Fredrik Lingvall
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fredrik Lingvall has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Tadeusz Stepinski
AGH University of Science and Technology
1 shared publication Tomas Olofsson
Signals and Systems Group, Department of Material Science, Uppsala University, Box 528, 751 20 Uppsala, Sweden
1 shared publication
Latest Publications
- 1 April 2004
- Published by Elsevier in Ultrasonics
- Vol. 42 (1-9) , 961-968
A method of improving overall resolution in ultrasonic array imaging using spatio-temporal deconvolution
- 1 April 2004
- Published by Elsevier in Ultrasonics
- Vol. 42 (1-9) , 961-968
A method of improving overall resolution in ultrasonic array imaging using spatio-temporal deconvolution
- 1 July 2003
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 114 (1) , 225-234
Synthetic aperture imaging using sources with finite aperture: Deconvolution of the spatial impulse response
A method for ultrasonic synthetic aperture imaging using finite-sized transducers is introduced that is based on a compact, linear, discrete model of the ultrasonic measurement system developed using matrix formalism. Using this model a time-domain algorithm for deconvolution of the transducer’s spatial impulse responses (SIRs) is developed that is based on a minimum mean square error (MMSE) criterion. The algorithm takes the form of a spatiotemporal filter that compensates for the SIRs associated with a finite-sized transducer at every point of the processed image. A major advantage of the proposed method is that it can be used for any transducer, provided that its associated SIRs are known. This is in contrast to the synthetic aperture focusing technique (SAFT), which treats the transducer as a point source. The performance of the method is evaluated with simulations and experiments, performed in water using a linear phased array. The results obtained using the proposed method are compared to those obtained with a classical time-domain SAFT algorithm. For a finite aperture source, it is clearly shown that the resolution obtained using the proposed method is superior to that obtained using the SAFT algorithm.
- 1 July 2003
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 114 (1) , 225-234
Synthetic aperture imaging using sources with finite aperture: Deconvolution of the spatial impulse response
A method for ultrasonic synthetic aperture imaging using finite-sized transducers is introduced that is based on a compact, linear, discrete model of the ultrasonic measurement system developed using matrix formalism. Using this model a time-domain algorithm for deconvolution of the transducer’s spatial impulse responses (SIRs) is developed that is based on a minimum mean square error (MMSE) criterion. The algorithm takes the form of a spatiotemporal filter that compensates for the SIRs associated with a finite-sized transducer at every point of the processed image. A major advantage of the proposed method is that it can be used for any transducer, provided that its associated SIRs are known. This is in contrast to the synthetic aperture focusing technique (SAFT), which treats the transducer as a point source. The performance of the method is evaluated with simulations and experiments, performed in water using a linear phased array. The results obtained using the proposed method are compared to those obtained with a classical time-domain SAFT algorithm. For a finite aperture source, it is clearly shown that the resolution obtained using the proposed method is superior to that obtained using the SAFT algorithm.