Yiting Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yiting Xie has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Alberto M. Biancardi
Cornell University
1 shared publication - Anthony P. Reeves
Cornell University, School of Electrical and Computer Engineering, Ithaca, New York, United States
1 shared publication - Anthony P. Reeves
Department of Electrical and Computer Engineering, Cornell University, Ithaca, NY
1 shared publication - Artit Jirapatnakul
Department of Diagnostic, Molecular, and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, New York 10029
1 shared publication - Jennifer Padgett
Cornell University
1 shared publication
Latest Publications
- 30 June 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (1) , 73-88
Automated pulmonary nodule CT image characterization in lung cancer screening
Purpose In lung cancer screening, pulmonary nodules are first identified in low-dose chest CT images. Costly follow-up procedures could be avoided if it were possible to establish the malignancy status of these nodules from these initial images. Preliminary computer methods have been proposed to characterize the malignancy status of pulmonary nodules based on features extracted from a CT image. The parameters and performance of such a computer system in a lung cancer screening context are addressed. Methods A computer system that incorporates novel 3D image features to determine the malignancy status of pulmonary nodules is evaluated with a large dataset constructed from images from the NLST and ELCAP lung cancer studies. The system is evaluated with different data subsets to determine the impact of class size distribution imbalance in datasets and to evaluate different training and testing strategies. Results Results show a modest improvement in malignancy prediction compared to prediction by size alone for a traditional size-unbalanced dataset. Further, the advantage of size binning for classifier design and the advantages of a size-balanced dataset for both training and testing are demonstrated. Conclusion Nodule classification in the context of low-resolution low-dose whole-chest CT images for the clinically relevant size range in the context of lung cancer screening is highly challenging, and results are moderate compared to what has been reported in the literature for other clinical contexts. Nodule class size distribution imbalance needs to be considered in the training and evaluation of computer-aided diagnostic systems for producing patient-relevant outcomes.
- 30 June 2015
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 11 (1) , 73-88
Automated pulmonary nodule CT image characterization in lung cancer screening
Purpose In lung cancer screening, pulmonary nodules are first identified in low-dose chest CT images. Costly follow-up procedures could be avoided if it were possible to establish the malignancy status of these nodules from these initial images. Preliminary computer methods have been proposed to characterize the malignancy status of pulmonary nodules based on features extracted from a CT image. The parameters and performance of such a computer system in a lung cancer screening context are addressed. Methods A computer system that incorporates novel 3D image features to determine the malignancy status of pulmonary nodules is evaluated with a large dataset constructed from images from the NLST and ELCAP lung cancer studies. The system is evaluated with different data subsets to determine the impact of class size distribution imbalance in datasets and to evaluate different training and testing strategies. Results Results show a modest improvement in malignancy prediction compared to prediction by size alone for a traditional size-unbalanced dataset. Further, the advantage of size binning for classifier design and the advantages of a size-balanced dataset for both training and testing are demonstrated. Conclusion Nodule classification in the context of low-resolution low-dose whole-chest CT images for the clinically relevant size range in the context of lung cancer screening is highly challenging, and results are moderate compared to what has been reported in the literature for other clinical contexts. Nodule class size distribution imbalance needs to be considered in the training and evaluation of computer-aided diagnostic systems for producing patient-relevant outcomes.
- 23 July 2013
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 9 (2) , 211-219
Automated aorta segmentation in low-dose chest CT images
Abnormalities of aortic surface and aortic diameter can be related to cardiovascular disease and aortic aneurysm. Computer-based aortic segmentation and measurement may aid physicians in related disease diagnosis. This paper presents a fully automated algorithm for aorta segmentation in low-dose non-contrast CT images. The original non-contrast CT scan images as well as their pre-computed anatomy label maps are used to locate the aorta and identify its surface. First a seed point is located inside the aortic lumen. Then, a cylindrical model is progressively fitted to the 3D image space to track the aorta centerline. Finally, the aortic surface is located based on image intensity information. This algorithm has been trained and tested on 359 low-dose non-contrast CT images from VIA-ELCAP and LIDC public image databases. Twenty images were used for training to obtain the optimal set of parameters, while the remaining images were used for testing. The segmentation result has been evaluated both qualitatively and quantitatively. Sixty representative testing images were used to establish a partial ground truth by manual marking on several axial image slices. Compared to ground truth marking, the segmentation result had a mean Dice Similarity Coefficient of 0.933 (maximum 0.963 and minimum 0.907). The average boundary distance between manual segmentation and automatic segmentation was 1.39 mm with a maximum of 1.79 mm and a minimum of 0.83 mm. Both qualitative and quantitative evaluations have shown that the presented algorithm is able to accurately segment the aorta in low-dose non-contrast CT images.
- 23 July 2013
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 9 (2) , 211-219
Automated aorta segmentation in low-dose chest CT images
Abnormalities of aortic surface and aortic diameter can be related to cardiovascular disease and aortic aneurysm. Computer-based aortic segmentation and measurement may aid physicians in related disease diagnosis. This paper presents a fully automated algorithm for aorta segmentation in low-dose non-contrast CT images. The original non-contrast CT scan images as well as their pre-computed anatomy label maps are used to locate the aorta and identify its surface. First a seed point is located inside the aortic lumen. Then, a cylindrical model is progressively fitted to the 3D image space to track the aorta centerline. Finally, the aortic surface is located based on image intensity information. This algorithm has been trained and tested on 359 low-dose non-contrast CT images from VIA-ELCAP and LIDC public image databases. Twenty images were used for training to obtain the optimal set of parameters, while the remaining images were used for testing. The segmentation result has been evaluated both qualitatively and quantitatively. Sixty representative testing images were used to establish a partial ground truth by manual marking on several axial image slices. Compared to ground truth marking, the segmentation result had a mean Dice Similarity Coefficient of 0.933 (maximum 0.963 and minimum 0.907). The average boundary distance between manual segmentation and automatic segmentation was 1.39 mm with a maximum of 1.79 mm and a minimum of 0.83 mm. Both qualitative and quantitative evaluations have shown that the presented algorithm is able to accurately segment the aorta in low-dose non-contrast CT images.