Michael Tchirikov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Michael Tchirikov has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Gene B. Hubbard
Department of Comparative Medicine and Southwest National Primate Research Center at the Southwest Foundation for Biomedical Research, San Antonio, TX, USA
2 shared publicationsH. J. Schröder
Department of Experimental Feto‐Maternal Medicine, University Medical Center Hamburg‐Eppendorf, Germany
2 shared publicationsHobe J. Schröder
Department of Obstetrics and Fetal Medicine, University Medical Centre Hamburg‐Eppendorf, Hamburg, Germany
2 shared publications- Natalia Schlabritz-Loutsevitch
Department of Obstetrics and Gynecology, College of Medicine, Texas Tech University Health Sciences Center at the Permian Basin, Odessa, TX, USA
2 shared publications - Peter W. Nathanielsz
Texas Pregnancy and Life-course Health Research Center, Department of Animal Science, University of Wyoming
2 shared publications B. Hüneke
Universitätsklinikum Hamburg‐Eppendorf, Klinik für Frauenheilkunde und Geburtshilfe, Hamburg, Germany
1 shared publication
Latest Publications
- 24 March 2006
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 27 (4) , 452-461
Ductus venosus shunting in the fetal venous circulation: regulatory mechanisms, diagnostic methods and medical importance
The fetal liver is located at the crossroads of the umbilical venous circulation. Anatomically, the ductus venosus (DV) and the intrahepatic branches of the portal vein are arranged in parallel. The actual DV shunting rate, i.e. the percentage of umbilical blood flow entering the DV measured by Doppler velocimetry, seems to be lower than that estimated using radioactively‐labeled microspheres. In human fetuses the DV shunting rate is about 20–30%. Increases in the DV shunting rate are a general adaptational mechanism to fetal distress. Hypoxia results in a significant increase in the DV shunting rate, most probably in order to ensure an adequate supply of oxygen and glucose to vitally important organs such as the brain and heart. The mechanism of blood flow redistribution between the fetal liver and the DV is still a matter of debate. The isthmic portion of the DV contains less smooth muscle tissue than the intrahepatic branches of the portal vein, which in vitro react more forcefully in response to catecholamines than the DV.In growth‐restricted human fetuses DV shunting is increased and the umbilical blood supply to the fetal liver is reduced. The long‐term reduction of the hepatic blood supply may be involved in fetal growth restriction. The occlusion of the DV leads to a significant increase in cell proliferation in fetal skeletal muscle, heart, kidneys and liver, and possibly to an increase in insulin‐like growth factor (IGF)‐I and ‐II mRNA expression in the fetal liver. These findings hint at the possible role of the perfusion of the fetal liver in the control of the growth process.The quantification of DV shunting by Doppler velocimetry may improve the early recognition of fetal compromise in prenatal medicine. In this Review we summarize the published data on the anatomical structure and histology of the DV, the mechanisms of regulation of DV shunting, its role in fetal survival and growth and the possible use of the measurement of DV shunting in clinical practice. Copyright © 2006 ISUOG. Published by John Wiley & Sons, Ltd.
- 24 March 2006
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 27 (4) , 452-461
Ductus venosus shunting in the fetal venous circulation: regulatory mechanisms, diagnostic methods and medical importance
The fetal liver is located at the crossroads of the umbilical venous circulation. Anatomically, the ductus venosus (DV) and the intrahepatic branches of the portal vein are arranged in parallel. The actual DV shunting rate, i.e. the percentage of umbilical blood flow entering the DV measured by Doppler velocimetry, seems to be lower than that estimated using radioactively‐labeled microspheres. In human fetuses the DV shunting rate is about 20–30%. Increases in the DV shunting rate are a general adaptational mechanism to fetal distress. Hypoxia results in a significant increase in the DV shunting rate, most probably in order to ensure an adequate supply of oxygen and glucose to vitally important organs such as the brain and heart. The mechanism of blood flow redistribution between the fetal liver and the DV is still a matter of debate. The isthmic portion of the DV contains less smooth muscle tissue than the intrahepatic branches of the portal vein, which in vitro react more forcefully in response to catecholamines than the DV.In growth‐restricted human fetuses DV shunting is increased and the umbilical blood supply to the fetal liver is reduced. The long‐term reduction of the hepatic blood supply may be involved in fetal growth restriction. The occlusion of the DV leads to a significant increase in cell proliferation in fetal skeletal muscle, heart, kidneys and liver, and possibly to an increase in insulin‐like growth factor (IGF)‐I and ‐II mRNA expression in the fetal liver. These findings hint at the possible role of the perfusion of the fetal liver in the control of the growth process.The quantification of DV shunting by Doppler velocimetry may improve the early recognition of fetal compromise in prenatal medicine. In this Review we summarize the published data on the anatomical structure and histology of the DV, the mechanisms of regulation of DV shunting, its role in fetal survival and growth and the possible use of the measurement of DV shunting in clinical practice. Copyright © 2006 ISUOG. Published by John Wiley & Sons, Ltd.
- 13 January 2006
- Published by Wiley in Journal of Medical Primatology
- Vol. 35 (1) , 18-24
The ductus venosus and intrahepatic venous system in Callithrix jacchus jacchus and Macaca fascicularis fetuses
Background The ductus venosus (DV) and the intrahepatic branches of the portal vein are arranged as parallel vessels. Blood shunting through the DV ensures fetal survival during periods of stress. The availability of a suitable animal model with similar structure and function to the human fetus would greatly improve the understanding of DV function. The anatomical and histological structure of the DV has not been thoroughly investigated in non‐human primate species.Methods Morphological investigations were performed on eight marmoset (Callithrix jacchus jacchus) at 112.5 ± 5.5 days gestational age (mean ± SEM) and four near‐term (165 days) cynomolgus (Macaca fascicularis) fetuses.Results The DV drains into the collectus venosus. An asymmetrical muscular lip forms a contractile element of the isthmic portion of the DV. A spherical ‘dividing’ eminence was found on the dorsal wall of the venous collector just above the outlet of the DV in marmoset fetuses.Conclusions Our findings regarding the structure of the DV in cynomolgus and marmoset fetuses were generally in agreement with previous descriptions of the morpho‐histological structure of the DV in human fetuses.
- 13 January 2006
- Published by Wiley in Journal of Medical Primatology
- Vol. 35 (1) , 18-24
The ductus venosus and intrahepatic venous system in Callithrix jacchus jacchus and Macaca fascicularis fetuses
Background The ductus venosus (DV) and the intrahepatic branches of the portal vein are arranged as parallel vessels. Blood shunting through the DV ensures fetal survival during periods of stress. The availability of a suitable animal model with similar structure and function to the human fetus would greatly improve the understanding of DV function. The anatomical and histological structure of the DV has not been thoroughly investigated in non‐human primate species.Methods Morphological investigations were performed on eight marmoset (Callithrix jacchus jacchus) at 112.5 ± 5.5 days gestational age (mean ± SEM) and four near‐term (165 days) cynomolgus (Macaca fascicularis) fetuses.Results The DV drains into the collectus venosus. An asymmetrical muscular lip forms a contractile element of the isthmic portion of the DV. A spherical ‘dividing’ eminence was found on the dorsal wall of the venous collector just above the outlet of the DV in marmoset fetuses.Conclusions Our findings regarding the structure of the DV in cynomolgus and marmoset fetuses were generally in agreement with previous descriptions of the morpho‐histological structure of the DV in human fetuses.
- 1 April 2005
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 192 (4) , 1146-1152
Structural evidence for mechanisms to redistribute hepatic and ductus venosus blood flows in nonhuman primate fetuses
- 1 April 2005
- Published by Elsevier in American Journal of Obstetrics and Gynecology
- Vol. 192 (4) , 1146-1152
Structural evidence for mechanisms to redistribute hepatic and ductus venosus blood flows in nonhuman primate fetuses
- 24 December 2002
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 20 (6) , 580-585
Umbilical vein blood volume flow rate and umbilical artery pulsatility as ‘venous–arterial index’ in the prediction of neonatal compromise
Objective: To assess the diagnostic power of the umbilical venous–arterial index (VAI) for the prediction of poor fetal outcome.Subjects and methods: This was a retrospective, cross‐sectional clinical study in which normalized umbilical vein blood volume flow rate (nUV) (mL/min/kg estimated body weight), umbilical artery pulsatility index (UAPI), the newly developed VAI (nUV/UAPI), and the uterine artery resistance index (UTRI) were determined in 85 fetuses once (17–41 gestational weeks) during pregnancy using standard ultrasound Doppler equipment. A risk score based on umbilical blood pH, 1‐min Apgar score, birth weight, duration of gestation, type of respiratory support, and referral to the pediatric department was constructed, and fetuses were assigned to a control or a pathological group accordingly. Logistic regression and analysis of fitted receiver–operating characteristics curves were performed to evaluate the diagnostic power of nUV, UAPI, UTRI, and VAI.Results: The incidence of compromised neonates was 17.6%. The area under the receiver–operating characteristics curve was larger for VAI than for UTRI or for UAPI (P < 0.002). At a cut‐off value of 100 mL/min/kg, the sensitivity of VAI to predict poor neonatal outcome was 85% with a 15% false‐positive rate.Conclusion: Determination of the VAI has a greater diagnostic power to predict poor fetal outcome than the pulsatility index in the umbilical artery or the resistance index in the uterine artery. Copyright © 2002 International Society of Ultrasound in Obstetrics and Gynecology
- 24 December 2002
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 20 (6) , 580-585
Umbilical vein blood volume flow rate and umbilical artery pulsatility as ‘venous–arterial index’ in the prediction of neonatal compromise
Objective: To assess the diagnostic power of the umbilical venous–arterial index (VAI) for the prediction of poor fetal outcome.Subjects and methods: This was a retrospective, cross‐sectional clinical study in which normalized umbilical vein blood volume flow rate (nUV) (mL/min/kg estimated body weight), umbilical artery pulsatility index (UAPI), the newly developed VAI (nUV/UAPI), and the uterine artery resistance index (UTRI) were determined in 85 fetuses once (17–41 gestational weeks) during pregnancy using standard ultrasound Doppler equipment. A risk score based on umbilical blood pH, 1‐min Apgar score, birth weight, duration of gestation, type of respiratory support, and referral to the pediatric department was constructed, and fetuses were assigned to a control or a pathological group accordingly. Logistic regression and analysis of fitted receiver–operating characteristics curves were performed to evaluate the diagnostic power of nUV, UAPI, UTRI, and VAI.Results: The incidence of compromised neonates was 17.6%. The area under the receiver–operating characteristics curve was larger for VAI than for UTRI or for UAPI (P < 0.002). At a cut‐off value of 100 mL/min/kg, the sensitivity of VAI to predict poor neonatal outcome was 85% with a 15% false‐positive rate.Conclusion: Determination of the VAI has a greater diagnostic power to predict poor fetal outcome than the pulsatility index in the umbilical artery or the resistance index in the uterine artery. Copyright © 2002 International Society of Ultrasound in Obstetrics and Gynecology