JFJames W. Fletcher

James W. Fletcher

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


James W. Fletcher has a total of 35 co-authors. Here are the top co-authors by number of shared publications:

  • Carla J. Mathias

    Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN 46202, USA

    2 shared publications
  • Gary D. Hutchins

    Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN 46202, USA

    2 shared publications
  • Jacob A. Eitel

    Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN 46202, USA

    2 shared publications
  • Mark A. Green

    Department of Radiology and Imaging Sciences, Indiana University School of Medicine, Indianapolis, IN 46202, USA

    2 shared publications
  • R. Edward Coleman

    2 shared publications
  • Val J. Lowe

    2 shared publications

Latest Publications

  • Estimation of radiation dosimetry for 68Ga-HBED-CC (PSMA-11) in patients with suspected recurrence of prostate cancer

    by Mark A. Green, Jacob A. Eitel, James W. Fletcher, Carla J. Mathias, Mark A. Tann, Thomas Gardner, Michael O. Koch, Wendy Territo, Heather Polson, Gary D. Hutchins


  • Whole-Body PET/CT Evaluation of Tumor Perfusion Using Generator-Based 62Cu-Ethylglyoxal Bis(Thiosemicarbazonato)Copper(II): Validation by Direct Comparison to 15O-Water in Metastatic Renal Cell Carcinoma

    by James W. Fletcher, Theodore F. Logan, Jacob A. Eitel, Carla J. Mathias, Yen Ng, Jeffrey L. Lacy, Gary D. Hutchins, Mark A. Green

    This study was undertaken to demonstrate the feasibility of whole-body 62Cu-ethylglyoxal bis(thiosemicarbazonato)copper(II) (62Cu-ETS) PET/CT tumor perfusion imaging in patients with metastatic renal carcinoma and to validate 62Cu-ETS as a quantitative marker of tumor perfusion by direct comparison with 15O-water perfusion imaging. Methods: PET/CT imaging of 10 subjects with stage IV renal cell cancer was performed after intravenous administration of 15O-water (10-min dynamic list-mode study) with the heart and at least 1 tumor in the PET field of view, followed 10 min later by intravenous 62Cu-ETS (6-min list-mode study). Whole-body 62Cu imaging was then performed from 6 to 20 min at 2–3 min/bed position. Blood flow (K1) was quantified with both agents for normal and malignant tissues in the 21.7-cm dynamic field of view. The required arterial input functions were derived from the left atrium and, in the case of 62Cu-ETS, corrected for partial decomposition of the agent by blood with data from an in vitro analysis using a sample of each patient’s blood. This imaging protocol was repeated at an interval of 3–4 wk after initiation of a standard clinical treatment course of the antiangiogenic agent sunitinib. Results: All subjects received the scheduled 62Cu-ETS doses for the dynamic and subsequent whole-body PET/CT scans, but technical issues resulted in no baseline 15O-water data for 2 subjects. Direct comparisons of the perfusion estimates for normal tissues and tumor metastases were made in 18 paired baseline and treatment studies (10 subjects; 8 baseline studies, 10 repeated studies during treatment). There was an excellent correlation between the blood flow estimates made with 62Cu-ETS and 15O-water for normal tissues (muscle, thyroid, myocardium) and malignant lesions (pulmonary nodules, bone lesions); the regression line was y = 0.85x + 0.15, R2 = 0.83, for the 88 regions analyzed. Conclusion:62Cu-ETS provided high-quality whole-body PET/CT images, and 62Cu-ETS measures of blood flow were highly and linearly correlated with 15O-water–derived K1 values (mL−1⋅min−1⋅g). This tracer is suitable for use as a PET tracer of tumor perfusion in patients with metastatic renal cell carcinoma.


  • Top Cited Papers
    Open Access

    Recommendations on the Use of 18F-FDG PET in Oncology

    by James W. Fletcher, Benjamin Djulbegovic, Heloisa P. Soares, Barry A. Siegel, Val J. Lowe, Gary H. Lyman, R. Edward Coleman, Richard Wahl, John Christopher Paschold, Norbert Avril, et al.

    The rationale was to develop recommendations on the use of 18F-FDG PET in breast, colorectal, esophageal, head and neck, lung, pancreatic, and thyroid cancer; lymphoma, melanoma, and sarcoma; and unknown primary tumor. Outcomes of interest included the use of 18F-FDG PET for diagnosing, staging, and detecting the recurrence or progression of cancer. Methods: A search was performed to identify all published randomized controlled trials and systematic reviews in the literature. An additional search was performed to identify relevant unpublished systematic reviews. These publications comprised both retrospective and prospective studies of varied methodologic quality. The anticipated consequences of false-positive and false-negative tests when evaluating clinical usefulness, and the impact of 18F-FDG PET on the management of cancer patients, were also reviewed. Results and Conclusion: 18F-FDG PET should be used as an imaging tool additional to conventional radiologic methods such as CT or MRI; any positive finding that could lead to a clinically significant change in patient management should be confirmed by subsequent histopathologic examination because of the risk of false-positive results. 18F-FDG PET should be used in the appropriate clinical setting for the diagnosis of head and neck, lung, or pancreatic cancer and for unknown primary tumor. PET is also indicated for staging of breast, colon, esophageal, head and neck, and lung cancer and of lymphoma and melanoma. In addition, 18F-FDG PET should be used to detect recurrence of breast, colorectal, head and neck, or thyroid cancer and of lymphoma.


  • Open Access

    A Comparison of the Diagnostic Accuracy of18F-FDG PET and CT in the Characterization of Solitary Pulmonary Nodules

    by James W. Fletcher, Steven M. Kymes, Michael Gould, Naomi Alazraki, R. Edward Coleman, Val J. Lowe, Charles Marn, George Segall, Lyn A. Thet, Kelvin Lee, et al.

    CT and PET are widely used to characterize solitary pulmonary nodules (SPNs). However, most CT accuracy studies have been performed with outdated technology and methods, and previous PET studies have been limited by small sample sizes and incomplete masking. Our objective was to compare CT and PET accuracy in veterans with SPN. Methods: Between January 1999 and June 2001, we recruited 532 participants with SPNs newly diagnosed on radiography and untreated. The SPNs were 7–30 mm. All patients underwent 18F-FDG PET and CT. A masked panel of 3 PET and 3 CT experts rated the studies on a 5-point scale. SPN tissue diagnosis or 2-y follow-up established the final diagnosis. Results: A definitive diagnosis was established for 344 participants. The prevalence of malignancy was 53%. The average size was 16 mm. Likelihood ratios (LRs) for PET and CT results for combined ratings of either definitely benign (33% and 9% of patients, respectively) or probably benign (27% and 12%) were 0.10 and 0.11, respectively. LRs for PET and CT results for combined ratings of indeterminate (1% and 25%), probably malignant (21% and 39%), or definitely malignant (35% and 15%) were 5.18 and 1.61, respectively. Area under the receiver operating characteristic curve was 0.93 (95% confidence interval, 0.90–0.95) for PET and 0.82 (95% confidence interval, 0.77–0.86) for CT (P < 0.0001 for the difference). PET inter- and intraobserver reliability was superior to CT. Conclusion: Definitely and probably benign results on PET and CT strongly predict benign SPN. However, such results were 3 times more common with PET. Definitely malignant results on PET were much more predictive of malignancy than were these results on CT. A malignant final diagnosis was approximately 10 times more likely than a benign final diagnosis in participants with PET results rated definitely malignant.