Zhi-Gang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Zhi-Gang Li has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Fen Cao
Chinese Academy of Sciences,National Time Service Center,Xian,China
3 shared publications - Pei Wei
National Time Service Center, Chinese Academy of Sciences, Xi’an 710600, China
3 shared publications - Liang Chen
National Time Service Center and the Key Laboratory of Precise Positioning and Timing Technology, Chinese Academy of Sciences, Xian, China
2 shared publications - Weichao Li
National Time Service Center and the Key Laboratory of Precise Positioning and Timing Technology, Chinese Academy of Sciences, Xian, China
2 shared publications - Xuhai Yang
University of Chinese Academy of Sciences, Beijing, 100049, China
2 shared publications - Chaozhong Yang
National Time Service Center, Chinese Academy of Sciences, Xi’an 710600, China
1 shared publication
Latest Publications
- Open Access
- 11 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 14038-14047
Research on Evaluation Method of Time Transfer Performance Between Ground Stations in Two-Way Satellite Comparison Network
High-precision time synchronization between ground stations is essential for the precise measurement and determination of satellite orbits. Among the numerous time synchronization methods available, two-way satellite time and frequency transfer (TWSTFT) technology is widely used because of the approximate symmetry of its signal transmission path, such that most of the error terms can be offset to obtain subnanosecond time transmission accuracy. A C-band two-way satellite comparison network has been constructed at National Time Service Center (NTSC), Chinese Academy of Sciences for orbit determination and to compare the times between ground stations. The gradual increase in the number of ground stations has created a problem in need of urgent resolution: the facile and rapid evaluation of the time transfer performance between ground stations by a two-way satellite comparison network without the use of additional equipment. We solve this problem by applying the TWSTFT triangle closure method and the precise point positioning time transfer method to the NTSC two-way satellite comparison network and conduct joint observations between terrestrial stations to evaluate the network time transfer performance. We select the Xi’an, Kashi and Sanya stations of the NTSC two-way satellite comparison network to carry out verification tests. The results show that the NTSC two-way satellite comparison network can achieve subnanosecond time synchronization accuracy. The accuracy of time synchronization between stations can be checked conveniently and quickly without the use of additional equipment. This study presents the most recent developments for the NTSC two-way satellite comparison network and serves as a reference for evaluating the time transfer performance of similar networks.
- 11 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 14038-14047
Open AccessResearch on Evaluation Method of Time Transfer Performance Between Ground Stations in Two-Way Satellite Comparison Network
High-precision time synchronization between ground stations is essential for the precise measurement and determination of satellite orbits. Among the numerous time synchronization methods available, two-way satellite time and frequency transfer (TWSTFT) technology is widely used because of the approximate symmetry of its signal transmission path, such that most of the error terms can be offset to obtain subnanosecond time transmission accuracy. A C-band two-way satellite comparison network has been constructed at National Time Service Center (NTSC), Chinese Academy of Sciences for orbit determination and to compare the times between ground stations. The gradual increase in the number of ground stations has created a problem in need of urgent resolution: the facile and rapid evaluation of the time transfer performance between ground stations by a two-way satellite comparison network without the use of additional equipment. We solve this problem by applying the TWSTFT triangle closure method and the precise point positioning time transfer method to the NTSC two-way satellite comparison network and conduct joint observations between terrestrial stations to evaluate the network time transfer performance. We select the Xi’an, Kashi and Sanya stations of the NTSC two-way satellite comparison network to carry out verification tests. The results show that the NTSC two-way satellite comparison network can achieve subnanosecond time synchronization accuracy. The accuracy of time synchronization between stations can be checked conveniently and quickly without the use of additional equipment. This study presents the most recent developments for the NTSC two-way satellite comparison network and serves as a reference for evaluating the time transfer performance of similar networks.
- 17 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (9) , 1938-1945
Common-View Time Transfer Using Geostationary Satellite
The National Time Service Center (NTSC), Chinese Academy of Sciences (CAS) has developed a method for Common-View time transfer using Geostationary Earth Orbit (GEO) satellite (GCV) applicable the time and frequency transfer at distant stations. This method is independent of GNSS time and frequency transfer, as well as Two-Way Satellite Time and Frequency Transfer (TWSTFT). A master clock at the time laboratory transmits pseudorandom code signals to a GEO telecommunication satellite, and the time signals is retransmitted by the satellite. Receivers at the time laboratory and user locations coincidentally receive the time signals, and the offsets between the user clocks and the master clock of the time laboratory are determined with high precision if the precise coordinates of the user locations are known. For this technology, only a parabolic antenna with receiver devices and a demodulator are required at each user station, but the coordinates and precise orbits need to be obtained in advance. The key features of GCV include a. continuous coverage of the signal from GEO communication satellites; b. differential observations to reduce the effects of orbit error and the imprecision of the propagation delay model; c. using a Very Small Aperture Terminal (VSAT) to enhance high Signal ratio to noise to obtain precise ranging accuracy and anti-multipath ability; and d. utilizing the C band or Ku band to decrease the impact of the ionosphere. Experiments based on the TWSTFT network of CAS showed that the performance of GCV was at the same level as that of TWSTFT, and the RMS of the residuals of GCV was less than 1.5 ns with respect to TWSTFT.
- 17 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 67 (9) , 1938-1945
Common-View Time Transfer Using Geostationary Satellite
The National Time Service Center (NTSC), Chinese Academy of Sciences (CAS) has developed a method for Common-View time transfer using Geostationary Earth Orbit (GEO) satellite (GCV) applicable the time and frequency transfer at distant stations. This method is independent of GNSS time and frequency transfer, as well as Two-Way Satellite Time and Frequency Transfer (TWSTFT). A master clock at the time laboratory transmits pseudorandom code signals to a GEO telecommunication satellite, and the time signals is retransmitted by the satellite. Receivers at the time laboratory and user locations coincidentally receive the time signals, and the offsets between the user clocks and the master clock of the time laboratory are determined with high precision if the precise coordinates of the user locations are known. For this technology, only a parabolic antenna with receiver devices and a demodulator are required at each user station, but the coordinates and precise orbits need to be obtained in advance. The key features of GCV include a. continuous coverage of the signal from GEO communication satellites; b. differential observations to reduce the effects of orbit error and the imprecision of the propagation delay model; c. using a Very Small Aperture Terminal (VSAT) to enhance high Signal ratio to noise to obtain precise ranging accuracy and anti-multipath ability; and d. utilizing the C band or Ku band to decrease the impact of the ionosphere. Experiments based on the TWSTFT network of CAS showed that the performance of GCV was at the same level as that of TWSTFT, and the RMS of the residuals of GCV was less than 1.5 ns with respect to TWSTFT.
- 30 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (8) , 1475-1486
An Improved Protocol for Performing Two-Way Satellite Time and Frequency Transfer Using a Satellite in an Inclined Geo-Synchronous Orbit
Two-way satellite time and frequency transfer (TWSTFT) using satellites in inclined geo-synchronous orbit (IGSO) is fundamentally more difficult than using satellites in geostationary orbit (GEO), due to the fact that IGSO satellites are constantly moving relative to a ground station, which brings in large residual effects. In this paper, we designed a protocol and an algorithm to correct several factors that affect the precision of TWSTFT using IGSO satellites. We used two ground stations, each equipped with sending and receiving channels, to conduct real-time measurements of the distance and the speed of an IGSO satellite, and data collected were used to make appropriate corrections. We tested this concept by conducting TWSTFT experiments using an IGSO satellite (BEIDOU I1-S), and compared the results with that obtained using a GEO satellite (CHINASAT 12). Indeed, the individual components that contribute to the residual effects of TWSTFT measurements using the IGSO satellite were several orders of magnitude greater than that of the GEO satellite. By using our modified protocol, TWSTFT results with an IGSO satellite were well accorded with that of using a GEO satellite; the standard deviation of residuals was less than 0.4 ns, well within the limit for the measurement uncertainty of TWSTFT. Therefore, we have expanded the use of IGSO satellites for TWSTFT. In principle, it should also be applicable to medium earth orbit and other satellites.
- 30 May 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (8) , 1475-1486
An Improved Protocol for Performing Two-Way Satellite Time and Frequency Transfer Using a Satellite in an Inclined Geo-Synchronous Orbit
Two-way satellite time and frequency transfer (TWSTFT) using satellites in inclined geo-synchronous orbit (IGSO) is fundamentally more difficult than using satellites in geostationary orbit (GEO), due to the fact that IGSO satellites are constantly moving relative to a ground station, which brings in large residual effects. In this paper, we designed a protocol and an algorithm to correct several factors that affect the precision of TWSTFT using IGSO satellites. We used two ground stations, each equipped with sending and receiving channels, to conduct real-time measurements of the distance and the speed of an IGSO satellite, and data collected were used to make appropriate corrections. We tested this concept by conducting TWSTFT experiments using an IGSO satellite (BEIDOU I1-S), and compared the results with that obtained using a GEO satellite (CHINASAT 12). Indeed, the individual components that contribute to the residual effects of TWSTFT measurements using the IGSO satellite were several orders of magnitude greater than that of the GEO satellite. By using our modified protocol, TWSTFT results with an IGSO satellite were well accorded with that of using a GEO satellite; the standard deviation of residuals was less than 0.4 ns, well within the limit for the measurement uncertainty of TWSTFT. Therefore, we have expanded the use of IGSO satellites for TWSTFT. In principle, it should also be applicable to medium earth orbit and other satellites.