DHDavid Holmes

David Holmes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


David Holmes has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Leukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometry

    by David Holmes, David Pettigrew, Christian H. Reccius, James D. Gwyer, Cees van Berkel, Judith Holloway, Donna E. Davies, Hywel Morgan

    Miniature high speed label-free cell analysis systems have yet to be developed, but have the potential to deliver fast, inexpensive and simple full blood cell analysis systems that could be used routinely in clinical practice. We demonstrate a microfluidic single cell impedance cytometer that performs a white blood cell differential count. The device consists of a microfluidic chip with micro-electrodes that measure the impedance of single cells at two frequencies. Human blood, treated with saponin/formic acid to lyse erythrocytes, flows through the device and a complete blood count is performed in a few minutes. Verification of cell dielectric parameters was performed by simultaneously measuring fluorescence from CD antibody-conjugated cells. This enabled direct correlation of impedance signals from individual cells with phenotype. Tests with patient samples showed 95% correlation against commercial (optical/Coulter) blood analysis equipment, demonstrating the potential clinical utility of the impedance microcytometer for a point-of-care blood analysis system.


  • Bead-based immunoassays using a micro-chip flow cytometer

    by David Holmes, Joseph K. She, Peter L. Roach, Hywel Morgan

    A microfabricated flow cytometer has been developed for the analysis of micron-sized polymer beads onto which fluorescently labelled proteins have been immobilised. Fluorescence measurements were made on the beads as they flowed through the chip. Binding of antibodies to surface-immobilised antigens was quantitatively assayed using the device. Particles were focused through a detection zone in the centre of the flow channel using negative dielectrophoresis. Impedance measurements of the particles (at 703 kHz) were used to determine particle size and to trigger capture of the fluorescence signal. Antibody binding was measured by fluorescence at single and dual excitation wavelengths (532 nm and 633 nm). Fluorescence compensation techniques were implemented to correct for spectral overspill between optical detection channels. The data from the microfabricated flow cytometer was shown to be comparable to that of a commercial flow cytometer (BD-FACSAria).


  • Label-Free Differential Leukocyte Counts Using a Microfabricated, Single-Cell Impedance Spectrometer

    by David Holmes, Tao Sun, Hywel Morgan, Judith Holloway, Julie Cakebread, Donna Davies

    Impedance spectroscopy is a non-invasive technique which allows analysis of the electrical properties of biological cells and other materials. Typically, the electrical properties of a cell suspension are measured using relatively large volumes (>100 mul). This approach suffers from the significant drawback that the measurement is averaged over several million cells, and as such, discrimination of cell sub-population and cell sorting is impossible. We have developed a microfluidic device capable of high-speed impedance analysis of individual cells in rapid succession. In this paper, we outline the theory for impedance analysis of a single cell in a microchip. We show experimentally, the ability of the technology to distinguish, based on impedance alone, the three main leukocyte (white blood cell) sub-populations (monocytes, lymphocytes, neutrophils) in human blood. Fluorescence analysis of the cells is performed simultaneously with impedance measurement, as cells flow through the device. This provides a direct correlation between cell type (based on antibody) and impedance properties. The data shows distinct differences in the impedance properties of leukocyte sub-populations at specific frequencies.


  • Micro System Technology for Marine Measurement

    by Matt Mowlem, Valerie Chavagnac, Peter Statham, Peter Burkill, Giuseppe Benazzi, David Holmes, Hywel Morgan, Christoph Haas, Michael Kraft, Alan Taberham

    To date the development of in situ chemical and biological sensors has focused on the production of macro instruments for single point deployment. With the exception of oxygen sensors and biological sensors based on fluorometry (that are now commercially available) chemical and biological sensors are not able to make repeated synoptic measurements at finer temporal and spatial scales. This is at odds with the patchiness and temporal variability observed in biogeochemical processes. This paper describes the early stages of development of miniature and mass producible chemical and biological sensors using Micro System Technology. It is hoped that these devices will be suitable for mass deployment and will deliver repeated synoptic data that will allow greater understanding and improved modelling of biogeochemical processes. Initially the production of two devices has been targeted: 1) A miniature cytometer to count and speciate phytoplankton; and 2) A lab-on-a-chip analyser using wet chemistry and optical detection. The production of the analysis chip for the cytometer and a micropump suitable for the lab-on-a-chip analyser are presented here. Preliminary investigations of biofouling are also discussed