Jeng Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jeng Wei has a total of 119 co-authors. Here are the top co-authors by number of shared publications:
Chung-Yi Chang
Heart Center, Cheng-Hsin General Hospital, Taipei, Taiwan
9 shared publicationsYung-Tsai Lee
Heart Center, Cheng Hsin General Hospital , No. 45, Cheng Hsin St, Beitou , Taipei, 112 Taiwan, Republic of China
8 shared publicationsWei-Hsian Yin
Heart Center, Cheng Hsin General Hospital, Taipei
7 shared publicationsHeng-Hsin Tung
5 shared publicationsC.-Y. Chang
Division of Cardiovascular Surgery, Heart Center, Cheng Hsin General Hospital, Taipei, Taiwan, Republic of China
4 shared publicationsKuo-Chen Lee
Heart Center, Cheng Hsin General Hospital, Taipei
4 shared publications
Latest Publications
- Open Access
Stretchable, Adhesive, and Biocompatible Hydrogel Based on Iron–Dopamine Complexes
Hydrogels’ exceptional mechanical strength and skin-adhesion characteristics offer significant advantages for various applications, particularly in the fields of tissue adhesion and wearable sensors. Herein, we incorporated a combination of metal-coordination and hydrogen-bonding forces in the design of stretchable and adhesive hydrogels. We synthesized four hydrogels, namely PAID-0, PAID-1, PAID-2, and PAID-3, consisting of acrylamide (AAM), N,N′-methylene-bis-acrylamide (MBA), and methacrylic-modified dopamine (DA). The impact of different ratios of iron (III) ions to DA on each hydrogel’s performance was investigated. Our results demonstrate that the incorporation of iron–dopamine complexes significantly enhances the mechanical strength of the hydrogel. Interestingly, as the DA content increased, we observed a continuous and substantial improvement in both the stretchability and skin adhesiveness of the hydrogel. Among the hydrogels tested, PAID-3, which exhibited optimal mechanical properties, was selected for adhesion testing on various materials. Impressively, PAID-3 demonstrated excellent adhesion to diverse materials and, combined with the low cytotoxicity of PAID hydrogel, holds great promise as an innovative option for biomedical engineering applications.
Open AccessStretchable, Adhesive, and Biocompatible Hydrogel Based on Iron–Dopamine Complexes
Hydrogels’ exceptional mechanical strength and skin-adhesion characteristics offer significant advantages for various applications, particularly in the fields of tissue adhesion and wearable sensors. Herein, we incorporated a combination of metal-coordination and hydrogen-bonding forces in the design of stretchable and adhesive hydrogels. We synthesized four hydrogels, namely PAID-0, PAID-1, PAID-2, and PAID-3, consisting of acrylamide (AAM), N,N′-methylene-bis-acrylamide (MBA), and methacrylic-modified dopamine (DA). The impact of different ratios of iron (III) ions to DA on each hydrogel’s performance was investigated. Our results demonstrate that the incorporation of iron–dopamine complexes significantly enhances the mechanical strength of the hydrogel. Interestingly, as the DA content increased, we observed a continuous and substantial improvement in both the stretchability and skin adhesiveness of the hydrogel. Among the hydrogels tested, PAID-3, which exhibited optimal mechanical properties, was selected for adhesion testing on various materials. Impressively, PAID-3 demonstrated excellent adhesion to diverse materials and, combined with the low cytotoxicity of PAID hydrogel, holds great promise as an innovative option for biomedical engineering applications.
- Open Access
- 2 November 2023
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 7 (11) , ytad516
A case report of transcatheter closure of post-Bentall ascending aortic pseudoaneurysm due to coronary button dehiscence
Background: Ascending aortic pseudoaneurysm due to coronary button dehiscence is a rare, yet life-threatening complication of reconstructive cardiac surgery. Because of its rare entity, large data are lacking, and therefore, treatment guidelines are missing. Case summary: We describe a case of a 53-year-old male with a past medical history of ascending aortic aneurysm and severe aortic regurgitation who underwent Bentall procedure with 26 mm conduit and mechanical aortic valve 1 year before. Follow-up chest computed tomography (CT) revealed coronary button dehiscence with a giant aortic root pseudoaneurysm and mural thrombus inside. Given the risk of rupture, the heart team decided to go for a percutaneous approach. Based on a pre-interventional 3D reconstructed CT scan and guided by transoesophageal echocardiography and intravascular ultrasound, the pseudoaneurysm was successfully occluded with a 6 × 4 mm Amplatzer Duct Occluder II and simultaneous left main coronary artery (LMCA) stenting with a 4.0 × 15 mm drug-eluting stent. Post-procedural chest CT and echocardiography revealed minimal contrast leakage posterior to the aortic root and para LMCA region, confirmed thrombosis formation post occluder and stent deployment, and patent flow of LMCA. Discussion: We describe the successful 3D reconstructed CT scan and peri-procedural transoesophageal echocardiography–guided percutaneous treatment of a giant aortic root pseudoaneurysm with an occluder and a drug-eluting stent with excellent results.
- 2 November 2023
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 7 (11) , ytad516
Open AccessA case report of transcatheter closure of post-Bentall ascending aortic pseudoaneurysm due to coronary button dehiscence
Background: Ascending aortic pseudoaneurysm due to coronary button dehiscence is a rare, yet life-threatening complication of reconstructive cardiac surgery. Because of its rare entity, large data are lacking, and therefore, treatment guidelines are missing. Case summary: We describe a case of a 53-year-old male with a past medical history of ascending aortic aneurysm and severe aortic regurgitation who underwent Bentall procedure with 26 mm conduit and mechanical aortic valve 1 year before. Follow-up chest computed tomography (CT) revealed coronary button dehiscence with a giant aortic root pseudoaneurysm and mural thrombus inside. Given the risk of rupture, the heart team decided to go for a percutaneous approach. Based on a pre-interventional 3D reconstructed CT scan and guided by transoesophageal echocardiography and intravascular ultrasound, the pseudoaneurysm was successfully occluded with a 6 × 4 mm Amplatzer Duct Occluder II and simultaneous left main coronary artery (LMCA) stenting with a 4.0 × 15 mm drug-eluting stent. Post-procedural chest CT and echocardiography revealed minimal contrast leakage posterior to the aortic root and para LMCA region, confirmed thrombosis formation post occluder and stent deployment, and patent flow of LMCA. Discussion: We describe the successful 3D reconstructed CT scan and peri-procedural transoesophageal echocardiography–guided percutaneous treatment of a giant aortic root pseudoaneurysm with an occluder and a drug-eluting stent with excellent results.
- Open Access
- 29 November 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (23) , 7084
Utilization of Two- and Three-Dimensional Transesophageal Echocardiography in Successfully Guiding Transcatheter Mitral Valve in Bioprosthetic Mitral Valve/Mitral Ring Implantation without Complications in Patients with Thrombus in Left Atrium/Left Atrial Appendage
Background. The aim of this study is to describe, for the first time to our knowledge, the utilization of both two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE) in successfully performing transcatheter mitral valve (MV) in bioprosthetic MV/MV annulopasty ring implantation using the apical approach in 12 patients (pts) with co-existing left atrial appendage (LAA) and/or LA (left atrium) body thrombus, which is considered a contraindication for this procedure. Methods and Results. All pts were severely symptomatic with severe bioprosthetic MV stenosis/regurgitation except one with a previous MV annuloplasty ring and severe native MV stenosis. Thrombus in LAA and/or LA body was noted in all by 2D and 3DTEE. All were at high/prohibitive risk for redo operation and all refused surgery. Utilizing both 2D and 3DTEE, especially 3DTEE, guidewires and the prosthesis deployment system could be manipulated under direct vision into the LA avoiding any contact with the thrombus. The procedure was successful in all with amelioration of symptoms and no embolic or other complications over a mean follow-up of 21 months. Conclusion. Our study demonstrates the feasibility of successfully performing this procedure in pts with thrombus in LAA and/or LA body without any complications.
- 29 November 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (23) , 7084
Open AccessUtilization of Two- and Three-Dimensional Transesophageal Echocardiography in Successfully Guiding Transcatheter Mitral Valve in Bioprosthetic Mitral Valve/Mitral Ring Implantation without Complications in Patients with Thrombus in Left Atrium/Left Atrial Appendage
Background. The aim of this study is to describe, for the first time to our knowledge, the utilization of both two-dimensional (2D) and three-dimensional (3D) transesophageal echocardiography (TEE) in successfully performing transcatheter mitral valve (MV) in bioprosthetic MV/MV annulopasty ring implantation using the apical approach in 12 patients (pts) with co-existing left atrial appendage (LAA) and/or LA (left atrium) body thrombus, which is considered a contraindication for this procedure. Methods and Results. All pts were severely symptomatic with severe bioprosthetic MV stenosis/regurgitation except one with a previous MV annuloplasty ring and severe native MV stenosis. Thrombus in LAA and/or LA body was noted in all by 2D and 3DTEE. All were at high/prohibitive risk for redo operation and all refused surgery. Utilizing both 2D and 3DTEE, especially 3DTEE, guidewires and the prosthesis deployment system could be manipulated under direct vision into the LA avoiding any contact with the thrombus. The procedure was successful in all with amelioration of symptoms and no embolic or other complications over a mean follow-up of 21 months. Conclusion. Our study demonstrates the feasibility of successfully performing this procedure in pts with thrombus in LAA and/or LA body without any complications.
- Open Access
- 18 November 2022
- Published by MDPI AG in Healthcare
- Vol. 10 (11) , 2311
Factors Influencing Sleep Quality in Open-Heart Patients in the Postoperative Intensive Care Unit
Open-heart patients often experience sleep problems postoperatively. This cross-sectional study is aimed to investigate open-heart patients’ sleep quality and its influencing factors during intensive care. A consecutive sample of 117 eligible open-heart patients was recruited from an intensive care unit (ICU) of a general hospital. Data were collected using questionnaires. The respondents were 22–88 years, with a median age of 60.25 (13.51). Seventy-nine (67.5%) respondents were male. Most respondents reported a low-to-moderate postoperative pain level (average pain score = 2.02; range: 0–10). The average anxiety score was 4.68 (standard deviation [SD] = 4.2), and the average depression score was 6.91 (SD = 4.52; range: 0–21). The average sleep efficiency index was 70.4% (SD = 10.74%). Most (95.7%) respondents had a sleep efficiency index below 85%, indicating that most patients did not sleep well in the ICU. Linear regression analysis showed that the key predictors of the sleep quality of open-heart patients in the ICU were wound pain (β = −1.9) and noise disturbance (β = −1.86). These results provide information on sleep quality and the factors affecting postoperative patients in the ICU. These findings can be used as a reference for developing relevant interventions.
- 18 November 2022
- Published by MDPI AG in Healthcare
- Vol. 10 (11) , 2311
Open AccessFactors Influencing Sleep Quality in Open-Heart Patients in the Postoperative Intensive Care Unit
Open-heart patients often experience sleep problems postoperatively. This cross-sectional study is aimed to investigate open-heart patients’ sleep quality and its influencing factors during intensive care. A consecutive sample of 117 eligible open-heart patients was recruited from an intensive care unit (ICU) of a general hospital. Data were collected using questionnaires. The respondents were 22–88 years, with a median age of 60.25 (13.51). Seventy-nine (67.5%) respondents were male. Most respondents reported a low-to-moderate postoperative pain level (average pain score = 2.02; range: 0–10). The average anxiety score was 4.68 (standard deviation [SD] = 4.2), and the average depression score was 6.91 (SD = 4.52; range: 0–21). The average sleep efficiency index was 70.4% (SD = 10.74%). Most (95.7%) respondents had a sleep efficiency index below 85%, indicating that most patients did not sleep well in the ICU. Linear regression analysis showed that the key predictors of the sleep quality of open-heart patients in the ICU were wound pain (β = −1.9) and noise disturbance (β = −1.86). These results provide information on sleep quality and the factors affecting postoperative patients in the ICU. These findings can be used as a reference for developing relevant interventions.
- Open Access
- 12 August 2022
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 24 (8) , e40288
Factors Associated With the Utilization of Outpatient Virtual Clinics: Retrospective Observational Study Using Multilevel Analysis
Background: Although the COVID-19 pandemic has accelerated the adoption of telemedicine and virtual consultations worldwide, complex factors that may affect the use of virtual clinics are still unclear. Objective: This study aims to identify factors associated with the utilization of virtual clinics in the experience of virtual clinic service implementation in Taiwan. Methods: We retrospectively analyzed a total of 187,742 outpatient visits (176,815, 94.2%, in-person visits and 10,927, 5.8%, virtual visits) completed at a large general hospital in Taipei City from May 19 to July 31, 2021, after rapid implementation of virtual outpatient clinic visits due to the COVID-19 pandemic. Data of patients’ demographic characteristics, disease type, physicians’ features, and specialties/departments were collected, and physicians’ opinions regarding virtual clinics were surveyed and evaluated using a 5-point Likert scale. Multilevel analysis was conducted to determine the factors associated with the utilization of virtual clinics. Results: Patient-/visit-, physician-, and department-level factors accounted for 67.5%, 11.1%, and 21.4% of the total variance in the utilization of virtual clinics, respectively. Female sex (odds ratio [OR] 1.27, 95% CI 1.22-1.33, P<.001); residing at a greater distance away from the hospital (OR 2.36, 95% CI 2.15-2.58 if distance>50 km, P<.001; OR 3.95, 95% CI 3.11-5.02 if extensive travel required, P<.001); reimbursement by the National Health Insurance (NHI; OR 7.29, 95% CI 5.71-9.30, P<.001); seeking care for a major chronic disease (OR 1.33, 95% CI 1.24-1.42, P<.001); the physician’s positive attitude toward virtual clinics (OR 1.50, 95% CI 1.16-1.93, P=.002); and visits within certain departments, including the heart center, psychiatry, and internal medicine (OR 2.55, 95% CI 1.46-4.46, P=.004), were positively associated with the utilization of virtual clinics. The patient’s age, the physician’s age, and the physician’s sex were not associated with the utilization of virtual clinics in our study. Conclusions: Our results show that in addition to previously demonstrated patient-level factors that may influence telemedicine use, including the patient’s sex and distance from the hospital, factors at the visit level (insurance type, disease type), physician level (physician’s attitude toward virtual clinics), and department level also contribute to the utilization of virtual clinics. Although there was a more than 300-fold increase in the number of virtual visits during the pandemic compared with the prepandemic period, the majority (176,815/187,742, 94.2%) of the outpatient visits were still in-person visits during the study period. Therefore, it is of great importance to understand the factors impacting the utilization of virtual clinics to accelerate the implementation of telemedicine. The findings of our study may help direct policymaking for expanding the use of virtual clinics, especially in countries struggling with the development and promotion of telemedicine virtual clinic services.
- 12 August 2022
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 24 (8) , e40288
Open AccessFactors Associated With the Utilization of Outpatient Virtual Clinics: Retrospective Observational Study Using Multilevel Analysis
Background: Although the COVID-19 pandemic has accelerated the adoption of telemedicine and virtual consultations worldwide, complex factors that may affect the use of virtual clinics are still unclear. Objective: This study aims to identify factors associated with the utilization of virtual clinics in the experience of virtual clinic service implementation in Taiwan. Methods: We retrospectively analyzed a total of 187,742 outpatient visits (176,815, 94.2%, in-person visits and 10,927, 5.8%, virtual visits) completed at a large general hospital in Taipei City from May 19 to July 31, 2021, after rapid implementation of virtual outpatient clinic visits due to the COVID-19 pandemic. Data of patients’ demographic characteristics, disease type, physicians’ features, and specialties/departments were collected, and physicians’ opinions regarding virtual clinics were surveyed and evaluated using a 5-point Likert scale. Multilevel analysis was conducted to determine the factors associated with the utilization of virtual clinics. Results: Patient-/visit-, physician-, and department-level factors accounted for 67.5%, 11.1%, and 21.4% of the total variance in the utilization of virtual clinics, respectively. Female sex (odds ratio [OR] 1.27, 95% CI 1.22-1.33, P<.001); residing at a greater distance away from the hospital (OR 2.36, 95% CI 2.15-2.58 if distance>50 km, P<.001; OR 3.95, 95% CI 3.11-5.02 if extensive travel required, P<.001); reimbursement by the National Health Insurance (NHI; OR 7.29, 95% CI 5.71-9.30, P<.001); seeking care for a major chronic disease (OR 1.33, 95% CI 1.24-1.42, P<.001); the physician’s positive attitude toward virtual clinics (OR 1.50, 95% CI 1.16-1.93, P=.002); and visits within certain departments, including the heart center, psychiatry, and internal medicine (OR 2.55, 95% CI 1.46-4.46, P=.004), were positively associated with the utilization of virtual clinics. The patient’s age, the physician’s age, and the physician’s sex were not associated with the utilization of virtual clinics in our study. Conclusions: Our results show that in addition to previously demonstrated patient-level factors that may influence telemedicine use, including the patient’s sex and distance from the hospital, factors at the visit level (insurance type, disease type), physician level (physician’s attitude toward virtual clinics), and department level also contribute to the utilization of virtual clinics. Although there was a more than 300-fold increase in the number of virtual visits during the pandemic compared with the prepandemic period, the majority (176,815/187,742, 94.2%) of the outpatient visits were still in-person visits during the study period. Therefore, it is of great importance to understand the factors impacting the utilization of virtual clinics to accelerate the implementation of telemedicine. The findings of our study may help direct policymaking for expanding the use of virtual clinics, especially in countries struggling with the development and promotion of telemedicine virtual clinic services.
- Open Access
- 1 January 2022
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 10 (1) , 24
Outcomes of transcatheter aortic valve replacement for pure native aortic regurgitation with the use of newer- vs. early-generation devices
Background: Accumulated experience and advances in device technology have led to the increasing off-label use of transcatheter aortic valve replacement (TAVR) for pure native aortic valve regurgitation (PNAR). This study aimed to evaluate the procedural and long-term outcomes of using newer-generation transcatheter heart valves (THVs) versus early-generation self-expanding CoreValve (Medtronic, Minneapolis, USA) to treat PNAR. Methods: TAVRs were performed with the use of early- (N=15) and newer-generation (N=10) THVs in a total of 25 consecutive PNAR patients at an intermediate-to-high risk for surgical aortic valve replacement [mean Society of Thoracic Surgeons (STS) score of 6.8±4.5]. Procedural and clinical outcomes were reported according to the Valve Academic Research Consortium 2 criteria. The primary end-point of the study was all-cause mortality, myocardial infarction (MI), disabling stroke, and readmission due to heart failure. Results: The device success rate of the newer-generation THVs was significantly higher than that of the early-generation CoreValve (100% vs. 33%, Pvs. 53%, PConclusions: Evidently, the treatment of PNAR with TAVR using the newer-generation THVs yielded better procedural outcomes and is a valuable therapeutic option in selective patients. Keywords: Transcatheter aortic valve replacement (TAVR); pure native aortic regurgitation (AR); transcatheter heart valves (THVs); procedural and clinical outcomes
- 1 January 2022
- Published by AME Publishing Company in Annals of Translational Medicine
- Vol. 10 (1) , 24
Open AccessOutcomes of transcatheter aortic valve replacement for pure native aortic regurgitation with the use of newer- vs. early-generation devices
Background: Accumulated experience and advances in device technology have led to the increasing off-label use of transcatheter aortic valve replacement (TAVR) for pure native aortic valve regurgitation (PNAR). This study aimed to evaluate the procedural and long-term outcomes of using newer-generation transcatheter heart valves (THVs) versus early-generation self-expanding CoreValve (Medtronic, Minneapolis, USA) to treat PNAR. Methods: TAVRs were performed with the use of early- (N=15) and newer-generation (N=10) THVs in a total of 25 consecutive PNAR patients at an intermediate-to-high risk for surgical aortic valve replacement [mean Society of Thoracic Surgeons (STS) score of 6.8±4.5]. Procedural and clinical outcomes were reported according to the Valve Academic Research Consortium 2 criteria. The primary end-point of the study was all-cause mortality, myocardial infarction (MI), disabling stroke, and readmission due to heart failure. Results: The device success rate of the newer-generation THVs was significantly higher than that of the early-generation CoreValve (100% vs. 33%, Pvs. 53%, PConclusions: Evidently, the treatment of PNAR with TAVR using the newer-generation THVs yielded better procedural outcomes and is a valuable therapeutic option in selective patients. Keywords: Transcatheter aortic valve replacement (TAVR); pure native aortic regurgitation (AR); transcatheter heart valves (THVs); procedural and clinical outcomes
- Open Access
- 20 May 2021
- Published by Wolters Kluwer Health in Journal of Cardiovascular Nursing
- Vol. 36 (6) , 565-572
Malnutrition, Family Support, and Possible Sarcopenia in Patients Undergoing Transcatheter Aortic Valve Implantation
Background: Possible sarcopenia, aortic valve stenosis, and malnutrition are important issues that afflict older adults. Objective: The aims of this study were to compare the differences in nutritional status and family support in older adults with possible sarcopenia and those without sarcopenia after undergoing transcatheter aortic valve implantation (TAVI) and to identify the predictors of malnutrition and demonstrate changes in heart function over time after undergoing TAVI. Methods: A case-control design was conducted. Possible sarcopenia was identified by measuring calf circumference, grip strength, and gait speed. The Mini Nutritional Assessment-Short Form and numerical family support rating scale were used to collect data. Left ventricular ejection fraction and New York Heart Association (NYHA) functional class were assessed at 5 time points to evaluate heart function. Results: Eighty-one participants were categorized into those without sarcopenia (34) and those with possible sarcopenia (47). Logistic linear regression showed albumin and possible sarcopenia to be predictors of malnutrition (odds ratio, 5.5; 95% confidence interval, 1.02–30.19). Family support was associated with nutrition status (P = .019). For patient heart function, the results of NYHA functional class and left ventricular ejection fraction improved over time after TAVI. The improvement in NYHA functional class at T2 was significantly different between the 2 groups compared with that at T0. Conclusions: The nutrition level was higher among participants without sarcopenia than those with possible sarcopenia. Approximately 90% of the participants indicated that they had high family support. Demographic factors and albumin levels could be used to evaluate risk of malnutrition. Patients without possible sarcopenia showed greater improvement in NYHA class.
- 20 May 2021
- Published by Wolters Kluwer Health in Journal of Cardiovascular Nursing
- Vol. 36 (6) , 565-572
Open AccessMalnutrition, Family Support, and Possible Sarcopenia in Patients Undergoing Transcatheter Aortic Valve Implantation
Background: Possible sarcopenia, aortic valve stenosis, and malnutrition are important issues that afflict older adults. Objective: The aims of this study were to compare the differences in nutritional status and family support in older adults with possible sarcopenia and those without sarcopenia after undergoing transcatheter aortic valve implantation (TAVI) and to identify the predictors of malnutrition and demonstrate changes in heart function over time after undergoing TAVI. Methods: A case-control design was conducted. Possible sarcopenia was identified by measuring calf circumference, grip strength, and gait speed. The Mini Nutritional Assessment-Short Form and numerical family support rating scale were used to collect data. Left ventricular ejection fraction and New York Heart Association (NYHA) functional class were assessed at 5 time points to evaluate heart function. Results: Eighty-one participants were categorized into those without sarcopenia (34) and those with possible sarcopenia (47). Logistic linear regression showed albumin and possible sarcopenia to be predictors of malnutrition (odds ratio, 5.5; 95% confidence interval, 1.02–30.19). Family support was associated with nutrition status (P = .019). For patient heart function, the results of NYHA functional class and left ventricular ejection fraction improved over time after TAVI. The improvement in NYHA functional class at T2 was significantly different between the 2 groups compared with that at T0. Conclusions: The nutrition level was higher among participants without sarcopenia than those with possible sarcopenia. Approximately 90% of the participants indicated that they had high family support. Demographic factors and albumin levels could be used to evaluate risk of malnutrition. Patients without possible sarcopenia showed greater improvement in NYHA class.
- 1 September 2020
- Vol. 36 (5) , 409-415
Delayed Coronary Obstruction after Transcatheter Aortic Valve Replacement - An Uncommon But Serious Complication
As transcatheter aortic valve replacement (TAVR) becomes the mainstream treatment for valvular aortic stenosis, it is vitally important to recognize its associated procedural complications. Among the clinically relevant but uncommonly seen complications, the development of delayed coronary obstruction (DCO) occurring during the early post-procedural phase or even later following the index TAVR procedure, has been reported. These reports have raised concerns as TAVR comes more common in lower-risk patients. In this review article, we explored the implications of DCO for pre-procedural computed tomography evaluation, valve selection and sizing, intra-procedural manipulation, and approaches to post-procedural management.
- 1 September 2020
- Vol. 36 (5) , 409-415
Delayed Coronary Obstruction after Transcatheter Aortic Valve Replacement - An Uncommon But Serious Complication
As transcatheter aortic valve replacement (TAVR) becomes the mainstream treatment for valvular aortic stenosis, it is vitally important to recognize its associated procedural complications. Among the clinically relevant but uncommonly seen complications, the development of delayed coronary obstruction (DCO) occurring during the early post-procedural phase or even later following the index TAVR procedure, has been reported. These reports have raised concerns as TAVR comes more common in lower-risk patients. In this review article, we explored the implications of DCO for pre-procedural computed tomography evaluation, valve selection and sizing, intra-procedural manipulation, and approaches to post-procedural management.
- Open Access
- 1 January 2019
- Published by Wolters Kluwer Health in Medicine
- Vol. 98 (3) , e14118
Nonthrombotic pulmonary embolism caused by intravenous leiomyomatosis
Pulmonary embolism is a potentially devastating medical condition. Although deep-vein thrombosis is the most common etiology, a nonthrombotic pulmonary embolism is not uncommon. A 45-year-old woman was admitted to our hospital for progressive effort dyspnea for 3 weeks. Echocardiography revealed a mobile mass extending from the right atrium to the bilateral proximal pulmonary artery. As the mass was no response to thrombotic therapy, intravenous leiomyomatosis was suspected. Computed tomography (CT) revealed a hypo-attenuated tumor extending from the ovarian vein to the pulmonary artery. A 1-stage operation for the surgical removal of the tumor, right salpingo-oophorectomy and subtotal hysterectomy were performed. Surgical specimen was identified as uterine leiomyomatosis without malignant transformation. The patient was followed- up for 2 years and subsequent CT did not reveal any notable lesions. Nonthrombotic pulmonary embolism is a potentially life-threatening complication. This case indicated intravenous leiomyomatosis should be considered in the differential diagnosis for certain cases. Complete surgical excision was the only curative treatment.
- 1 January 2019
- Published by Wolters Kluwer Health in Medicine
- Vol. 98 (3) , e14118
Open AccessNonthrombotic pulmonary embolism caused by intravenous leiomyomatosis
Pulmonary embolism is a potentially devastating medical condition. Although deep-vein thrombosis is the most common etiology, a nonthrombotic pulmonary embolism is not uncommon. A 45-year-old woman was admitted to our hospital for progressive effort dyspnea for 3 weeks. Echocardiography revealed a mobile mass extending from the right atrium to the bilateral proximal pulmonary artery. As the mass was no response to thrombotic therapy, intravenous leiomyomatosis was suspected. Computed tomography (CT) revealed a hypo-attenuated tumor extending from the ovarian vein to the pulmonary artery. A 1-stage operation for the surgical removal of the tumor, right salpingo-oophorectomy and subtotal hysterectomy were performed. Surgical specimen was identified as uterine leiomyomatosis without malignant transformation. The patient was followed- up for 2 years and subsequent CT did not reveal any notable lesions. Nonthrombotic pulmonary embolism is a potentially life-threatening complication. This case indicated intravenous leiomyomatosis should be considered in the differential diagnosis for certain cases. Complete surgical excision was the only curative treatment.