Jian Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jian Wang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Chao Ma
Department of Radiology, Changhai Hospital of Shanghai, the Second Military Medical University, Shanghai, PR China
1 shared publicationHong Liu
Shanghai Changzheng Hospital
1 shared publicationJianping Lu
Department of Radiology, Changhai Hospital of Shanghai, the Second Military Medical University, Shanghai, PR China
1 shared publicationLuguang Chen
Department of Radiology, Changhai Hospital of Shanghai, the Second Military Medical University, Shanghai, PR China
1 shared publicationNingNing Zhang
University of Shanghai for Science and Technology
1 shared publicationTom Wj Scheenen
Department of Radiology, Radboud University Medical Centre, Nijmegen, Gelderland, The Netherlands
1 shared publication
Latest Publications
- Open Access
- 10 June 2025
- Published by Springer Nature in Research Square
Deep learning algorithm for predicting Gleason grade group based on prostate MRI image set
Accurate Gleason Grade Group (GGG) prediction in prostate cancer is crucial for prognosis and treatment decisions. Traditional biopsy, however, suffers from invasiveness, sampling error, and inconsistent pathological scoring. Thus, non-invasive, stable, and accurate imaging tools are urgently needed. In this study, we propose a Prostate Dual-branch Hybrid domain prediction Network (PDHD-Net) based on Multi-parametric MRI (mp-MRI) data to enable fine-grained Gleason Grade Group (GGG 1-5) stratification. we propose an innovative frequency-band-shunting feature-enhancement strategy. Specifically, Leveraging high-frequency information to enhance the subtle textural differences between lesion areas and surrounding tissues, while utilizing low-frequency information to accentuate overall structural and morphological patterns, through combining deep convolutional networks' sensitivity to local fine-grained features with self-attention mechanisms' capability to capture global semantic relationships achieves more accurate identification of lesion regions and Gleason Grade Group (GGG) prediction in MRI images. The FROC analysis of the multi-center dataset (including the public ProstateX-2 and private datasets) indicates that: PDHD-Net achieved sensitivities of 96.7% and 88.4% for high-risk (GGG=5) and clinically significant lesions, respectively, with an average of one false positive per patient. Compared with previous studies that uniformly grouped high-risk lesions into one group, this study achieved a fine distinction between GGG=4 and GGG=5. Furthermore, for the GS classification, evaluated by the receiver operating characteristics (ROC) analysis, PDHD-Net received the area under the curve of 0.82 for discriminating clinically significant PCa (GGG≥2) from GGG=1. Notably, the Dice of which distinguished Gleason's five classifications reached 0.80. The source code is available at https://github.com/NGYLK/PDHD-Net
- 10 June 2025
- Published by Springer Nature in Research Square
Open AccessDeep learning algorithm for predicting Gleason grade group based on prostate MRI image set
Accurate Gleason Grade Group (GGG) prediction in prostate cancer is crucial for prognosis and treatment decisions. Traditional biopsy, however, suffers from invasiveness, sampling error, and inconsistent pathological scoring. Thus, non-invasive, stable, and accurate imaging tools are urgently needed. In this study, we propose a Prostate Dual-branch Hybrid domain prediction Network (PDHD-Net) based on Multi-parametric MRI (mp-MRI) data to enable fine-grained Gleason Grade Group (GGG 1-5) stratification. we propose an innovative frequency-band-shunting feature-enhancement strategy. Specifically, Leveraging high-frequency information to enhance the subtle textural differences between lesion areas and surrounding tissues, while utilizing low-frequency information to accentuate overall structural and morphological patterns, through combining deep convolutional networks' sensitivity to local fine-grained features with self-attention mechanisms' capability to capture global semantic relationships achieves more accurate identification of lesion regions and Gleason Grade Group (GGG) prediction in MRI images. The FROC analysis of the multi-center dataset (including the public ProstateX-2 and private datasets) indicates that: PDHD-Net achieved sensitivities of 96.7% and 88.4% for high-risk (GGG=5) and clinically significant lesions, respectively, with an average of one false positive per patient. Compared with previous studies that uniformly grouped high-risk lesions into one group, this study achieved a fine distinction between GGG=4 and GGG=5. Furthermore, for the GS classification, evaluated by the receiver operating characteristics (ROC) analysis, PDHD-Net received the area under the curve of 0.82 for discriminating clinically significant PCa (GGG≥2) from GGG=1. Notably, the Dice of which distinguished Gleason's five classifications reached 0.80. The source code is available at https://github.com/NGYLK/PDHD-Net
- 27 October 2014
- Published by SAGE Publications in Acta Radiologica
- Vol. 56 (11) , 1342-1349
Three-dimensional proton magnetic resonance spectroscopic imaging with and without an endorectal coil: a prostate phantom study
Proton magnetic resonance spectroscopic imaging (MRSI) of the prostate has been used with only a combination of external surface coils. The quality of spectral fitting of the (choline + creatine)/citrate ([Cho + Cr]/Cit) ratio at different field strengths and different coils is important for quantitative/semi-quantitative diagnosis of prostate cancer. To evaluate the quality of spectral fitting of the (Cho + Cr)/Cit ratio of a prostate phantom using MRSI at different field strengths and various coils. Experiments were using 1.5-T and 3.0-T MR systems. Measurements were taken on a homemade prostate phantom with different coils: spinal array; abdominal array; and endorectal. The signal-to-noise ratio (SNR) of choline, creatine, and citrate peaks as well as the (Cho + Cr)/Cit ratio in each voxel were compared among groups using multi-way analysis of variance. Magnetic field strength, coils, and plane position had a significant effect on the SNR or (Cho + Cr)/Cit ratio, and there were interactions among groups (all P = 0.000). The 1.5-T (0.228 ± 0.044) exhibited a higher (Cho + Cr)/Cit ratio than the 3.0-T (0.125 ± 0.041) magnetic field strength (F = 3238, P = 0.000). The (Cho + Cr)/Cit ratio of both surface coils (0.183 ± 0.065) and all coils (0.181 ± 0.057) was significantly lower than that of the endorectal coil (0.195 ± 0.077) (both P < 0.05), but significant differences in the mean (Cho + Cr)/Cit ratio were not observed if surface coils and all coils were used (P > 0.05). No significant differences were found among the (Cho + Cr)/Cit ratios of all voxels in the middle planes by the post-hoc analyses (all P > 0.05). Three-dimensional proton MRSI of prostate metabolites in a phantom using surface coils is feasible and reliable, but (Cho + Cr)/Cit ratios acquired at different magnetic fields and coils were different. This difference should be taken into account when calculating this ratio in a field strength-independent way.
- 27 October 2014
- Published by SAGE Publications in Acta Radiologica
- Vol. 56 (11) , 1342-1349
Three-dimensional proton magnetic resonance spectroscopic imaging with and without an endorectal coil: a prostate phantom study
Proton magnetic resonance spectroscopic imaging (MRSI) of the prostate has been used with only a combination of external surface coils. The quality of spectral fitting of the (choline + creatine)/citrate ([Cho + Cr]/Cit) ratio at different field strengths and different coils is important for quantitative/semi-quantitative diagnosis of prostate cancer. To evaluate the quality of spectral fitting of the (Cho + Cr)/Cit ratio of a prostate phantom using MRSI at different field strengths and various coils. Experiments were using 1.5-T and 3.0-T MR systems. Measurements were taken on a homemade prostate phantom with different coils: spinal array; abdominal array; and endorectal. The signal-to-noise ratio (SNR) of choline, creatine, and citrate peaks as well as the (Cho + Cr)/Cit ratio in each voxel were compared among groups using multi-way analysis of variance. Magnetic field strength, coils, and plane position had a significant effect on the SNR or (Cho + Cr)/Cit ratio, and there were interactions among groups (all P = 0.000). The 1.5-T (0.228 ± 0.044) exhibited a higher (Cho + Cr)/Cit ratio than the 3.0-T (0.125 ± 0.041) magnetic field strength (F = 3238, P = 0.000). The (Cho + Cr)/Cit ratio of both surface coils (0.183 ± 0.065) and all coils (0.181 ± 0.057) was significantly lower than that of the endorectal coil (0.195 ± 0.077) (both P < 0.05), but significant differences in the mean (Cho + Cr)/Cit ratio were not observed if surface coils and all coils were used (P > 0.05). No significant differences were found among the (Cho + Cr)/Cit ratios of all voxels in the middle planes by the post-hoc analyses (all P > 0.05). Three-dimensional proton MRSI of prostate metabolites in a phantom using surface coils is feasible and reliable, but (Cho + Cr)/Cit ratios acquired at different magnetic fields and coils were different. This difference should be taken into account when calculating this ratio in a field strength-independent way.
- 20 May 2011
- Published by China Science Publishing & Media Ltd. in Academic Journal of Second Military Medical University
- Vol. 31 (5) , 580
Ectopic nodular goiter within carotid sheath: a case report
- 20 May 2011
- Published by China Science Publishing & Media Ltd. in Academic Journal of Second Military Medical University
- Vol. 31 (5) , 580
Ectopic nodular goiter within carotid sheath: a case report