 2026
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 14, e101026
Open AccessRadiographic Knee Osteoarthritis Identification Using Wearable Plantar Pressure: Secondary Cross-Sectional Analysis of Interpretable Framework Integrating Biomechanical Descriptors and the Multiscale Synergy Index
Background: Radiographic knee osteoarthritis (ROA) is associated with abnormal plantar loading and altered gait coordination. Insole-based plantar-pressure sensing offers a practical wearable approach to ROA identification, but existing methods typically use either conventional biomechanical descriptors or end-to-end temporal models. An interpretable subject-level framework that captures both local abnormalities and distributed coordination is, therefore, needed. Objective: This study aimed to develop an interpretable subject-level framework that combines conventional biomechanical descriptors with coordination-level plantar information to identify ROA. Methods: In secondary cross-sectional analysis, using a previously reported Pearl River Osteoarthritis Cohort plantar-pressure dataset from our group, we analyzed 92 participants (43 with ROA and 49 without ROA; mean age 63.0, SD 8.4 y). The source cohort was recruited from clinical and nearby community sources at Zhujiang Hospital of Southern Medical University, Guangzhou, China, between January 2022 and February 2023. We developed an interpretable participant-level classification framework integrating conventional biomechanical descriptors with a coordination-level Plantar Synergy Index (PSI). Participant-wise stratified split allocated 72 participants for 5-fold cross-validation, and 20 for locked independent evaluation. Feature selection used Fisher-score ranking (k=50). All point estimates are accompanied by 2000-iteration bootstrap 95% CIs, and paired model comparisons used DeLong tests. All statistical tests used α=.05. Additional analyses examined feature stability, phase-resolved PSI patterns, robustness to perturbation and design variation, and comparisons with representative end-to-end temporal baselines. Results: The fusion model achieved the best primary classification performance on the independent test set, with an F 1 -score of 0.842 (95% CI 0.615‐1.000) and accuracy of 0.850 (95% CI 0.700‐1.000). It also showed balanced performance across additional metrics, with area under the receiver operating characteristic curve (AUROC) of 0.818 (95% CI 0.576‐1.000), precision of 0.800 (95% CI 0.538‐1.000), recall of 0.889 (95% CI 0.636‐1.000), and specificity of 0.818 (95% CI 0.571‐1.000). DeLong testing showed that fusion outperformed PSI-only at the AUROC level ( P =.02). Stable retained descriptors were dominated by biomechanical features, with a reproducible PSI component. Phase-resolved analyses suggested distributed stance-phase coordination differences. Robustness and baseline comparisons supported the stability of the framework, but the wide CIs indicate that the findings remain preliminary. Conclusions: This study introduces an interpretable participant-level representation that integrates local biomechanical loading with multiscale interregional temporal coordination, extending plantar-pressure approaches based on summary descriptors or end-to-end models. Across evaluated settings, the framework showed competitive identification and preliminary robustness. Local biomechanical descriptors constituted the main discriminative basis, whereas PSI contributed a reproducible coordination-level component whose incremental predictive value remains to be established. This broadens plantar-pressure analysis from local loading to distributed coordination. External multicenter prospective validation is required before evaluating the framework as an imaging adjunct for functional assessment and longitudinal monitoring.
- Open Access
- 14 August 2026
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 14, 1890356
Fall risk assessment via multi-batch plantar pressure data fusion: an ensemble framework integrating global and local features
Introduction: Falls seriously threaten the health and independence of older adults. Existing plantar pressure‐based fall risk assessment methods often rely on single datasets and global features, limiting generalizability across data distributions. Methods: To enhance cross-batch robustness, this study integrated plantar pressure data from two independent batches with inherent distributional differences. Eighty older adults performed a 2‐min walking task while pressure signals were collected using an intelligent footwear system. A feature set of 44 global and 456 local features was constructed, and a four‐model ensemble comprising two MLPs and two 1D‐CNNs was developed. Model performance was evaluated using 8‐fold stratified cross‐validation, Mann–Whitney U‐based pre‐selection, and SHAP/Grad‐CAM interpretability analyses. Results: The ensemble achieved an overall accuracy of 86.25%, outperforming the best single model (MLP1, 80.0%). Performance remained stable across the two batches, with accuracies of 86.0% and 86.7%, corresponding to a fluctuation of 0.7 percentage points. This fluctuation was substantially lower than those observed for the single models; for example, CNN2 fluctuated by 9.3 percentage points. Discussion: These findings suggest that fusing multi‐batch plantar pressure data with an ensemble integrating global and local features can help mitigate the impact of cross-batch distribution shifts on model performance and improve the stability of fall risk assessment, thereby providing a methodological basis for its translation from research settings to practical applications.
- 14 August 2026
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 14, 1890356
Open AccessFall risk assessment via multi-batch plantar pressure data fusion: an ensemble framework integrating global and local features
Introduction: Falls seriously threaten the health and independence of older adults. Existing plantar pressure‐based fall risk assessment methods often rely on single datasets and global features, limiting generalizability across data distributions. Methods: To enhance cross-batch robustness, this study integrated plantar pressure data from two independent batches with inherent distributional differences. Eighty older adults performed a 2‐min walking task while pressure signals were collected using an intelligent footwear system. A feature set of 44 global and 456 local features was constructed, and a four‐model ensemble comprising two MLPs and two 1D‐CNNs was developed. Model performance was evaluated using 8‐fold stratified cross‐validation, Mann–Whitney U‐based pre‐selection, and SHAP/Grad‐CAM interpretability analyses. Results: The ensemble achieved an overall accuracy of 86.25%, outperforming the best single model (MLP1, 80.0%). Performance remained stable across the two batches, with accuracies of 86.0% and 86.7%, corresponding to a fluctuation of 0.7 percentage points. This fluctuation was substantially lower than those observed for the single models; for example, CNN2 fluctuated by 9.3 percentage points. Discussion: These findings suggest that fusing multi‐batch plantar pressure data with an ensemble integrating global and local features can help mitigate the impact of cross-batch distribution shifts on model performance and improve the stability of fall risk assessment, thereby providing a methodological basis for its translation from research settings to practical applications.
- Open Access
- 10 February 2026
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 23 (1)
Dynamic current ratio control and biophysical modeling for personalised electro-tactile perception
The rapid development of virtual reality and human-computer interaction technology has put forward higher requirements for the authenticity and user experi
- 10 February 2026
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 23 (1)
Open AccessDynamic current ratio control and biophysical modeling for personalised electro-tactile perception
The rapid development of virtual reality and human-computer interaction technology has put forward higher requirements for the authenticity and user experi
- 31 January 2026
- Published by Springer Nature
- p. 532-544
Bluetooth Low Energy Time Synchronization Based on Application Layer Events for Multiple Wearable Devices
- 31 January 2026
- Published by Springer Nature
- p. 532-544
Bluetooth Low Energy Time Synchronization Based on Application Layer Events for Multiple Wearable Devices
- Open Access
- 12 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Cyborg and Bionic Systems
- Vol. 7
Wearable Fabric Electrotactile System for VR with Surround-Inhibitory Electrodes Units
Tactile feedback is crucial for enhancing the virtual-reality (VR) interaction experience. However, current electrotactile devices suffer from issues such as current diffusion and electrode crosstalk, limiting spatial accuracy. To address this challenge, we designed a fabric-based ultrathin flexible microelectrode array with novel stimulation–inhibition electrode units that reduces current diffusion and improves focusing, improving tactile feedback accuracy and clarity. Additionally, we developed an electrical tactile interaction evaluation system to quantitatively assess the tactile recognition accuracy and reaction time of 30 participants. Experimental results demonstrate that the proposed electrode structure and evaluation system substantially enhance tactile perception in VR environments. This system has been demonstrated through immersive scenarios such as touching running water, stroking a bird’s forehead, and feeling a cactus, highlighting its potential for providing precise tactile feedback and enhancing personalized human–computer interaction in VR.
- 12 January 2026
- Published by American Association for the Advancement of Science (AAAS) in Cyborg and Bionic Systems
- Vol. 7
Open AccessWearable Fabric Electrotactile System for VR with Surround-Inhibitory Electrodes Units
Tactile feedback is crucial for enhancing the virtual-reality (VR) interaction experience. However, current electrotactile devices suffer from issues such as current diffusion and electrode crosstalk, limiting spatial accuracy. To address this challenge, we designed a fabric-based ultrathin flexible microelectrode array with novel stimulation–inhibition electrode units that reduces current diffusion and improves focusing, improving tactile feedback accuracy and clarity. Additionally, we developed an electrical tactile interaction evaluation system to quantitatively assess the tactile recognition accuracy and reaction time of 30 participants. Experimental results demonstrate that the proposed electrode structure and evaluation system substantially enhance tactile perception in VR environments. This system has been demonstrated through immersive scenarios such as touching running water, stroking a bird’s forehead, and feeling a cactus, highlighting its potential for providing precise tactile feedback and enhancing personalized human–computer interaction in VR.
- Open Access
- 12 January 2026
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 13, 1703500
Balance and fall-risk assessment in older adults using wearable plantar pressure and semi-supervised learning
Falls are a major public health concern among older adults, leading to disability, reduced independence, and high healthcare costs. Conventional balance assessments such as the Berg Balance Scale are limited by subjectivity, time requirements, and dependence on trained evaluators, creating barriers for large-scale community application. To address these challenges, we developed an intelligent footwear system combined with a semi-supervised learning framework to objectively predict Berg Balance Scale scores and assess fall risk. In a study of 136 older adults aged 60–90, plantar pressure signals from smart insoles with eight sensors per foot were collected, and 156 biomechanical features were extracted. A multi-model error consistency approach was applied to mitigate label noise, and feature selection identified ten interpretable predictors related to pressure duration, peak intensity, and inter-limb symmetry. The model achieved root mean square errors of 3.99 in validation and 3.13 in an independent test group. This wearable-based, interpretable, and scalable approach provides a practical solution for early detection of fall risk, enabling timely community interventions and supporting healthy aging strategies in public health.
- 12 January 2026
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 13, 1703500
Open AccessBalance and fall-risk assessment in older adults using wearable plantar pressure and semi-supervised learning
Falls are a major public health concern among older adults, leading to disability, reduced independence, and high healthcare costs. Conventional balance assessments such as the Berg Balance Scale are limited by subjectivity, time requirements, and dependence on trained evaluators, creating barriers for large-scale community application. To address these challenges, we developed an intelligent footwear system combined with a semi-supervised learning framework to objectively predict Berg Balance Scale scores and assess fall risk. In a study of 136 older adults aged 60–90, plantar pressure signals from smart insoles with eight sensors per foot were collected, and 156 biomechanical features were extracted. A multi-model error consistency approach was applied to mitigate label noise, and feature selection identified ten interpretable predictors related to pressure duration, peak intensity, and inter-limb symmetry. The model achieved root mean square errors of 3.99 in validation and 3.13 in an independent test group. This wearable-based, interpretable, and scalable approach provides a practical solution for early detection of fall risk, enabling timely community interventions and supporting healthy aging strategies in public health.
- 12 September 2025
- Published by Springer Nature
- p. 128-140
PhysMamba: Synergistic State Space Duality Model for Remote Physiological Measurement
- 12 September 2025
- Published by Springer Nature
- p. 128-140
PhysMamba: Synergistic State Space Duality Model for Remote Physiological Measurement
- 30 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 12 (16) , 33437-33454
QRS Complexes Detection Using UNet-BiLSTM Model Combined With Adaptive Post-Processing for Multilead Wearable ECG Smart T-Shirt System
In recent years, the rapid development of wearable devices and Internet of Things (IoT) technology has made realtime, continuous dynamic electrocardiogram (ECG) monitoring possible. However, robust universal multi-lead QRS complex detection under noise and high heart rate (HR) conditions remains challenging. In this study, we propose a smart T-shirtbased multi-lead dynamic ECG monitoring system and a highaccuracy QRS complex detection algorithm to solve the above problems. First, we develop a six-lead smart T-shirt system with integrated flexible dry electrodes for real-time acquisition of the ECG under three conditions: standing, walking, and jogging. The electrode structure and hardware circuit are designed to resist noise, while electrodes are combined with medical-grade conductive gels to replace conventional Ag/AgCl wet electrodes, ultimately realizing high signal-to-noise ratio (SNR) signal acquisition under dynamic conditions. The T-shirt-based system design not only enhances user comfort but also facilitates use for non-medical users, making long-term ECG monitoring more feasible. Second, we propose a novel Pro-APP algorithm combining the UNet and bidirectional long short-term memory (UNet-BiLSTM) model with adaptive post-processing (APP), which is robust and outperforms three existing QRS complex detection algorithms. The UNet-BiLSTM model can effectively extract multi-scale features and capture the timing information in the ECG. The APP algorithm further optimizes the R-peak localization by dynamically adjusting parameters. The results show that the system confirms the reliability of its signal quality, HR detection, and electrode performance through the signal quality assessment (SNR ≥ 24 dB), ECG simulator validation (RR interval error.4 ms), and skin-electrode impedance measurement (impedance≤117.27 KΩ at frequencies above 10 Hz). In addition, the Pro-APP algorithm significantly improves the sensitivity (93.67%), precision (97.13%), accuracy (91.08%), and F1-score (95.30%) for detecting QRS complexes, with a mean absolute error of only 3.63 ms, which achieves universal QRS complex detection in multi-lead ECG signals and optimizes wearable dynamic ECG monitoring. The research shows that the smart Tshirt system combined with the QRS complex detection algorithm can provide an important carrier and technical means for the new model of wise information technology of medicine.
- 30 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Internet of Things Journal
- Vol. 12 (16) , 33437-33454
QRS Complexes Detection Using UNet-BiLSTM Model Combined With Adaptive Post-Processing for Multilead Wearable ECG Smart T-Shirt System
In recent years, the rapid development of wearable devices and Internet of Things (IoT) technology has made realtime, continuous dynamic electrocardiogram (ECG) monitoring possible. However, robust universal multi-lead QRS complex detection under noise and high heart rate (HR) conditions remains challenging. In this study, we propose a smart T-shirtbased multi-lead dynamic ECG monitoring system and a highaccuracy QRS complex detection algorithm to solve the above problems. First, we develop a six-lead smart T-shirt system with integrated flexible dry electrodes for real-time acquisition of the ECG under three conditions: standing, walking, and jogging. The electrode structure and hardware circuit are designed to resist noise, while electrodes are combined with medical-grade conductive gels to replace conventional Ag/AgCl wet electrodes, ultimately realizing high signal-to-noise ratio (SNR) signal acquisition under dynamic conditions. The T-shirt-based system design not only enhances user comfort but also facilitates use for non-medical users, making long-term ECG monitoring more feasible. Second, we propose a novel Pro-APP algorithm combining the UNet and bidirectional long short-term memory (UNet-BiLSTM) model with adaptive post-processing (APP), which is robust and outperforms three existing QRS complex detection algorithms. The UNet-BiLSTM model can effectively extract multi-scale features and capture the timing information in the ECG. The APP algorithm further optimizes the R-peak localization by dynamically adjusting parameters. The results show that the system confirms the reliability of its signal quality, HR detection, and electrode performance through the signal quality assessment (SNR ≥ 24 dB), ECG simulator validation (RR interval error.4 ms), and skin-electrode impedance measurement (impedance≤117.27 KΩ at frequencies above 10 Hz). In addition, the Pro-APP algorithm significantly improves the sensitivity (93.67%), precision (97.13%), accuracy (91.08%), and F1-score (95.30%) for detecting QRS complexes, with a mean absolute error of only 3.63 ms, which achieves universal QRS complex detection in multi-lead ECG signals and optimizes wearable dynamic ECG monitoring. The research shows that the smart Tshirt system combined with the QRS complex detection algorithm can provide an important carrier and technical means for the new model of wise information technology of medicine.