Young June Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Young June Park has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
Seok Hyang Kim
Seoul National University 1 Department of Electrical and Computer Engineering Seoul 151-744, South Korea
5 shared publicationsSung Min Seo
School of Electrical Engineering & Computer Science, and the Nano-Systems Institute-National Core Research Center, Seoul National University, Gwanak-ro 599, Gwanak-gu, Seoul 151-742, South Korea
5 shared publications- Hong Shick Min4 shared publications
Jun Ho Cheon
School of Electrical Engineering, Seoul National University , Seoul 151-742 , Republic of Korea ; NanoSystems Institute, Seoul National University , Seoul 151-742 , Republic of Korea
4 shared publicationsChang-Ki Baek
Department of Electronic and Electrical Engineering, Pohang University of Science and Technology (POSTECH), Pohang 790-784, Korea
3 shared publications- Geon Kim
Department of ICT Convergence System Engineering, Chonnam National University, Gwangju 61186, Korea
3 shared publications
Latest Publications
- Open Access
Improvement in Variational Quantum Algorithms by Measurement Simplification
Variational Quantum Algorithms (VQAs) are expected to be promising algorithms with quantum advantages that can be run at quantum computers in the close future. In this work, we review simple rules in basic quantum circuits, and propose a simplification method, Measurement Simplification, that simplifies the expression for the measurement of quantum circuit. By the Measurement Simplification, we simplified the specific result expression of VQAs and obtained large improvements in calculation time and required memory size. Here we applied Measurement Simplification to Variational Quantum Linear Solver (VQLS), Variational Quantum Eigensolver (VQE) and other Quantum Machine Learning Algorithms to show an example of speedup in the calculation time and required memory size.
Open AccessImprovement in Variational Quantum Algorithms by Measurement Simplification
Variational Quantum Algorithms (VQAs) are expected to be promising algorithms with quantum advantages that can be run at quantum computers in the close future. In this work, we review simple rules in basic quantum circuits, and propose a simplification method, Measurement Simplification, that simplifies the expression for the measurement of quantum circuit. By the Measurement Simplification, we simplified the specific result expression of VQAs and obtained large improvements in calculation time and required memory size. Here we applied Measurement Simplification to Variational Quantum Linear Solver (VQLS), Variational Quantum Eigensolver (VQE) and other Quantum Machine Learning Algorithms to show an example of speedup in the calculation time and required memory size.
- Open Access
- 21 December 2018
- Published by MDPI AG in Electronics
- Vol. 8 (1) , 8
Partial Isolation Type Saddle-FinFET(Pi-FinFET) for Sub-30 nm DRAM Cell Transistors
In this paper, we proposed a novel saddle type FinFET (S-FinFET) to effectively solve problems occurring under the capacitor node of a dynamic random-access memory (DRAM) cell and showed how its structure was superior to conventional S-FinFETs in terms of short channel effect (SCE), subthreshold slope (SS), and gate-induced drain leakage (GIDL). The proposed FinFET exhibited four times lower Ioff than modified S-FinFET, called RFinFET, with more improved drain-induced barrier lowering (DIBL) characteristics, while minimizing Ion reduction compared to RFinFET. Our results also confirmed that the proposed device showed improved drain-induced barrier lowering (DIBL) and Ioff characteristics as gate channel length decreased.
- 21 December 2018
- Published by MDPI AG in Electronics
- Vol. 8 (1) , 8
Open AccessPartial Isolation Type Saddle-FinFET(Pi-FinFET) for Sub-30 nm DRAM Cell Transistors
In this paper, we proposed a novel saddle type FinFET (S-FinFET) to effectively solve problems occurring under the capacitor node of a dynamic random-access memory (DRAM) cell and showed how its structure was superior to conventional S-FinFETs in terms of short channel effect (SCE), subthreshold slope (SS), and gate-induced drain leakage (GIDL). The proposed FinFET exhibited four times lower Ioff than modified S-FinFET, called RFinFET, with more improved drain-induced barrier lowering (DIBL) characteristics, while minimizing Ion reduction compared to RFinFET. Our results also confirmed that the proposed device showed improved drain-induced barrier lowering (DIBL) and Ioff characteristics as gate channel length decreased.
- Open Access
- 2 November 2018
- Published by MDPI AG in Preprints.org
Partial Isolation Type Saddle-FinFET(Pi-FinFET) for Sub-30 nm DRAM Cell Transistors
In this paper, we proposed a novel saddle type FinFET (S-FinFET) to effectively solve problems occurring under the capacitor node of dynamic random-access memory (DRAM) cell and showed how its structure was superior to conventional S-FinFETs in terms of short channel effect (SCE), subthreshold slope (SS), and gate-induced drain leakage (GIDL). The proposed FinFET exhibited 4 times lower Ioff than modified S-FinFET called RFinFET with more improved DIBL characteristics while minimizing Ion reduction compared to RFinFET. Our results also confirmed that the proposed device showed improved DIBL and Ioff characteristics as gate channel length decreased.
- 2 November 2018
- Published by MDPI AG in Preprints.org
Open AccessPartial Isolation Type Saddle-FinFET(Pi-FinFET) for Sub-30 nm DRAM Cell Transistors
In this paper, we proposed a novel saddle type FinFET (S-FinFET) to effectively solve problems occurring under the capacitor node of dynamic random-access memory (DRAM) cell and showed how its structure was superior to conventional S-FinFETs in terms of short channel effect (SCE), subthreshold slope (SS), and gate-induced drain leakage (GIDL). The proposed FinFET exhibited 4 times lower Ioff than modified S-FinFET called RFinFET with more improved DIBL characteristics while minimizing Ion reduction compared to RFinFET. Our results also confirmed that the proposed device showed improved DIBL and Ioff characteristics as gate channel length decreased.
- Open Access
- 2 October 2018
- Published by MDPI AG in Electronics
- Vol. 7 (10) , 227
Simulation Analysis in Sub-0.1 μm for Partial Isolation Field-Effect Transistors
In this paper, we extensively analyzed the drain-induced barrier lowering (DIBL) and leakage current characteristics of the proposed partial isolation field-effect transistor (PiFET) structure. We then compared the PiFET with the conventional planar metal-oxide semiconductor field-effect transistor (MOSFET) and silicon on insulator (SOI) structures, even though they have the same doping profile. Two major features of the PiFET are potential condensation and potential modulation by a buried insulator. The potential modulation near the drain region can control the electric field in the overlapped region of the drain and gate, because it causes a high gate-fringing field. Therefore, we suggest guidelines with respect to the optimal PiFET structure.
- 2 October 2018
- Published by MDPI AG in Electronics
- Vol. 7 (10) , 227
Open AccessSimulation Analysis in Sub-0.1 μm for Partial Isolation Field-Effect Transistors
In this paper, we extensively analyzed the drain-induced barrier lowering (DIBL) and leakage current characteristics of the proposed partial isolation field-effect transistor (PiFET) structure. We then compared the PiFET with the conventional planar metal-oxide semiconductor field-effect transistor (MOSFET) and silicon on insulator (SOI) structures, even though they have the same doping profile. Two major features of the PiFET are potential condensation and potential modulation by a buried insulator. The potential modulation near the drain region can control the electric field in the overlapped region of the drain and gate, because it causes a high gate-fringing field. Therefore, we suggest guidelines with respect to the optimal PiFET structure.
- 27 March 2018
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 123 (12) , 124902
Featuring of transient tunneling current by voltage pulse and application to an electrochemical biosensor
We suggest a voltage pulse method for detecting the transient tunneling current component (faradaic current component) in a metal/redox-active monolayer/electrolyte system. After applying the pulse to the metal electrode, the capacitive current prevails; therefore, it is difficult to extract the tunneling current, which carries information on the biochemical reactions occurring between the biomarkers in the electrolyte and the self-assembled monolayer (SAM) as the probe peptide system. Instead of waiting until the capacitive current diminishes, and thereby, the tunneling current also decreases, we try to extract the tunneling current in an early stage of the pulse. The method is based on the observation that the capacitive current becomes symmetrized in the positive and negative pulses after introducing the SAM on the metal electrode. When the energy level of the redox molecule is higher than the Fermi level of the metal under zero-bias condition, the tunneling current in the negative pulse can be extracted by subtracting the capacitive current obtained from the positive pulse, where the tunneling current is neglected. The experiment conducted for detecting trypsin as a biomarker shows that the method enhances the sensitivity and the specific-to-nonspecific ratio of the sensor device in the case of the nonspecific protein-abundant electrolyte solution, as evinced by cyclic voltammetry measurements in comparison.
- 27 March 2018
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 123 (12) , 124902
Featuring of transient tunneling current by voltage pulse and application to an electrochemical biosensor
We suggest a voltage pulse method for detecting the transient tunneling current component (faradaic current component) in a metal/redox-active monolayer/electrolyte system. After applying the pulse to the metal electrode, the capacitive current prevails; therefore, it is difficult to extract the tunneling current, which carries information on the biochemical reactions occurring between the biomarkers in the electrolyte and the self-assembled monolayer (SAM) as the probe peptide system. Instead of waiting until the capacitive current diminishes, and thereby, the tunneling current also decreases, we try to extract the tunneling current in an early stage of the pulse. The method is based on the observation that the capacitive current becomes symmetrized in the positive and negative pulses after introducing the SAM on the metal electrode. When the energy level of the redox molecule is higher than the Fermi level of the metal under zero-bias condition, the tunneling current in the negative pulse can be extracted by subtracting the capacitive current obtained from the positive pulse, where the tunneling current is neglected. The experiment conducted for detecting trypsin as a biomarker shows that the method enhances the sensitivity and the specific-to-nonspecific ratio of the sensor device in the case of the nonspecific protein-abundant electrolyte solution, as evinced by cyclic voltammetry measurements in comparison.
- 12 January 2018
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 123 (2)
A theoretical study on tunneling based biosensor having a redox-active monolayer using physics based simulation
We developed a numerical simulator to model the operation of a tunneling based biosensor which has a redox-active monolayer. The simulator takes a realistic device structure as a simulation domain, and it employs the drift-diffusion equation for ion transport, the non-equilibrium Green's function formalism for electron tunneling, and the Ramo-Shockley theorem for accurate calculation of non-faradaic current. We also accounted for the buffer reaction and the immobilized peptide layer. For efficient transient simulation, the implicit time integration scheme is employed where the solution at each time step is obtained from the coupled Newton-Raphson method. As an application, we studied the operation of a recently fabricated reference-electrode free biosensor in various bias conditions and confirmed the effect of buffer reaction and the current flowing mechanism. Using the simulator, we also found a strategy to maximize the sensitivity of the tunneling based sensor.
- 12 January 2018
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 123 (2)
A theoretical study on tunneling based biosensor having a redox-active monolayer using physics based simulation
We developed a numerical simulator to model the operation of a tunneling based biosensor which has a redox-active monolayer. The simulator takes a realistic device structure as a simulation domain, and it employs the drift-diffusion equation for ion transport, the non-equilibrium Green's function formalism for electron tunneling, and the Ramo-Shockley theorem for accurate calculation of non-faradaic current. We also accounted for the buffer reaction and the immobilized peptide layer. For efficient transient simulation, the implicit time integration scheme is employed where the solution at each time step is obtained from the coupled Newton-Raphson method. As an application, we studied the operation of a recently fabricated reference-electrode free biosensor in various bias conditions and confirmed the effect of buffer reaction and the current flowing mechanism. Using the simulator, we also found a strategy to maximize the sensitivity of the tunneling based sensor.
- 28 November 2016
- Published by AIP Publishing in Applied Physics Letters
- Vol. 109 (22) , 223701
An effective electrical sensing scheme using AC electrothermal flow on a biosensor platform based on a carbon nanotube network
We report a simple and efficient electrical sensing scheme that can be used to overcome the “diffusion limit” of affinity-based biosensors by incorporating the structural advantage of a concentric electrode biosensor platform and the microstirring effect of AC electrothermal flow (ACEF). To prove the effect of ACEF on the biosensor performance, we performed both simulations and experiments for the detection of cardiac troponin-I, which is a biomarker for acute myocardial infarction. The finite element simulation results indicate that AC bias to the electrode (which has a concentric structure in our device) can induce fast convection flow, which facilitates the transport of the target molecules to the binding region located between the two electrodes. In our device, the channel region made of a carbon nanotube network decorated with gold nanoparticles, which act as the attaching sites of the probe molecules, is used as a highly sensitive electrical channel. We find that the electrical sensing method exhibited extremely fast sensing speeds compared with those under no bias (diffusion-limited) conditions.
- 28 November 2016
- Published by AIP Publishing in Applied Physics Letters
- Vol. 109 (22) , 223701
An effective electrical sensing scheme using AC electrothermal flow on a biosensor platform based on a carbon nanotube network
We report a simple and efficient electrical sensing scheme that can be used to overcome the “diffusion limit” of affinity-based biosensors by incorporating the structural advantage of a concentric electrode biosensor platform and the microstirring effect of AC electrothermal flow (ACEF). To prove the effect of ACEF on the biosensor performance, we performed both simulations and experiments for the detection of cardiac troponin-I, which is a biomarker for acute myocardial infarction. The finite element simulation results indicate that AC bias to the electrode (which has a concentric structure in our device) can induce fast convection flow, which facilitates the transport of the target molecules to the binding region located between the two electrodes. In our device, the channel region made of a carbon nanotube network decorated with gold nanoparticles, which act as the attaching sites of the probe molecules, is used as a highly sensitive electrical channel. We find that the electrical sensing method exhibited extremely fast sensing speeds compared with those under no bias (diffusion-limited) conditions.
- 23 July 2015
- Published by Springer Nature
- p. 3-18
A CNT Network Platform Integrated on the CMOS Circuit
- 23 July 2015
- Published by Springer Nature
- p. 3-18
A CNT Network Platform Integrated on the CMOS Circuit
- 29 June 2015
- Published by AIP Publishing in Applied Physics Letters
- Vol. 106 (26) , 263701
Electrical passivation of nonselective bio molecules in carbon nanotubes: Effect of pulse train in serum
We present an experimental and simulation study about a desorption of albumin, a representative nonselective molecules in serum, on carbon nanotube (CNT) surface as an electrical bio sensing channel under the pulse train condition. The motivation of the study on binding kinetics between CNT surface and albumin is to suppress the adsorption of nonselective proteins in blood such as albumin, thereby enhancing the selectivity of the electrical biosensor. To theoretically model the behavior of molecules and ions under the step pulse bias, the physics on the reaction rate, mass transport, and the resulting surface pH-value are considered using the Poisson and drift-diffusion equations. For the simulation model, the phosphate buffered saline is considered as the electrolyte solution and albumin is considered as a representative charged molecule for nonspecific binding in serum. Both the transient simulation and experimental result indicate that the suppression of the nonspecific binding under the pulse train is due to the unsymmetrical field force experienced by the protein during the pulse transitions (high to low and low to high) and the non-symmetry is caused by the different transient times between the electric field and the charge/discharge of the protein according to the surface pH modulation in serum. The experimental and simulation results clearly indicate that the pulse bias suppresses the nonselective bio molecules adsorption at the CNT surface so that the selectivity of the electrical biosensor for detecting the target molecules can be enhanced.
- 29 June 2015
- Published by AIP Publishing in Applied Physics Letters
- Vol. 106 (26) , 263701
Electrical passivation of nonselective bio molecules in carbon nanotubes: Effect of pulse train in serum
We present an experimental and simulation study about a desorption of albumin, a representative nonselective molecules in serum, on carbon nanotube (CNT) surface as an electrical bio sensing channel under the pulse train condition. The motivation of the study on binding kinetics between CNT surface and albumin is to suppress the adsorption of nonselective proteins in blood such as albumin, thereby enhancing the selectivity of the electrical biosensor. To theoretically model the behavior of molecules and ions under the step pulse bias, the physics on the reaction rate, mass transport, and the resulting surface pH-value are considered using the Poisson and drift-diffusion equations. For the simulation model, the phosphate buffered saline is considered as the electrolyte solution and albumin is considered as a representative charged molecule for nonspecific binding in serum. Both the transient simulation and experimental result indicate that the suppression of the nonspecific binding under the pulse train is due to the unsymmetrical field force experienced by the protein during the pulse transitions (high to low and low to high) and the non-symmetry is caused by the different transient times between the electric field and the charge/discharge of the protein according to the surface pH modulation in serum. The experimental and simulation results clearly indicate that the pulse bias suppresses the nonselective bio molecules adsorption at the CNT surface so that the selectivity of the electrical biosensor for detecting the target molecules can be enhanced.
- 1 January 2015
- Published by Springer Nature
- p. 3-23
“C-chip” Platform for Electrical Biomolecular Sensors
- 1 January 2015
- Published by Springer Nature
- p. 3-23
“C-chip” Platform for Electrical Biomolecular Sensors