Maysam Ghovanloo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Maysam Ghovanloo has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Jia Wang
NC Bionics Laboratory, Department of Electrical and Computer Engineering at NCSU, Raleigh, NC, 27695, USA
2 shared publicationsXueliang Huo
NC Bionics Laboratory, Department of Electrical and Computer Engineering at NCSU, Raleigh, NC 27695, USA
2 shared publications- Amir M. Sodagar
University of Technology, Tehran, Iran
1 shared publication - Anand J. Vasani
Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, USA
1 shared publication K. Najafi
Center for Wireless Integrated Microsystems, Univ. of Michigan, Ann Arbor, MI, USA
1 shared publication- Kensall D. Wise
Fellow, IEEE, Center for Wireless Integrated Microsystems (WIMS), University of Michigan, Ann Arbor, Michigan, 48109, USA
1 shared publication
Latest Publications
- 17 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 15 (3) , 449-457
A Wireless Implantable Multichannel Microstimulating System-on-a-Chip With Modular Architecture
A 64-site wireless current microstimulator chip (Interestim-2B) and a prototype implant based on the same chip have been developed for neural prosthetic applications. Modular standalone architecture allows up to 32 chips to be individually addressed and operated in parallel to drive up to 2048 stimulating sites. The only off-chip components are a receiver inductive-capac- itive (LC) tank, a capacitive low-pass filter for ripple rejection, and arrays of microelectrodes for interfacing with the neural tissue. The implant receives inductive power up to 50 mW and data at 2.5 Mb/s from a frequency shift keyed (FSK) 5/10 MHZ carrier to generate up to 65 800 stimulus pulses/s. Each Interestim-2B chip contains 16 current drivers with 270 muA full-scale current, 5-bit (32-steps) digital-to-analog converter (DAC) resolution, 100 MOmega output impedance, and a voltage compliance that extends within 150 and 250 mV of the 5 V supply and ground rails, respectively. It can generate any arbitrary current waveform and supports a variety of monopolar and bipolar stimulation protocols. A common analog line provides access to each site potential, and exhausts residual stimulus charges for charge balancing. The chip has site potential measurement and in situ site impedance measurement capabilities, which help its users indicate defective sites or characteristic shifts in chronic stimulations. Interestim-2B chip is fabricated in the AMI 1.5 mum standard complementary metal-oxide-semiconductor (CMOS) process and measures 4.6 x 4.6 x 0.5 mm. The prototype implant size including test connectors is 19 X 14 x 6 mm, which can be shrunk down to <0.5 CC. This paper also summarizes some of the in vitro and in vivo experiments performed using the Interestim-2B prototype implant.
- 17 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 15 (3) , 449-457
A Wireless Implantable Multichannel Microstimulating System-on-a-Chip With Modular Architecture
A 64-site wireless current microstimulator chip (Interestim-2B) and a prototype implant based on the same chip have been developed for neural prosthetic applications. Modular standalone architecture allows up to 32 chips to be individually addressed and operated in parallel to drive up to 2048 stimulating sites. The only off-chip components are a receiver inductive-capac- itive (LC) tank, a capacitive low-pass filter for ripple rejection, and arrays of microelectrodes for interfacing with the neural tissue. The implant receives inductive power up to 50 mW and data at 2.5 Mb/s from a frequency shift keyed (FSK) 5/10 MHZ carrier to generate up to 65 800 stimulus pulses/s. Each Interestim-2B chip contains 16 current drivers with 270 muA full-scale current, 5-bit (32-steps) digital-to-analog converter (DAC) resolution, 100 MOmega output impedance, and a voltage compliance that extends within 150 and 250 mV of the 5 V supply and ground rails, respectively. It can generate any arbitrary current waveform and supports a variety of monopolar and bipolar stimulation protocols. A common analog line provides access to each site potential, and exhausts residual stimulus charges for charge balancing. The chip has site potential measurement and in situ site impedance measurement capabilities, which help its users indicate defective sites or characteristic shifts in chronic stimulations. Interestim-2B chip is fabricated in the AMI 1.5 mum standard complementary metal-oxide-semiconductor (CMOS) process and measures 4.6 x 4.6 x 0.5 mm. The prototype implant size including test connectors is 19 X 14 x 6 mm, which can be shrunk down to <0.5 CC. This paper also summarizes some of the in vitro and in vivo experiments performed using the Interestim-2B prototype implant.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 5723-5726
A Wireless Tongue-Computer Interface Using Stereo Differential Magnetic Field Measurement
We have developed an enhanced prototype of the new Tongue Drive system (TDS), which is a noninvasive, unobtrusive wireless magnetic tongue-computer interface for people with severe disabilities. A small permanent magnet secured on the tongue using tissue adhesives, implantation, or piercing is utilized as a tracer to track tongue movements. The magnetic field variations due to the tracer movements are detected by a pair of 3-axial linear magnetic sensor modules mounted bilaterally on a headset near the user's cheeks. The sensors stereo outputs are processed and translated into user control commands after being wirelessly transmitted to a portable computer. These commands have been used in human trials to access the computer by substituting mouse functions. Measurement results showed a response time of less than 1.0 s with 99.9% accuracy for 6 direct commands, yielding an information transfer rate (ITR) of -150 bits/min.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 5723-5726
A Wireless Tongue-Computer Interface Using Stereo Differential Magnetic Field Measurement
We have developed an enhanced prototype of the new Tongue Drive system (TDS), which is a noninvasive, unobtrusive wireless magnetic tongue-computer interface for people with severe disabilities. A small permanent magnet secured on the tongue using tissue adhesives, implantation, or piercing is utilized as a tracer to track tongue movements. The magnetic field variations due to the tracer movements are detected by a pair of 3-axial linear magnetic sensor modules mounted bilaterally on a headset near the user's cheeks. The sensors stereo outputs are processed and translated into user control commands after being wirelessly transmitted to a portable computer. These commands have been used in human trials to access the computer by substituting mouse functions. Measurement results showed a response time of less than 1.0 s with 99.9% accuracy for 6 direct commands, yielding an information transfer rate (ITR) of -150 bits/min.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 97 (1094687X) , 4376-4379
Tongue Operated Assistive Technologies
Assistive technologies help improving the quality of life for severely disabled individuals by enabling them to pursue self-care, educational, vocational, and recreational activities. Tongue has a set of unique characteristics that makes it a suitable appendage for manipulating paralyzed individuals' environments through the use of tongue-operated assistive devices. A number of these devices have been reviewed and a new one, called Tongue Drive, has been introduced.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 97 (1094687X) , 4376-4379
Tongue Operated Assistive Technologies
Assistive technologies help improving the quality of life for severely disabled individuals by enabling them to pursue self-care, educational, vocational, and recreational activities. Tongue has a set of unique characteristics that makes it a suitable appendage for manipulating paralyzed individuals' environments through the use of tongue-operated assistive devices. A number of these devices have been reviewed and a new one, called Tongue Drive, has been introduced.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19483546,p. 322-326
A Magnetic Wireless Tongue-Computer Interface
We have developed a noninvasive, unobtrusive magnetic wireless tongue-computer interface, called "Tongue Drive", to provide people with severe disabilities with flexible and effective computer access and environment control. A small permanent magnet secured on the tongue using a tongue clip, tissue adhesive, or tongue piercing is utilized as a marker to track tongue movements. The magnetic field variations due to the marker movements are detected by an array of magnetic sensors mounted on a headset outside the mouth or an orthodontic brace inside. The sensor outputs are then processed and translated into different user control commands after being wirelessly transmitted to a portable computer (PC or PDA). These commands can be used to access a computer by substituting the mouse or keyboard functions. They can also be customized to operate a powered wheelchair, a phone, or other equipments. For human trials, we have developed a prototype system with 6 direct commands on a baseball helmet and successfully tested it. The Tongue Drive system response time for >95% correctly completed commands is about 1.5 s.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19483546,p. 322-326
A Magnetic Wireless Tongue-Computer Interface
We have developed a noninvasive, unobtrusive magnetic wireless tongue-computer interface, called "Tongue Drive", to provide people with severe disabilities with flexible and effective computer access and environment control. A small permanent magnet secured on the tongue using a tongue clip, tissue adhesive, or tongue piercing is utilized as a marker to track tongue movements. The magnetic field variations due to the marker movements are detected by an array of magnetic sensors mounted on a headset outside the mouth or an orthodontic brace inside. The sensor outputs are then processed and translated into different user control commands after being wirelessly transmitted to a portable computer (PC or PDA). These commands can be used to access a computer by substituting the mouse or keyboard functions. They can also be customized to operate a powered wheelchair, a phone, or other equipments. For human trials, we have developed a prototype system with 6 direct commands on a baseball helmet and successfully tested it. The Tongue Drive system response time for >95% correctly completed commands is about 1.5 s.
- 1 September 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 08865930,p. 659-662
Fully-Integrated CMOS Power Regulator for Telemetry-Powered Implantable Biomedical Microsystems
This paper reports a fully-integrated multi-output CMOS power regulator designed for telemetry-powered implantable microsystems. It is comprised of a CMOS full-wave bridge rectifier, a wide-range multi-output voltage reference and DC level shifter circuits, and three linear voltage regulators. The power regulator fabricated in a 1.5mum standard CMOS process, provides 5V, 3V, and 1.5V regulated outputs, exhibits load regulation factor of as low as 5% when delivering up to 17.3mA load current, and demonstrates line regulation factor of as low as 0.3%/V over 1.8-V input amplitude variation
- 1 September 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 08865930,p. 659-662
Fully-Integrated CMOS Power Regulator for Telemetry-Powered Implantable Biomedical Microsystems
This paper reports a fully-integrated multi-output CMOS power regulator designed for telemetry-powered implantable microsystems. It is comprised of a CMOS full-wave bridge rectifier, a wide-range multi-output voltage reference and DC level shifter circuits, and three linear voltage regulators. The power regulator fabricated in a 1.5mum standard CMOS process, provides 5V, 3V, and 1.5V regulated outputs, exhibits load regulation factor of as low as 5% when delivering up to 17.3mA load current, and demonstrates line regulation factor of as low as 0.3%/V over 1.8-V input amplitude variation
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 566-569
A High-Voltage Output Driver for Implantable Biomedical Stimulators and I/O Applications
This work presents a high voltage output driver stage for implantable microelectronic stimulators implemented in AMI 1.5-μm standard CMOS technology. Stacked device topology is used to implement a high voltage output driver capable of delivering output voltages up to three times the nominal supply voltage. Oxide stress and hot carrier effects are minimized as the voltage across any two terminals of all devices in the output stage are kept below the nominal supply voltage for the utilized technology. Novel techniques are used for level shifting and delay equalization of the complementary inputs to the output driver. The unloaded driver has negligible static power consumption. The output stage is capable of delivering 8.6 V output with a 9 V supply to a 1 kΩ load at an operating frequency of 100 kHz. This corresponds to a driver efficiency of 95.6%. Further improvements and experiments are underway.
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 566-569
A High-Voltage Output Driver for Implantable Biomedical Stimulators and I/O Applications
This work presents a high voltage output driver stage for implantable microelectronic stimulators implemented in AMI 1.5-μm standard CMOS technology. Stacked device topology is used to implement a high voltage output driver capable of delivering output voltages up to three times the nominal supply voltage. Oxide stress and hot carrier effects are minimized as the voltage across any two terminals of all devices in the output stage are kept below the nominal supply voltage for the utilized technology. Novel techniques are used for level shifting and delay equalization of the complementary inputs to the output driver. The unloaded driver has negligible static power consumption. The output stage is capable of delivering 8.6 V output with a 9 V supply to a 1 kΩ load at an operating frequency of 100 kHz. This corresponds to a driver efficiency of 95.6%. Further improvements and experiments are underway.
- 1 May 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 221-224
Finite Element Analysis of Planar Micromachined Silicon Electrodes for Cortical Stimulation
This paper describes a three dimensional (3D) finite element model of micromachined stimulating microelectrode arrays for cortical stimulation. These micromachined probes, known as Michigan probes, are lithographically defined in geometry and fabricated though mostly standard silicon processing technology. However, the fabrication process requires the highly conductive boron-doped shanks, which provide mechanical support for the electrode array, to be grounded especially in active electrodes that incorporate integrated circuits on the same chip. We have examined the effects of grounding this portion (body) of the electrode arrays using finite element analysis (FEA) and drawn a few conclusions about their design. Further, using information gained from our FEA models, we evaluate the current distribution and volume of the excited tissue in a proposed design that would increase the density of electrodes in a given volume and provides greater precision for targeted stimulation
- 1 May 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 221-224
Finite Element Analysis of Planar Micromachined Silicon Electrodes for Cortical Stimulation
This paper describes a three dimensional (3D) finite element model of micromachined stimulating microelectrode arrays for cortical stimulation. These micromachined probes, known as Michigan probes, are lithographically defined in geometry and fabricated though mostly standard silicon processing technology. However, the fabrication process requires the highly conductive boron-doped shanks, which provide mechanical support for the electrode array, to be grounded especially in active electrodes that incorporate integrated circuits on the same chip. We have examined the effects of grounding this portion (body) of the electrode arrays using finite element analysis (FEA) and drawn a few conclusions about their design. Further, using information gained from our FEA models, we evaluate the current distribution and volume of the excited tissue in a proposed design that would increase the density of electrodes in a given volume and provides greater precision for targeted stimulation
- 20 December 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 52 (1) , 97-105
A Compact Large Voltage-Compliance High Output-Impedance Programmable Current Source for Implantable Microstimulators
A new CMOS current source is described for biomedical implantable microstimulator applications, which utilizes MOS transistors in deep triode region as linearized voltage controlled resistors (VCR). The VCR current source achieves large voltage compliance, up to 97% of the supply voltage, while maintaining high output impedance in the 100 M/spl Omega/ range to keep the stimulus current constant within 1% of the desired value irrespective of the site and tissue impedances. This approach improves stimulation efficiency, extends power supply lifetime, and saves chip area especially when the stimulation current level is high in the milliampere range. A prototype 4-channel microstimulator chip is fabricated in the AMI 1.5-/spl mu/m, 2-metal, 2-poly, n-well standard CMOS process. With a 5-V supply, each stimulating site driver provides at least 4.25-V compliance and >10 M/spl Omega/ output impedance, while sinking up to 210 /spl mu/A, and occupies 0.05 mm/sup 2/ in chip area. A modular 32-site wireless neural stimulation microsystem, utilizing the VCR current source, is under development.
- 20 December 2004
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 52 (1) , 97-105
A Compact Large Voltage-Compliance High Output-Impedance Programmable Current Source for Implantable Microstimulators
A new CMOS current source is described for biomedical implantable microstimulator applications, which utilizes MOS transistors in deep triode region as linearized voltage controlled resistors (VCR). The VCR current source achieves large voltage compliance, up to 97% of the supply voltage, while maintaining high output impedance in the 100 M/spl Omega/ range to keep the stimulus current constant within 1% of the desired value irrespective of the site and tissue impedances. This approach improves stimulation efficiency, extends power supply lifetime, and saves chip area especially when the stimulation current level is high in the milliampere range. A prototype 4-channel microstimulator chip is fabricated in the AMI 1.5-/spl mu/m, 2-metal, 2-poly, n-well standard CMOS process. With a 5-V supply, each stimulating site driver provides at least 4.25-V compliance and >10 M/spl Omega/ output impedance, while sinking up to 210 /spl mu/A, and occupies 0.05 mm/sup 2/ in chip area. A modular 32-site wireless neural stimulation microsystem, utilizing the VCR current source, is under development.