OAOliver Franz Adunka

Oliver Franz Adunka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Oliver Franz Adunka has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Craig A. Buchman

    Department of Otolaryngology/Head and Neck Surgery, The University of North Carolina at Chapel Hill; Chapel Hill North Carolina, U.S.A.

    6 shared publications
  • Baishakhi Choudhury

    Department of Otolaryngology/Head and Neck Surgery, The University of North Carolina at Chapel Hill; Chapel Hill North Carolina, U.S.A.

    3 shared publications
  • Douglas C. Fitzpatrick

    Department of Otolaryngology/Head and Neck Surgery, The University of North Carolina at Chapel Hill; Chapel Hill North Carolina, U.S.A.

    3 shared publications
  • Margaret T. Dillon

    Department of Otolaryngology/Head and Neck Surgery University of North Carolina at Chapel Hill North Carolina U.S.A

    2 shared publications
  • Adam P. Campbell

    University of North Carolina at Chapel Hill

    1 shared publication
  • Adam T. Campbell

    Department of Otolaryngology/Head and Neck Surgery, The University of North Carolina at Chapel Hill; Chapel Hill, North Carolina, U.S.A.

    1 shared publication

Latest Publications

  • Electrophysiologic Consequences of Flexible Electrode Insertions in Gerbils With Noise-Induced Hearing Loss

    by Baishakhi Choudhury, Oliver Franz Adunka, Omar Awan, John Maxwell Pike, Craig A. Buchman, Douglas C. Fitzpatrick

    Hypothesis Flexible electrode interaction with intracochlear structures in a noise-damaged region of the cochlea can lead to measureable electrophysiologic changes. Background An emerging goal in cochlear implantation is preservation of residual hearing subsequently allowing for combined electric and acoustic stimulation (EAS). However, residual hearing is at least partially lost in most patients as a result of electrode insertion. A gerbil model was used to examine changes to acoustically evoked cochlear potentials during simulated cochlear implantation. Methods Gerbils were partially deafened by noise exposure to mimic residual hearing in human cochlear implant candidates. After 1 month, round window and intracochlear recordings during flexible electrode insertion were made in response to 1 kHz tone burst stimuli at 80 dB SPL. After the insertion, the cochleas were histologically examined for hair cell loss because of the noise exposure and trauma because of the electrode insertion. Results Anatomic damage from the flexible electrode was not observable in most cases. However, insertions caused response declines that were, on average, greater than the controls, although some losses were similar to the controls. The CM was more sensitive than the CAP for detecting cochlear disturbance. Conclusion Because response reductions occurred in the absence of anatomic damage, disturbances in the fluid at the base appear to affect responses from the apex. The losses were less than in previous experiments where the basilar membrane was penetrated.


  • Round Window Electrocochleography Just Before Cochlear Implantation

    by Douglas C. Fitzpatrick, Adam T. Campbell, Baishakhi Choudhury, Margaret P. Dillon, Mathieu Forgues, Craig A. Buchman, Oliver F. Adunka

    Hypotheses Electrocochleography (ECoG) to acoustic stimuli can differentiate relative degrees of cochlear responsiveness across the population of cochlear implant recipients. The magnitude of the ongoing portion of the ECoG, which includes both hair cell and neural contributions, will correlate with speech outcomes as measured by results on CNC word score tests. Background Postoperative speech outcomes with cochlear implants vary from almost no benefit to near normal comprehension. A factor expected to have a high predictive value is the degree of neural survival. However, speech performance with the implant does not correlate with the number and distribution of surviving ganglion cells when measured postmortem. We will investigate whether ECoG can provide an estimate of cochlear function that helps predict postoperative speech outcomes. Methods An electrode was placed at the round window of the ear about to be implanted during implant surgery. Tone bursts were delivered through an insert earphone. Subjects included children (n = 52, 1–18 yr) and postlingually hearing impaired adults (n = 32). Word scores at 6 months were available from 21 adult subjects. Results Significant responses to sound were recorded from almost all subjects (80/84 or 95%). The ECoG magnitudes spanned more than 50 dB in both children and adults. The distributions of ECoG magnitudes and frequencies were similar between children and adults. The correlation between the ECoG magnitude and word score accounted for 47% of the variance. Conclusion ECoGs with high signal-to-noise ratios can be recorded from almost all implant candidates, including both adult and pediatric populations. In postlingual adults, the ECoG magnitude is more predictive of implant outcomes than other nonsurgical variables such as duration of deafness or degree of residual hearing.


  • Hearing preservation and speech perception outcomes with electric‐acoustic stimulation after 12 months of listening experience

    by Oliver F. Adunka, Margaret T. Dillon, Marcia C. Adunka, English R. King, Harold C. Pillsbury, Craig A. Buchman

    Objectives/Hypothesis: To report on single‐center data of an FDA‐approved clinical trial on the objective benefits of cochlear implantation and subsequent ipsilateral Electric‐Acoustic Stimulation (EAS).Study Design: Single‐center data from a prospective, multicenter clinical trial.Methods: Eighteen subjects completed the 12‐month EAS evaluation and were included in this evaluation. Each patient underwent cochlear implantation using a standardized hearing preservation approach. Both hearing preservation and speech perception abilities were evaluated at various intervals. Speech testing included performance measures obtained in quiet (CNC words) and noise (adaptive CUNY protocol) in three listening conditions: hearing aid (HA) alone, cochlear implant (CI) only, and combined ipsilateral EAS.Results: Various levels of hearing preservation were achieved with cochleostomy and round‐window surgical approaches in 17 of the 18 subjects. Mean CNC word scores at the 12‐month interval were 14.9 ± 12.1, 45.3 ± 15.4, and 70.7 ± 11.7% correct in the HA only, CI only, and EAS conditions, respectively. Average CUNY scores at 0 dB SNR were 14.6 ± 17.2, 47.1 ± 22.1, and 72.2 ± 21.5 for the three test conditions obtained after 12 months.Conclusions: Data obtained during this clinical trial correlate well with previous reports. Hearing preservation appears successful in a high number of subjects, and combined EAS offers excellent speech perception abilities in quiet and in noise. Laryngoscope, 123:2509–2515, 2013


  • Hearing Preservation Cochlear Implantation

    by Adam P. Campbell, Margaret T. Dillon, Craig A. Buchman, Oliver F. Adunka


  • Influence of an Intraoperative Perilymph Gusher on Cochlear Implant Performance in Children With Labyrinthine Malformations

    by Oliver Franz Adunka, Holly F. B. Teagle, Carlton J. Zdanski, Craig A. Buchman

    To assess the effect of an intraoperative perilymph fluid gusher during cochlear implantation on speech perception abilities in pediatric patients with labyrinthine anomalies. Tertiary care academic referral center. Seventy subjects with labyrinthine malformations who received a cochlear implant were identified in our pediatric cochlear implant database. In 30 cases, an intraoperative perilymph fluid gusher was encountered during surgery. Fifteen children with GJB2 positive hereditary hearing loss served as controls. Multiple speech perception measures were obtained with the cochlear implant. The best score for each subject over time was determined as a speech reception index in quiet. This index was compared among groups and malformation types. The speech reception index in quiet demonstrated overall good performance scores of cochlear implantation in children with incomplete partitioning/enlarged vestibular aqueduct type malformations. Children with hypoplastic malformations, on the other hand, showed variable outcomes with many children demonstrating only limited long-term speech discrimination abilities. The presence or absence of a perilymph gusher did not significantly influence results after cochlear implantation. This report documents the variable outcomes of pediatric cochlear implantation in children with inner ear malformations. More importantly, anatomic parameters, such as the classification of the anomaly and the presence of a viable cochlear nerve, seem to influence performance measures substantially. The presence of a perilymph gusher did not influence outcomes in both hypoplastic and incomplete partitioning/enlarged vestibular aqueduct type malformations. 2b Individual retrospective cohort study.


  • Detection of Intracochlear Damage With Cochlear Implantation in a Gerbil Model of Hearing Loss

    by Baishakhi Choudhury, Oliver Franz Adunka, Christine E. DeMason, Faisal I. Ahmad, Craig A. Buchman, Douglas C. Fitzpatrick

    Hypothesis: Cochlear trauma due to electrode insertion can be detected in acoustic responses to low frequencies in an animal model with a hearing condition similar to patients using electroacoustic stimulation. Background: Clinical evidence suggests that intracochlear damage during cochlear implantation negatively affects residual hearing. Recently, we demonstrated the usefulness of acoustically evoked potentials to detect cochlear trauma in normal-hearing gerbils. Here, gerbils with noise-induced hearing loss were used to investigate the effects of remote trauma on residual hearing. Methods: Gerbils underwent high-pass (4-kHz cutoff) noise exposure to produce sloping hearing loss. After 1 month of recovery, each animal's hearing loss was determined from auditory brainstem responses and baseline intracochlear recording of the cochlear microphonic and compound action potential (CAP) obtained at the round window. Subsequently, electrode insertions were performed to produce basal trauma, whereas the acoustically generated potentials to a 1-kHz tone-burst were recorded after each step of electrode advancement. Hair cell counts were made to characterize the noise damage, and cochlear whole mounts were used to identify cochlear trauma due to the electrode. Results: The noise exposure paradigm produced a pattern of hair cell, auditory brainstem response, and intracochlear potential losses that closely mimicked that of electrical and acoustic stimulation patients. Trauma in the basal turn, in the 15- to 30-kHz portion of the deafened region, remote from preserved hair cells, induced a decline in intracochlear acoustic responses to the hearing preserved frequency of 1 kHz. Conclusion: The results indicate that a recording algorithm based on physiological markers to low-frequency acoustic stimuli can identify cochlear trauma during implantation. Future work will focus on translating these results for use with current cochlear implant technology in humans.