Rajesh Patel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Rajesh Patel has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Hiral Virpura
Department of Physics, Maharaja Krishnakumarsinhji Bhavnagar University, Bhavnagar. 364002. India
2 shared publications - Bhupendra Chudasama
School of Physics and Materials Science, Thapar Institute of Engineering and Technology 2 , Patiala 147004
1 shared publication - J. V. Joshi
UGC- DAE Consortium for Scientific Research, Mumbai Centre, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085, India
1 shared publication M. Parmar
Maharaja Krishnakumarsinhji Bhavnagar University
1 shared publicationMayur Parmar
Department of Physics, Bhavnagar University, Bhavnagar 364001, GJ, India
1 shared publication- Prem Sagar Goyal
Department of Physics, Pillai’s Institute for Information Technology, New Panvel, Mumbai ‐410206
1 shared publication
Latest Publications
- 1 April 2013
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 331, 113-116
Microcapillary flow behavior of magnetic nanofluids in the presence of plate shaped bentonite particles
- 1 April 2013
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 331, 113-116
Microcapillary flow behavior of magnetic nanofluids in the presence of plate shaped bentonite particles
- 10 March 2013
- Published by Springer Nature in Indian Journal of Physics
- Vol. 87 (6) , 551-554
Exponentially reduced ultrasound velocity in CTABr micellar aqueous solution
- 10 March 2013
- Published by Springer Nature in Indian Journal of Physics
- Vol. 87 (6) , 551-554
Exponentially reduced ultrasound velocity in CTABr micellar aqueous solution
- 26 October 2012
- Published by Springer Nature in The European Physical Journal E
- Vol. 35 (10)
Effect of temperature on rotational viscosity in magnetic nano fluids
Flow behavior of magnetic nano fluids with simultaneous effect of magnetic field and temperature is important for its application for cooling devices such as transformer, loud speakers, electronic cooling and for its efficiency in targeted drug delivery and hyperthermia treatment. Using a specially designed horizontal capillary viscometer, temperature-sensitive and non-temperature-sensitive magnetic nano fluids are studied. In both these case the temperature-dependent rotational viscosity decreases, but follows a quite different mechanism. For temperature-sensitive magnetic nano fluids, the reduction in rotational viscosity is due to the temperature dependence of magnetization. Curie temperature (T c ) and pyromagnetic coefficient are extracted from the study. A fluid with low T c and high pyromagnetic coefficient is useful for thermo-sensitive cooling devices and magnetic hyperthermia. For non-temperature-sensitive magnetic nano fluids, reduction in rotational viscosity is due to removal of physisorbed secondary surfactant on the particle because of thermal and frictional effects. This can be a good analogy for removal of drug from the magnetic particles in the case of targeted drug delivery.
- 26 October 2012
- Published by Springer Nature in The European Physical Journal E
- Vol. 35 (10)
Effect of temperature on rotational viscosity in magnetic nano fluids
Flow behavior of magnetic nano fluids with simultaneous effect of magnetic field and temperature is important for its application for cooling devices such as transformer, loud speakers, electronic cooling and for its efficiency in targeted drug delivery and hyperthermia treatment. Using a specially designed horizontal capillary viscometer, temperature-sensitive and non-temperature-sensitive magnetic nano fluids are studied. In both these case the temperature-dependent rotational viscosity decreases, but follows a quite different mechanism. For temperature-sensitive magnetic nano fluids, the reduction in rotational viscosity is due to the temperature dependence of magnetization. Curie temperature (T c ) and pyromagnetic coefficient are extracted from the study. A fluid with low T c and high pyromagnetic coefficient is useful for thermo-sensitive cooling devices and magnetic hyperthermia. For non-temperature-sensitive magnetic nano fluids, reduction in rotational viscosity is due to removal of physisorbed secondary surfactant on the particle because of thermal and frictional effects. This can be a good analogy for removal of drug from the magnetic particles in the case of targeted drug delivery.
- 23 February 2012
- Published by American Physical Society (APS) in Physical Review E
- Vol. 85 (2) , 026316
Effective viscosity of magnetic nanofluids through capillaries
The simultaneous effect of magnetic field and temperature on the capillary viscosity of magnetic nanofluid is an important parameter for a new class of applications such as nanoduct flow, nanomotors, micro- and nanofluidic devices, for transformer cooling, magnetic targeted drug delivery, etc. The effective viscosity of a nanofluid is explained based on the rotation of the particles and the effect of torque on it due to an externally applied magnetic field. Two types of fluids are used here, temperature-sensitive and non-temperature-sensitive magnetic nanofluids. In both types of fluids, decrease in effective viscosity with temperature is observed, but in both cases the mechanism for the decrement is quite different. One is due to temperature dependence of the magnetic moment and the other is due to removal of the secondary surfactant. For temperature-sensitive magnetic nanofluids, a Curie temperature of 80 C is extracted from this study. For non-temperature-sensitive magnetic nanofluids 65 of the secondary surfactant is removed for a change in temperature, 40 C. This is analogous with removal of a drug from magnetic particles for targeted drug delivery. Further, a linear dependence of effective viscosity with different capillary size and (angle between magnetic field and flow direction, [0,/2]) is also observed. This linear dependence can also be a good approximation for the study of magnetic drug targeting, as in the human body the capillaries are of different sizes, and the externally applied magnetic field is not always parallel or perpendicular to the drug flow direction. DOI: http://dx.doi.org/10.1103/PhysRevE.85.026316 ©2012 American Physical Society- 23 February 2012
- Published by American Physical Society (APS) in Physical Review E
- Vol. 85 (2) , 026316
Effective viscosity of magnetic nanofluids through capillaries
The simultaneous effect of magnetic field and temperature on the capillary viscosity of magnetic nanofluid is an important parameter for a new class of applications such as nanoduct flow, nanomotors, micro- and nanofluidic devices, for transformer cooling, magnetic targeted drug delivery, etc. The effective viscosity of a nanofluid is explained based on the rotation of the particles and the effect of torque on it due to an externally applied magnetic field. Two types of fluids are used here, temperature-sensitive and non-temperature-sensitive magnetic nanofluids. In both types of fluids, decrease in effective viscosity with temperature is observed, but in both cases the mechanism for the decrement is quite different. One is due to temperature dependence of the magnetic moment and the other is due to removal of the secondary surfactant. For temperature-sensitive magnetic nanofluids, a Curie temperature of 80 C is extracted from this study. For non-temperature-sensitive magnetic nanofluids 65 of the secondary surfactant is removed for a change in temperature, 40 C. This is analogous with removal of a drug from magnetic particles for targeted drug delivery. Further, a linear dependence of effective viscosity with different capillary size and (angle between magnetic field and flow direction, [0,/2]) is also observed. This linear dependence can also be a good approximation for the study of magnetic drug targeting, as in the human body the capillaries are of different sizes, and the externally applied magnetic field is not always parallel or perpendicular to the drug flow direction. DOI: http://dx.doi.org/10.1103/PhysRevE.85.026316 ©2012 American Physical Society- 18 November 2010
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 323 (6) , 849-856
Macroscopic and microscopic structural integrity in magnetic colloids—cationic micellar solution: Rheology, SANS and magneto-optical study
- 18 November 2010
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 323 (6) , 849-856
Macroscopic and microscopic structural integrity in magnetic colloids—cationic micellar solution: Rheology, SANS and magneto-optical study
- 7 July 2009
- Published by American Physical Society (APS) in Physical Review E
- Vol. 80 (1) , 012401
Hydrodynamics of chains in ferrofluid-based magnetorheological fluids under rotating magnetic field
Ferrofluid-based magnetorheological (MR) fluid is prepared by dispersing micron-size magnetic spheres in a ferrofluid. We report here the mechanism of chain formation in ferrofluid based MR fluid, which is quite different from conventional MR fluid. Some of the nanomagnetic particles of ferrofluid filled inside the microcavities are formed due to association of large particles, and some of them are attached at the end of large particles. Under rotating magnetic field, fragmentation of a single chain into three parts is observed. Two of them are chains of micron-size magnetic particles which are suspended in a ferrofluid, and the third one is the chain of nanomagnetic particles of ferrofluid, which may be the connecting bridge between the two chains of larger magnetic particles. The rupture of a single chain provides evidence for the presence of nanomagnetic particles within the magnetic field-induced chainlike structure in this bidispersed MR fluid.
- 7 July 2009
- Published by American Physical Society (APS) in Physical Review E
- Vol. 80 (1) , 012401
Hydrodynamics of chains in ferrofluid-based magnetorheological fluids under rotating magnetic field
Ferrofluid-based magnetorheological (MR) fluid is prepared by dispersing micron-size magnetic spheres in a ferrofluid. We report here the mechanism of chain formation in ferrofluid based MR fluid, which is quite different from conventional MR fluid. Some of the nanomagnetic particles of ferrofluid filled inside the microcavities are formed due to association of large particles, and some of them are attached at the end of large particles. Under rotating magnetic field, fragmentation of a single chain into three parts is observed. Two of them are chains of micron-size magnetic particles which are suspended in a ferrofluid, and the third one is the chain of nanomagnetic particles of ferrofluid, which may be the connecting bridge between the two chains of larger magnetic particles. The rupture of a single chain provides evidence for the presence of nanomagnetic particles within the magnetic field-induced chainlike structure in this bidispersed MR fluid.