RWRichard Westreich

Richard Westreich

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Richard Westreich has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • William Lawson

    Departments of Otolarynogology (Drs Westreich and Lawson) and Anesthesiology (Dr Sampson), Mount Sinai Hospital, New York, NY; and Division of Head and Neck Cancer, The Cancer Center at Hackensack University Medical Center, Hackensack, NJ (Dr Shaari)

    3 shared publications
  • Christopher M. Shaari

    Departments of Otolarynogology (Drs Westreich and Lawson) and Anesthesiology (Dr Sampson), Mount Sinai Hospital, New York, NY; and Division of Head and Neck Cancer, The Cancer Center at Hackensack University Medical Center, Hackensack, NJ (Dr Shaari)

    1 shared publication
  • Donald A. Bergman

    Department of Endocrinology, Mount Sinai Hospital, New York, NY, U.S.A.

    1 shared publication
  • Ian Sampson

    Departments of Otolarynogology (Drs Westreich and Lawson) and Anesthesiology (Dr Sampson), Mount Sinai Hospital, New York, NY; and Division of Head and Neck Cancer, The Cancer Center at Hackensack University Medical Center, Hackensack, NJ (Dr Shaari)

    1 shared publication
  • Jeffrey I. Mechanick

    Department of Endocrinology, Mount Sinai Hospital, New York, NY, U.S.A.

    1 shared publication
  • M Kaufman

    Department of Otolaryngology, Mount Sinai Hospital, New York, New York, U.S.A.

    1 shared publication

Latest Publications

  • Negative-Pressure Pulmonary Edema After Routine Septorhinoplasty

    by Richard Westreich, Ian Sampson, Christopher M. Shaari, William Lawson

    Opinion from JAMA Facial Plastic Surgery — Negative-Pressure Pulmonary Edema After Routine Septorhinoplasty — Discussion of Pathophysiology, Treatment, and Prevention


  • Perforating Double Lateral Osteotomy

    by Richard W. Westreich, William Lawson

    Reshaping of the bony vault in primary and revision rhinoplasty is a simple, yet precise, maneuver that requires both skill and experience in creating predictable outcomes. Different methods for re...


  • Validating the Subcutaneous Model of Injectable Autologous Cartilage Using a Fibrin Glue Scaffold

    by R Westreich, M Kaufman, P Gannon, W Lawson

    Purpose: To create and validate an injectable model for autologous in vivo cartilage engineering with ultimate clinical applicability in human subjects.Hypothesis: Cartilage can be generated subcutaneously using fibrin glue and autologous chondrocyte components.Background: To date, cartilage engineering studies have been limited by several factors. Immunocompromised animals and nonautologous chondrocytes have been successfully used to create cartilage, but results using identical designs failed in immunocompetent subjects. Recent studies using more biocompatible tissues and matrices have been performed with both in vitro and in vivo steps. Although successful, several problems are notable. In vitro cartilage displays a poor modulus of elasticity, even after in vivo implantation. Variable deformation and volume loss occurs when in vitro specimens are matured in vivo. These concerns limit the clinical utility of these methods. We therefore set out to create autologous cartilage using a model that was clinically feasible, easy to create, and could be performed with very low patient harvest morbidity.Materials and Methods: Eight New Zealand white rabbits underwent a unilateral harvest of ear cartilage. Samples were then digested using standard methods. Cell counts and survival assays were performed before implantation. One sample of fibrin glue (Tisseel) and chondrocytes was injected subcutaneously into each donor rabbit and then left in situ for 3 months. A second sample with both basic fibroblast growth factor (b‐FGF) and insulin‐like growth factor (IGF)‐1 in the injection suspension was also assessed (for a total of 16 samples). After harvest, analysis of overall volume, histology, and chondrocyte drop out counts was performed.Results: Cartilage formation occurred in 8 of 14 (57%) specimens that were obtained at the time of sacrifice. Of note, 6 of 7 (85%) non–growth‐factor containing samples yielded positive results. Comparison with the success rate using concomitant growth factors (2/7) showed a negative effect on cartilage yield (P = .015). Chondrocyte survival, based on chondrocyte dropout counts, was not effected. Angiogenesis appeared to correlate with cartilage formation in the central regions of the implant. Alcian blue demonstrated the presence of active matrix deposition, and elastin Verhoff‐van Geison (EVG) stains were positive, showing an elastic cartilage phenotype. Very limited osteoid formation was seen in successful implants. Failed implants demonstrated avascular necrosis, giant cell reactions, and inflammatory infiltrates.Conclusions: This study validates the subcutaneous site as a recipient bed for the engineering of autologous cartilage in vivo. It also represents the first subcutaneous implantation of fibrin glue and chondrocytes in an immunocompetent host as well as the first published report of elastic cartilage generation in vivo. Although the model needs to be further streamlined to increase yields and overall volume, this study clearly demonstrates the feasibility of in vivo chondrogenesis (85% success). The addition of FGF and IGF‐1 at the concentrations used negatively influenced cartilage yield. However, extrapolation of these results to other combinations or concentrations can not be done, and this issue deserves further investigation.


  • Preoperative Parathyroid Localization: Correlating False‐Negative Technetium 99m Sestamibi Scans With Parathyroid Disease

    by Richard W. Westreich, Margaret Brandwein, Jeffrey I. Mechanick, Donald A. Bergman, Mark L. Urken

    Objective/Hypothesis The recent trend toward minimally invasive directed parathyroid surgery has increased the surgeon's reliance on preoperative parathyroid localization. Technetium Tc 99m sestamibi...