SKShalen Kumar

Shalen Kumar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shalen Kumar has a total of 41 co-authors. Here are the top co-authors by number of shared publications:

  • Bingjie Zou

    Key Laboratory of Drug Quality Control and Pharmacovigilance Ministry of Education, School of Pharmacy China Phar‐maceutical University Nanjing 210009 China

    4 shared publications
  • Guohua Zhou

    Department of Clinical Pharmacy, Jinling Hospital, Affiliated Hospital of Medical School, Nanjing University, Nanjing, 210002, China

    4 shared publications
  • Janet L. Pitman

    School of Biological Sciences, Victoria University of Wellington, Wellington, 6140, New Zealand

    4 shared publications
  • Justin M. Hodgkiss

    School of Chemical and Physical Sciences, Victoria University of Wellington, Wellington 6012, New Zealand

    4 shared publications
  • Omar A. Alsager

    King Abdulaziz City for Science and Technology , Riyadh 12371, Saudi Arabia

    4 shared publications
  • Qinxin Song

    Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, School of Pharmacy, China Pharmaceutical University, Nanjing, China

    3 shared publications

Latest Publications

  • Open Access

    A Review of Osmotic Pump Applications as a Reliable Drug Delivery System in Pharmaceutical Sciences

    by Samar Mahari, Seydeh Halimeh Najafi, Salar Masoomzadeh, Shalen Kumar, Tooba Gholikhani

    Systems known in the pharmaceutical sciences have less use for drug release and control. In addition, these standard systems in pharmacy have no effective control over drug concentrations. The main problem with conventional drug delivery systems (DDS) is the unpredictability of different plasma concentrations. However, drug control systems have provided an excellent way to release the drug. In this regard, osmotic pumps are the best and most promising systems for the controlled delivery and release of drugs. They are commonly used for oral and injectable use, several of which are also commercialized and widely accepted by patients, especially the antihypertensive products. The purpose of this study is to introduce and compare different types of osmotic pumps in pharmacy.


  • The Potential Use of Aptamers in The Process of Drug Development

    by Tooba Gholikhani, Balam Jimenez Brito, Frey Livingston, Shalen Kumar

    Single-stranded nucleic acids can fold and create unique 3-dimensional structures when interacting with other molecules. The unique structure can achieve high specificity and affinity for the particular target. Synthetic oligonucleotide binding agents also known as aptamers are generated through the rational process of Systematic Evolution of Ligands by Exponential Enrichment (SELEX.) As this technology matures it shows increasing promise for use in the field of a therapeutic drug, drug discovery, development, and delivery, and this report seeks to detail how this technology may be applied.


  • Structural Changes of Mercaptohexanol Self-Assembled Monolayers on Gold and Their Influence on Impedimetric Aptamer Sensors

    by Xingxing Xu, Asta Makaraviciute, Shalen Kumar, Chenyu Wen, Martin Sjödin, Eldar Abdurakhmanov, U. Helena Danielson, Leif Nyholm, Zhen Zhang

    Despite a large number of publications describing biosensors based on electrochemical impedance spectroscopy (EIS), little attention has been paid to the stability and reproducibility issues of the sensor interfaces. In this work, the stability and reproducibility of faradaic EIS analyses on the aptamer/mercaptohexanol (MCH) self-assembled monolayer (SAM) functionalized gold surfaces in ferri- and ferrocyanide solution were systematically evaluated prior to and after the aptamer-probe DNA hybridization. It is shown that the EIS data exhibited significant drift, and this significantly affected the reproducibility of the EIS signal of the hybridization. As a result, no significant difference between the charge transfer resistance (RCT) changes induced by the aptamer-target DNA hybridization and that caused by the drift could be identified. A conditioning of the electrode in the measurement solution for more than 12 hours was required to reach a stable RCT baseline prior to the aptamer-probe DNA hybridization. The monitored drift in RCT and CDL during the conditioning suggests that the MCH SAM on the gold surface reorganized to a thinner but more closely packed layer. We also observed that that the hot binding buffer used in the following aptamer-probe DNA hybridization process could induce additional MCH and aptamer reorganization thus further drift in RCT. As a result, the RCT change caused by the aptamer-probe DNA hybridization was less than that caused by the hot binding buffer (blank control experiment). Therefore, it is suggested that the use of high temperature in the EIS measurement should be carefully evaluated or avoided. This work provides practical guidelines for the EIS measurements. Moreover, since SAM functionalized gold electrodes are widely used in biosensors, e.g., DNA sensors, an improved understanding of the origin of the observed drift is very important for the development of well-functioning and reproducible biosensors.


  • Highly sensitive and specific real-time PCR by employing serial invasive reaction as a sequence identifier for quantifying EGFR mutation abundance in cfDNA

    by Zheng Xiang, Ruixuan Wan, Bingjie Zou, Xiemin Qi, Qing Huang, Shalen Kumar, Janet L. Pitman, Guohua Zhou, Qinxin Song

    Detection of EGFR mutations in circulating cell-free DNA (cfDNA) is beneficial to monitor the therapeutic effect, tumor progression, and drug resistance in real time. However, it requires that the mutation detection method has the ability to quantify the mutation abundance accurately. Although the next-generation sequencing (NGS) and digital PCR showed high sensitivity for quantifying mutations in cfDNA, the use of expensive equipment and the high-cost hampered their applications in the clinic. Herein, we propose a highly sensitive and specific real-time PCR by employing serial invasive reaction as a sequence identifier for quantifying EGFR mutation abundance in cfDNA (termed as qPCR-Invader). The mutation abundance can be quantified by using the difference of Ct values between mutant and wild-type targets without the need of making a standard curve. The method can quantify a mutation level as lower as 0.1% (10 copies/tube). Thirty-six tissue samples from non-small-cell lung cancer (NSCLC) patients were detected by our method and 14/36 tissues gave EGFR L858R mutation-positive results, whereas ARMS-PCR just identified 12 of L858R mutant samples. The two inconsistent samples were confirmed as L858R mutant by pyrophosphorolysis-activated polymerization method, indicating that qPCR-Invader is more sensitive than ARMS-PCR for mutation detection. The L858R mutation abundances of 19 cfDNA samples detected by qPCR-Invader were close to that from NGS, indicating our method can precisely quantify mutation abundance in cfDNA. The qPCR-Invader just needs a common real-time PCR device to accomplish quantification of EGFR mutations, and the fluorescence probes are universal for any target detection. Therefore, it could be used in most laboratories to analyze mutations in cfDNA.


  • Lateral Flow Aptasensor for Small Molecule Targets Exploiting Adsorption and Desorption Interactions on Gold Nanoparticles

    by Omar A. Alsager, Shalen Kumar, Justin M. Hodgkiss

    A lateral flow assay (LFA) can provide a rapid and cost-effective means to detect targets in situ; however, existing LFA formats (predominantly sandwich assays) are not suitable for small molecule targets. We present a new LFA design that probes the dissociation of aptamers from the surface of gold nanoparticles upon recognition of small targets. The target-induced removal of aptamer molecules from the surface of the colored particles results in the particles being captured on a test line comprised of the protein bovine serum albumin immobilized on nitrocellulose. On the other hand, in the absence of target, aptamer coated particles are protected from capture on the test line and are instead captured at a control line comprised of the protein lysozyme. This protein is strongly positively charged under measurement conditions and therefore captures all gold nanoparticles regardless of the presence of aptamers. The effectiveness and operation mechanism of this simply fabricated sensor was demonstrated by using a previously reported 35-mer aptamer for a small molecule, 17β-estradiol. The sensor exhibited nanomolar level of detection, excellent selectivity against potential interfering molecules, and robust operation in natural river water samples. The simplicity and performance of the sensor platform renders it applicable to a wide range of other aptamers targeting small molecules, as we demonstrated with a novel bisphenol A aptamer. Additionally, we show that our LFA design is not confined to the specific proteins used as test and control lines, provided that their charge is appropriate to modulate the interaction with aptamer-coated or bare nanoparticles.


  • Signal amplification of microRNAs with modified strand displacement-based cycling probe technology

    by Huning Jia, Ying Bu, Bingjie Zou, Jianping Wang, Shalen Kumar, Janet L. Pitman, Guohua Zhou, Qinxin Song

    Micro ribose nucleic acids (miRNAs) play an important role in biological processes such as cell differentiation, proliferation and apoptosis.


  • Prenatal diagnosis of trisomy 21, 18 and 13 by quantitative pyrosequencing of segmental duplications

    by Huan Tong, Yiru Jin, Yinqiu Xu, Bingjie Zou, Hui Ye, Haiping Wu, Shalen Kumar, Janet L. Pitman, Guohua Zhou, Qinxin Song

    Chromosomal aberration mostly occurs in chromosomes 21, 18 and 13, with an incidence approximately 1 out of 160 live births in humans, therefore making prenatal diagnosis necessary in clinics. Current methods have drawbacks such as time consuming, high cost, complicated operations and low sensitivity. In this paper, a novel method for rapid and accurate prenatal diagnosis of aneuploidy is proposed based on pyrosequencing, which quantitatively detects the peak height ratio (PHR) of different bases of segmental duplication. A direct polymerase chain reaction (PCR) approach was undertaken, where a small volume of amniotic fluid was used as the starting material without DNA extraction. Single‐stranded DNA was prepared from PCR products and subsequently analyzed using pyrosequencing. The PHR between target and reference chromosome of 2.2 for euploid and 3:2 for a trisomy fetus were used as reference. The reference intervals and z scores were calculated for discrimination of aneuploidy. A total of 132 samples were collected, within trisomy 21 (n = 11), trisomy 18 (n = 3), trisomy 13 (n = 2), and unaffected controls (n = 116). A set of six segmental duplications were chosen for analysis. This method had consistent results with karyotyping analysis, a correct diagnosis with 100% sensitivity and 99.9% specificity.


  • Invader Assisted Enzyme-Linked Immunosorbent Assay for Colorimetric Detection of Disease Biomarkers Using Oligonucleotide Probe-Modified Gold Nanoparticles

    by Qinxin Song, Xiemin Qi, Huning Jia, Liang He, Shalen Kumar, Janet L. Pitman, Bingjie Zou, Guohua Zhou

    We successfully developed an invader assisted ELISA assay (iaELISA) for sensitive detection of disease biomarkers. The method includes three key steps as follows; biotinylated detection antibody was at first used to capture targeted antigen by sandwich ELISA. The biotinylated oligonucleotide was then attached to detection antibody via streptavidin. Finally, the cascade invader reactions were employed to amplify the biotinylated oligonucleotide specific to the antigen so that detection of the antigen was transformed into signal amplification of the antigen-specific DNA. To achieve colorimetric detection, oligonucleotide probe and modified gold nanoparticles (AuNPs) were coupled with the invader assay. Utilization of the hairpin probes in the invader reaction brought about free AuNPs, resulting in the positive read-out (red color). On the other hand, aggregation of the AuNPs occurred when the hairpin probes were not utilized in the reaction. This method was successfully used to detect as low as 2.4 x 10(-11) g/mL of HBsAg by both naked eye and spectrophotometer. This sensitivity was about 100 times higher than that of conventional ELISA method. The method was also used to assay 16 serum specimens from HBV-infected patients and 8 serum specimens from HBV-negative donors and results were in good agreement with those obtained from the conventional ELISA. As the invader assay is sensitive to one base sequence, a good specificity was also obtained by detecting other antigens like hepatitis A virus (HAV) and BSA. The method has therefore much potential for ultrasensitive and cost-effective detection of targeted proteins that have clinical importance.


  • Label-free electrochemical aptasensor for femtomolar detection of 17β-estradiol

    by Bicheng Zhu, Omar A. Alsager, Shalen Kumar, Justin M. Hodgkiss, Jadranka Travas-Sejdic


  • Ultrasensitive Colorimetric Detection of 17β-Estradiol: The Effect of Shortening DNA Aptamer Sequences

    by Omar A. Alsager, Shalen Kumar, Bicheng Zhu, Jadranka Travas-Sejdic, Kenneth P. McNatty, Justin M. Hodgkiss

    We report a strategy enabling ultrasensitive colorimetric detection of 17β-estradiol (E2) in water and urine samples using DNA aptamer-coated gold nanoparticles (AuNPs). Starting from an established sensor format where aggregation is triggered when target-bound aptamers dissociate from AuNP surfaces, we demonstrated that step-change improvements are easily accessible through deletion of excess flanking nucleotides from aptamer sequences. After evaluating the lowest energy two-dimensional configuration of the previously isolated E2 binding 75-mer aptamer (KD ∼25 nM), new 35-mer and 22-mer aptamers were generated with KD’s of 14 and 11 nM by simply removing flanking nucleotides on either side of the inner core. The shorter aptamers were found to improve discrimination against other steroidal molecules and to improve colorimetric sensitivity for E2 detection by 25-fold compared with the 75-mer to 200 pM. In comparing the response of all sequences, we find that the excess flanking nucleotides suppress signal transduction by causing target-bound aptamers to remain adhered to AuNPs, which we confirm via surface sensitive electrochemical measurements. However, comparison between the 22-mer and 35-mer systems show that retaining a small number of excess bases is optimal. The performance advances we achieved by specifically considering the signal transduction mechanism ultimately resulted in facile detection of E2 in urine, as well as enabling environmental detection of E2 at levels approaching biological relevance.