Cagatay Yelkarasi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Cagatay Yelkarasi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Mustafa Urgen
Metallurgical and Materials Engineering Department, Istanbul Technical University, 34469 Maslak, Istanbul, Turkey
2 shared publications - Ali Erdemir
Department of Mechanical Engineering, Texas A&M University, College Station, USA
1 shared publication Ammar Aksoy
Department of Metallurgical and Materials Engineering, Istanbul Technical University, Istanbul, Türkiye
1 shared publication- Beste Payam
Department of Metallurgical and Materials Engineering, Istanbul Technical University, Istanbul, Türkiye
1 shared publication - Bilgehan Sesen
Max Planck Institute for Sustainable Materials, Düsseldorf, Germany
1 shared publication - Cem Örnek
Department of Metallurgical and Materials Engineering, Istanbul Technical University, Istanbul, Turkey
1 shared publication
Latest Publications
- Open Access
- 5 May 2026
- Published by Springer Nature in Communications Materials
- Vol. 7 (1)
Real-time mapping of hydrogen diffusion in steel
- 5 May 2026
- Published by Springer Nature in Communications Materials
- Vol. 7 (1)
Open AccessReal-time mapping of hydrogen diffusion in steel
- Open Access
- 21 April 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (9) , 4595
Biocompatibility and Mechanical Stability of Nanopatterned Titanium Films on Stainless Steel Vascular Stents
Nanoporous ceramic coatings such as titania are promoted to produce drug-free cardiovascular stents with a low risk of in-stent restenosis (ISR) because of their selectivity towards vascular cell proliferation. The brittle coatings applied on stents are prone to cracking because they are subjected to plastic deformation during implantation. This study aims to overcome this problem by using a unique process without refraining from biocompatibility. Accordingly, a titanium film with 1 µm thickness was deposited on 316 LVM stainless-steel sheets using magnetron sputtering. Then, the samples were anodized to produce nanoporous oxide. The nanoporous oxide was removed by ultrasonication, leaving an approximately 500 nm metallic titanium layer with a nanopatterned surface. XPS studies revealed the presence of a 5 nm-thick TiO2 surface layer with a trace amount of fluorinated titanium on nanopatterned surfaces. Oxygen plasma treatment of the nanopatterned surface produced an additional 5 nm-thick fluoride-free oxide layer. The samples did not exhibit any cracking or spallation during plastic deformation. Cell viability studies showed that nanopatterned surfaces stimulate endothelial cell proliferation while reducing the proliferation of smooth muscle cells. Plasma treatment further accelerated the proliferation of endothelial cells. Activation of blood platelets did not occur on oxygen plasma-treated, fluoride-free nanopatterned surfaces. The presented surface treatment method can also be applied to other stent materials such as CoCr, nitinol, and orthopedic implants.
- 21 April 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (9) , 4595
Open AccessBiocompatibility and Mechanical Stability of Nanopatterned Titanium Films on Stainless Steel Vascular Stents
Nanoporous ceramic coatings such as titania are promoted to produce drug-free cardiovascular stents with a low risk of in-stent restenosis (ISR) because of their selectivity towards vascular cell proliferation. The brittle coatings applied on stents are prone to cracking because they are subjected to plastic deformation during implantation. This study aims to overcome this problem by using a unique process without refraining from biocompatibility. Accordingly, a titanium film with 1 µm thickness was deposited on 316 LVM stainless-steel sheets using magnetron sputtering. Then, the samples were anodized to produce nanoporous oxide. The nanoporous oxide was removed by ultrasonication, leaving an approximately 500 nm metallic titanium layer with a nanopatterned surface. XPS studies revealed the presence of a 5 nm-thick TiO2 surface layer with a trace amount of fluorinated titanium on nanopatterned surfaces. Oxygen plasma treatment of the nanopatterned surface produced an additional 5 nm-thick fluoride-free oxide layer. The samples did not exhibit any cracking or spallation during plastic deformation. Cell viability studies showed that nanopatterned surfaces stimulate endothelial cell proliferation while reducing the proliferation of smooth muscle cells. Plasma treatment further accelerated the proliferation of endothelial cells. Activation of blood platelets did not occur on oxygen plasma-treated, fluoride-free nanopatterned surfaces. The presented surface treatment method can also be applied to other stent materials such as CoCr, nitinol, and orthopedic implants.
- 1 August 2017
- Published by Elsevier in Surface and Coatings Technology
- Vol. 322, 211-217
The role of droplets on the cavitation erosion damage of TiN coatings produced with cathodic arc physical vapor deposition
- 1 August 2017
- Published by Elsevier in Surface and Coatings Technology
- Vol. 322, 211-217
The role of droplets on the cavitation erosion damage of TiN coatings produced with cathodic arc physical vapor deposition