Po-Chiun Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Po-Chiun Huang has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Yuan-Hao Huang
Department of Electrical Engineering, Institute of Communications Engineering, National Tsing Hua University, Hsinchu, Taiwan
3 shared publications - Gwo-Bin Lee
Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan
2 shared publications - Hau-Tieng Wu
Courant Institute of Mathematical Sciences, New York University
2 shared publications - Ping-Hsuan Hsieh
Department of Electrical Engineering, National Tsing Hua University, Hsinchu, Taiwan
2 shared publications Chen-Yi Huang
Computer & Communication Laboratories, Industrial Technology and Research Institute
1 shared publicationChi-An Hsu
1 shared publication
Latest Publications
- Open Access
- 21 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Solid-State Circuits Society
- Vol. 5, 454-455
Special Section on Temperature Resilient Systems and Circuits
- 21 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of the Solid-State Circuits Society
- Vol. 5, 454-455
Open AccessSpecial Section on Temperature Resilient Systems and Circuits
- 23 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 57 (10) , 2895-2897
Guest Editorial Introduction to the Special Section on the 2021 Asian Solid-State Circuits Conference (A-SSCC)
The Special Issue of the IEEE Journal of Solid- State Circuits (JSSC) includes some of the highlights of the best papers presented at the 2021 Asian Solid-State Circuits Conference (A-SSCC). This year, the A-SSCC 2021 is held as a hybrid conference on November 7–10, 2021 with attendees having the option to join the in-person meeting in Busan, Korea, or participate virtually through on-line platform. As one of the five conferences fully sponsored by the IEEE Solid-State Circuits Society, the A-SSCC was in its 17th appearance in 2021 since its inauguration in 2005 in Taiwan. Rotating among Asian countries, the A-SSCC is quickly becoming one of the leading global forums for the presentation of advances in solid-state circuits and system-on-a-chip (SoC). From 2021, only two-page format articles are allowed for submission and publication.
- 23 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 57 (10) , 2895-2897
Guest Editorial Introduction to the Special Section on the 2021 Asian Solid-State Circuits Conference (A-SSCC)
The Special Issue of the IEEE Journal of Solid- State Circuits (JSSC) includes some of the highlights of the best papers presented at the 2021 Asian Solid-State Circuits Conference (A-SSCC). This year, the A-SSCC 2021 is held as a hybrid conference on November 7–10, 2021 with attendees having the option to join the in-person meeting in Busan, Korea, or participate virtually through on-line platform. As one of the five conferences fully sponsored by the IEEE Solid-State Circuits Society, the A-SSCC was in its 17th appearance in 2021 since its inauguration in 2005 in Taiwan. Rotating among Asian countries, the A-SSCC is quickly becoming one of the leading global forums for the presentation of advances in solid-state circuits and system-on-a-chip (SoC). From 2021, only two-page format articles are allowed for submission and publication.
- 10 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 5, 138-141
A Cross-Correlation-Based Time-of-Flight Design for Pulsed Chaos Lidar Systems
This work presents an integrated circuit design of a time-of-flight module for pulsed chaos lidar systems. With a mixed-signal architecture and 1-bit digitization, the proposed design evaluates the delay in time and the corresponding distance by calculating the cross-correlation function between the two signals using a 16-unit multiplier-and-integrator array. Tunable filtering further allows resolution and dynamic range scaling. The prototype IC with 90-nm CMOS was evaluated using an in-house pulsed chaos lidar system. At 5 GS/s, experimental results demonstrate a maximum ranging error of 3.38 cm with 1-$\sigma $ of 1.97 cm over a distance of 7.4 m. With the signal pulse width of 100 ns and a repetition period of 50$\mu \text{s}$ , this work consumes 113 mW under a 1-V supply.- 10 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Solid-State Circuits Letters
- Vol. 5, 138-141
A Cross-Correlation-Based Time-of-Flight Design for Pulsed Chaos Lidar Systems
This work presents an integrated circuit design of a time-of-flight module for pulsed chaos lidar systems. With a mixed-signal architecture and 1-bit digitization, the proposed design evaluates the delay in time and the corresponding distance by calculating the cross-correlation function between the two signals using a 16-unit multiplier-and-integrator array. Tunable filtering further allows resolution and dynamic range scaling. The prototype IC with 90-nm CMOS was evaluated using an in-house pulsed chaos lidar system. At 5 GS/s, experimental results demonstrate a maximum ranging error of 3.38 cm with 1-$\sigma $ of 1.97 cm over a distance of 7.4 m. With the signal pulse width of 100 ns and a repetition period of 50$\mu \text{s}$ , this work consumes 113 mW under a 1-V supply.- 19 March 2021
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 25 (4) , 1-12
A miniaturized, DNA-FET biosensor-based microfluidic system for quantification of two breast cancer biomarkers
- 19 March 2021
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 25 (4) , 1-12
A miniaturized, DNA-FET biosensor-based microfluidic system for quantification of two breast cancer biomarkers
- Open Access
- 3 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Nanotechnology
- Vol. 1, 157-162
A CMOS-Based Capacitive Biosensor for Detection of a Breast Cancer MicroRNA Biomarker
Breast cancer ranks among the most common cancers worldwide and can be lethal when not diagnosed early due to the high probability of metastasis. Herein a complementary metal-oxide-semiconductor (CMOS)-based capacitive nano-biosensor was developed to quickly and accurately quantify the concentration of an early-stage breast cancer diagnostic marker, microRNA-195, in blood. The microRNA probe was immobilized on optimized inter-digitated electrodes (IDE), and CMOS-sensing circuits detected the probe-analyte reaction at microRNA-195 concentrations as low as 10 fM. This high sensitivity could be due to the monolithically integrated nature of the circuits, for which “parasitic” effects on the capacitive sensors were markedly low. The CMOS-based capacitive nano-sensor may be promising for early diagnosis of breast cancer.
- 3 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Nanotechnology
- Vol. 1, 157-162
Open AccessA CMOS-Based Capacitive Biosensor for Detection of a Breast Cancer MicroRNA Biomarker
Breast cancer ranks among the most common cancers worldwide and can be lethal when not diagnosed early due to the high probability of metastasis. Herein a complementary metal-oxide-semiconductor (CMOS)-based capacitive nano-biosensor was developed to quickly and accurately quantify the concentration of an early-stage breast cancer diagnostic marker, microRNA-195, in blood. The microRNA probe was immobilized on optimized inter-digitated electrodes (IDE), and CMOS-sensing circuits detected the probe-analyte reaction at microRNA-195 concentrations as low as 10 fM. This high sensitivity could be due to the monolithically integrated nature of the circuits, for which “parasitic” effects on the capacitive sensors were markedly low. The CMOS-based capacitive nano-sensor may be promising for early diagnosis of breast cancer.
- Open Access
Portable Sleep Apnea Syndrome Screening and Event Detection Using Long Short-Term Memory Recurrent Neural Network
Obstructive sleep apnea/hypopnea syndrome (OSAHS) is characterized by repeated airflow partial reduction or complete cessation due to upper airway collapse during sleep. OSAHS can induce frequent awake and intermittent hypoxia that is associated with hypertension and cardiovascular events. Full-channel Polysomnography (PSG) is the gold standard for diagnosing OSAHS; however, this PSG evaluation process is unsuitable for home screening. To solve this problem, a measuring module integrating abdominal and thoracic triaxial accelerometers, a pulsed oximeter (SpO2) and an electrocardiogram sensor was devised in this study. Moreover, a long short-term memory recurrent neural network model is proposed to classify four types of sleep breathing patterns, namely obstructive sleep apnea (OSA), central sleep apnea (CSA), hypopnea (HYP) events and normal breathing (NOR). The proposed algorithm not only reports the apnea-hypopnea index (AHI) through the acquired overnight signals but also identifies the occurrences of OSA, CSA, HYP and NOR, which assists in OSAHS diagnosis. In the clinical experiment with 115 participants, the performances of the proposed system and algorithm were compared with those of traditional expert interpretation based on PSG signals. The accuracy of AHI severity group classification was 89.3%, and the AHI difference for PSG expert interpretation was . The overall accuracy of detecting abnormal OSA, CSA and HYP events was 92.3%.Open AccessPortable Sleep Apnea Syndrome Screening and Event Detection Using Long Short-Term Memory Recurrent Neural Network
Obstructive sleep apnea/hypopnea syndrome (OSAHS) is characterized by repeated airflow partial reduction or complete cessation due to upper airway collapse during sleep. OSAHS can induce frequent awake and intermittent hypoxia that is associated with hypertension and cardiovascular events. Full-channel Polysomnography (PSG) is the gold standard for diagnosing OSAHS; however, this PSG evaluation process is unsuitable for home screening. To solve this problem, a measuring module integrating abdominal and thoracic triaxial accelerometers, a pulsed oximeter (SpO2) and an electrocardiogram sensor was devised in this study. Moreover, a long short-term memory recurrent neural network model is proposed to classify four types of sleep breathing patterns, namely obstructive sleep apnea (OSA), central sleep apnea (CSA), hypopnea (HYP) events and normal breathing (NOR). The proposed algorithm not only reports the apnea-hypopnea index (AHI) through the acquired overnight signals but also identifies the occurrences of OSA, CSA, HYP and NOR, which assists in OSAHS diagnosis. In the clinical experiment with 115 participants, the performances of the proposed system and algorithm were compared with those of traditional expert interpretation based on PSG signals. The accuracy of AHI severity group classification was 89.3%, and the AHI difference for PSG expert interpretation was . The overall accuracy of detecting abnormal OSA, CSA and HYP events was 92.3%. - 28 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 65 (5) , 667-671
Electromagnetic Energy Harvester Interface Design for Wearable Applications
This brief presents an interface design for electromagnetic energy harvesting for wearable applications. A transducer design is proposed. Multiple segments of coils with alternating winding directions improve the induced voltage and power. Due to the source's wideband nature in target applications, we avoid the use of springs common in conventional designs. The corresponding equivalent circuit model is presented. A system-level analysis is then performed that leads to the following power interface circuit design. It includes a differential rectifier and a switched-inductor boost converter. The harvested power is maximized with a constant-resistance load that can be adjusted through a variable-gain amplifier's gain. Implemented in a 0.18-μm CMOS process and tested at 20 Hz, measurement results show 80% impedance matching efficiency with 0.7-V input voltages. The system is able to harvest ~320 μW when shaken by hand at 2.5~3 Hz.
- 28 March 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 65 (5) , 667-671
Electromagnetic Energy Harvester Interface Design for Wearable Applications
This brief presents an interface design for electromagnetic energy harvesting for wearable applications. A transducer design is proposed. Multiple segments of coils with alternating winding directions improve the induced voltage and power. Due to the source's wideband nature in target applications, we avoid the use of springs common in conventional designs. The corresponding equivalent circuit model is presented. A system-level analysis is then performed that leads to the following power interface circuit design. It includes a differential rectifier and a switched-inductor boost converter. The harvested power is maximized with a constant-resistance load that can be adjusted through a variable-gain amplifier's gain. Implemented in a 0.18-μm CMOS process and tested at 20 Hz, measurement results show 80% impedance matching efficiency with 0.7-V input voltages. The system is able to harvest ~320 μW when shaken by hand at 2.5~3 Hz.
- Open Access
Sleep Apnea Detection Based on Thoracic and Abdominal Movement Signals of Wearable Piezo-Electric Bands
Physiologically, the thoracic (THO) and abdominal (ABD) movement signals, captured using wearable piezo-electric bands, provide information about various types of apnea, including central sleep apnea (CSA) and obstructive sleep apnea (OSA). However, the use of piezo-electric wearables in detecting sleep apnea events has been seldom explored in the literature. This study explored the possibility of identifying sleep apnea events, including OSA and CSA, by solely analyzing {one or both the THO and ABD signals. An adaptive non-harmonic model was introduced to model the THO and ABD signals, which allows us to design features for sleep apnea events. To confirm the suitability of the extracted features, a support vector machine was applied to classify three categories -- normal and hypopnea, OSA, and CSA. According to a database of} 34 subjects, the overall classification accuracies were on average $75.9\%\pm 11.7\%$ and $73.8\%\pm 4.4\%$, respectively, based on the cross validation. When the features determined from the THO and ABD signals were combined, the overall classification accuracy became $81.8\%\pm 9.4\%$. These features were applied for designing a state machine for online apnea event detection. Two event-by-event accuracy indices, S and I, were proposed for evaluating the performance {of the state machine. For the same database, the} S index was $84.01\%\pm 9.06\%$, and the I index was $77.21\%\pm 19.01\%$. The results indicate the considerable potential of applying the proposed algorithm to clinical examinations for both screening and homecare purposes.Open AccessSleep Apnea Detection Based on Thoracic and Abdominal Movement Signals of Wearable Piezo-Electric Bands
Physiologically, the thoracic (THO) and abdominal (ABD) movement signals, captured using wearable piezo-electric bands, provide information about various types of apnea, including central sleep apnea (CSA) and obstructive sleep apnea (OSA). However, the use of piezo-electric wearables in detecting sleep apnea events has been seldom explored in the literature. This study explored the possibility of identifying sleep apnea events, including OSA and CSA, by solely analyzing {one or both the THO and ABD signals. An adaptive non-harmonic model was introduced to model the THO and ABD signals, which allows us to design features for sleep apnea events. To confirm the suitability of the extracted features, a support vector machine was applied to classify three categories -- normal and hypopnea, OSA, and CSA. According to a database of} 34 subjects, the overall classification accuracies were on average $75.9\%\pm 11.7\%$ and $73.8\%\pm 4.4\%$, respectively, based on the cross validation. When the features determined from the THO and ABD signals were combined, the overall classification accuracy became $81.8\%\pm 9.4\%$. These features were applied for designing a state machine for online apnea event detection. Two event-by-event accuracy indices, S and I, were proposed for evaluating the performance {of the state machine. For the same database, the} S index was $84.01\%\pm 9.06\%$, and the I index was $77.21\%\pm 19.01\%$. The results indicate the considerable potential of applying the proposed algorithm to clinical examinations for both screening and homecare purposes. - 1 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 392-395
A 0.7-V CMOS operational transconductance amplifier with bulk-driven technique
This paper presents a two-stage pseudo-differential amplifier. Rail-to-rail operations are achieved by using bulk terminals as the inputs. The positive feedback technique is used to enhance the transconductance with negative conductance. The bulk terminals of all transistors are carefully biased to lower their threshold voltages (V th ) and maximize signal swing. Using a standard 0.18-μm CMOS technology, measurement results demonstrate that gain-bandwidth product is 0.97MHz. The settling time for a 0.7-V pp step is 2.1/μS. The input referred noise is 0.14mV at 1MHz. All the circuits dissipate 0.107μW under a single 0.7-V power supply.
- 1 November 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 392-395
A 0.7-V CMOS operational transconductance amplifier with bulk-driven technique
This paper presents a two-stage pseudo-differential amplifier. Rail-to-rail operations are achieved by using bulk terminals as the inputs. The positive feedback technique is used to enhance the transconductance with negative conductance. The bulk terminals of all transistors are carefully biased to lower their threshold voltages (V th ) and maximize signal swing. Using a standard 0.18-μm CMOS technology, measurement results demonstrate that gain-bandwidth product is 0.97MHz. The settling time for a 0.7-V pp step is 2.1/μS. The input referred noise is 0.14mV at 1MHz. All the circuits dissipate 0.107μW under a single 0.7-V power supply.
- 1 January 1995
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Analog and Digital Signal Processing
- Vol. 42 (11) , 745-748
A fully differential CMOS transconductance-transimpedance wideband amplifier
[[abstract]]A high-speed wideband amplifier using a transconductance-transimpedance circuit technique is presented. The proposed circuit configuration results in more reliable performances than are typically obtained from designs using conventional pole-zero, cancellation or peaking technique. With a 0.8 μm, double poly, double metal, n-well CMOS technology and single 5-V power supply, the prelayout simulation of this amplifier shows a -3 dB frequency of 300 MHz with a voltage gain of 14 dB when the loading capacitance is 1.5 pF[[fileno]]2030155010009[[department]]電機工程
- 1 January 1995
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Analog and Digital Signal Processing
- Vol. 42 (11) , 745-748
A fully differential CMOS transconductance-transimpedance wideband amplifier
[[abstract]]A high-speed wideband amplifier using a transconductance-transimpedance circuit technique is presented. The proposed circuit configuration results in more reliable performances than are typically obtained from designs using conventional pole-zero, cancellation or peaking technique. With a 0.8 μm, double poly, double metal, n-well CMOS technology and single 5-V power supply, the prelayout simulation of this amplifier shows a -3 dB frequency of 300 MHz with a voltage gain of 14 dB when the loading capacitance is 1.5 pF[[fileno]]2030155010009[[department]]電機工程