Ichihiro Yamada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ichihiro Yamada has a total of 223 co-authors. Here are the top co-authors by number of shared publications:
- Ryo Yasuhara
National Institute for Fusion Science, Toki, Gifu 509-5292, Japan
13 shared publications H. Funaba
National Institute for Fusion Science, Toki, Gifu 509-5292, Japan
11 shared publications- Naoki Kenmochi
National Institute for Fusion Science, Toki, Japan
9 shared publications - Katsumi Ida
National Institute for Fusion Science, National Institutes of Natural Sciences 1 , Toki 509-5292
8 shared publications - Masayuki Yoshikawa
University of Tsukuba
7 shared publications J. Kohagura
Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
6 shared publications
Latest Publications
- Open Access
- 1 May 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (5)
Enhancement of mid-/high-Z impurity transport by continuous Li-granule dropping in a stellarator plasma
An enhancement of core impurity transport is observed in high-density plasmas of the stellarator large helical device, heated by neutral beam injection, when continuous lithium (Li) granule dropping is performed. In the reported experiments, in which the tracer-encapsulated solid pellet is employed to inject trace amounts of titanium (Ti) and molybdenum (Mo) into the plasma core, confinement times for these impurities are seen to reduce significantly when Li dropping is applied, this reduction being more notable for Mo. To gain some initial insight into these observations, simulations are performed using the drift-kinetic transport code SFINCS for the Mo case. These simulations indicate that, while neoclassical transport prevails for the main plasma components (electrons, majority ions, and low-Z impurities), the classical contribution appears dominant for transporting Mo impurities. In summary, this work reports the first experimental observation of the degradation of mid-Z and high-Z impurity confinement induced by the continuous dropping of Li granules into a high-density stellarator plasma. In the case of the Mo impurity, simulations suggest that classical transport is the key mechanism underlying the enhanced impurity transport.
- 1 May 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (5)
Open AccessEnhancement of mid-/high-Z impurity transport by continuous Li-granule dropping in a stellarator plasma
An enhancement of core impurity transport is observed in high-density plasmas of the stellarator large helical device, heated by neutral beam injection, when continuous lithium (Li) granule dropping is performed. In the reported experiments, in which the tracer-encapsulated solid pellet is employed to inject trace amounts of titanium (Ti) and molybdenum (Mo) into the plasma core, confinement times for these impurities are seen to reduce significantly when Li dropping is applied, this reduction being more notable for Mo. To gain some initial insight into these observations, simulations are performed using the drift-kinetic transport code SFINCS for the Mo case. These simulations indicate that, while neoclassical transport prevails for the main plasma components (electrons, majority ions, and low-Z impurities), the classical contribution appears dominant for transporting Mo impurities. In summary, this work reports the first experimental observation of the degradation of mid-Z and high-Z impurity confinement induced by the continuous dropping of Li granules into a high-density stellarator plasma. In the case of the Mo impurity, simulations suggest that classical transport is the key mechanism underlying the enhanced impurity transport.
- 1 October 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (10) , C10018
Development of an improved dual-path multi-pass Thomson scattering system in GAMMA 10/PDX
We report the development and optimization of a dual-path Thomson scattering (DPTS) system in GAMMA 10/PDX, designed for simultaneous measurements of electron temperature and density in both the central cell and divertor-simulated plasma regions. The system comprises a multi-pass central-cell TS and an upgraded end-cell TS (EC-TS) double-pass configuration, both tailored to enhance signal intensity. Short-pass filters were added to the polychromators to improve spectral selectivity, and newly installed apertures in the EC-TS system were used to suppress stray light. Experimental applications involving supersonic molecular beam injection, central electron cyclotron heating, and ion cyclotron heating confirmed successful concurrent observations of plasma parameters in the central cell.
- 1 October 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (10) , C10018
Development of an improved dual-path multi-pass Thomson scattering system in GAMMA 10/PDX
We report the development and optimization of a dual-path Thomson scattering (DPTS) system in GAMMA 10/PDX, designed for simultaneous measurements of electron temperature and density in both the central cell and divertor-simulated plasma regions. The system comprises a multi-pass central-cell TS and an upgraded end-cell TS (EC-TS) double-pass configuration, both tailored to enhance signal intensity. Short-pass filters were added to the polychromators to improve spectral selectivity, and newly installed apertures in the EC-TS system were used to suppress stray light. Experimental applications involving supersonic molecular beam injection, central electron cyclotron heating, and ion cyclotron heating confirmed successful concurrent observations of plasma parameters in the central cell.
- Open Access
- 1 December 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (12)
Behavior of detached simulation plasma by suddenly changed particle flux in GAMMA 10/PDX
Plasma detachment is one of the most significant factors affecting nuclear fusion reactors. GAMMA 10/PDX has a divertor simulation experimental module (D-module) for detached plasma studies in the end region. To investigate the effect of suddenly changing the higher-density particle flux into the detached plasma condition, similar to edge-localized mode simulations, we performed supersonic molecular beam injection (SMBI) and electron cyclotron heating (ECH) experiments to produce a higher-density and higher-temperature core plasma and introduced it to the divertor simulation plasma in the D-module. With the application of ECH, the detached plasma moved to the attached condition. Moreover, with the injection of SMBI into the ECH-injected plasma, the attached plasma moved to a detached condition. This study revealed the effect of sudden changes in the particle flux on detached simulation plasma for the first time.
- 1 December 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (12)
Open AccessBehavior of detached simulation plasma by suddenly changed particle flux in GAMMA 10/PDX
Plasma detachment is one of the most significant factors affecting nuclear fusion reactors. GAMMA 10/PDX has a divertor simulation experimental module (D-module) for detached plasma studies in the end region. To investigate the effect of suddenly changing the higher-density particle flux into the detached plasma condition, similar to edge-localized mode simulations, we performed supersonic molecular beam injection (SMBI) and electron cyclotron heating (ECH) experiments to produce a higher-density and higher-temperature core plasma and introduced it to the divertor simulation plasma in the D-module. With the application of ECH, the detached plasma moved to the attached condition. Moreover, with the injection of SMBI into the ECH-injected plasma, the attached plasma moved to a detached condition. This study revealed the effect of sudden changes in the particle flux on detached simulation plasma for the first time.
- Open Access
- 23 July 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (9) , 096008
Electron-scale turbulence characteristics with varying electron temperature gradient in LHD
Electron-scale turbulence, whose wavelength is the electron Larmor radius, is thought to have the potential to cause stiffness in an electron temperature gradient and degrade the confinement of future burning plasma in which the electron heating by alpha particles is dominant. The dependence of electron-scale turbulence and electron heat flux on the electron temperature inverse gradient length R ax / L T e , were investigated. The electron temperature gradient was successfully varied in the range of − 3 < R ax / L T e < 12 by controlling the injection power of on/off-axis electron cyclotron heating. The results show a significant increase in the electron-scale turbulence with increasing R ax / L T e , especially in conditions where Electron Temperature Gradient (ETG) instability is linearly unstable, suggesting the presence of ETG turbulence at high R ax / L T e . The electron heat flux also increases steeply with increasing R ax / L T e . In addition, the electron-scale turbulence is observed even at R ax / L T e ∼ 0 , which is stable in linear GKV calculations. Finding the cause of this phenomenon is an interesting task for the future.
- 23 July 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (9) , 096008
Open AccessElectron-scale turbulence characteristics with varying electron temperature gradient in LHD
Electron-scale turbulence, whose wavelength is the electron Larmor radius, is thought to have the potential to cause stiffness in an electron temperature gradient and degrade the confinement of future burning plasma in which the electron heating by alpha particles is dominant. The dependence of electron-scale turbulence and electron heat flux on the electron temperature inverse gradient length R ax / L T e , were investigated. The electron temperature gradient was successfully varied in the range of − 3 < R ax / L T e < 12 by controlling the injection power of on/off-axis electron cyclotron heating. The results show a significant increase in the electron-scale turbulence with increasing R ax / L T e , especially in conditions where Electron Temperature Gradient (ETG) instability is linearly unstable, suggesting the presence of ETG turbulence at high R ax / L T e . The electron heat flux also increases steeply with increasing R ax / L T e . In addition, the electron-scale turbulence is observed even at R ax / L T e ∼ 0 , which is stable in linear GKV calculations. Finding the cause of this phenomenon is an interesting task for the future.
- Open Access
- 17 January 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-11
First application of data assimilation-based control to fusion plasma
Magnetic fusion plasmas, which are complex systems comprising numerous interacting elements, have large uncertainties. Therefore, future fusion reactors require prediction-based advanced control systems with an adaptive system model and control estimation robust to uncertainties in the model and observations. To address this challenge, we introduced a control approach based on data assimilation (DA), which describes the system model adaptation and control estimation based on the state probability distribution. The first implementation of a DA-based control system was achieved at the Large Helical Device to control the high temperature plasma. The experimental results indicate that the control system enhanced the predictive capability using real-time observations and adjusted the electron cyclotron heating power for a target temperature. The DA-based control system provides a flexible platform for advanced control in future fusion reactors.
- 17 January 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-11
Open AccessFirst application of data assimilation-based control to fusion plasma
Magnetic fusion plasmas, which are complex systems comprising numerous interacting elements, have large uncertainties. Therefore, future fusion reactors require prediction-based advanced control systems with an adaptive system model and control estimation robust to uncertainties in the model and observations. To address this challenge, we introduced a control approach based on data assimilation (DA), which describes the system model adaptation and control estimation based on the state probability distribution. The first implementation of a DA-based control system was achieved at the Large Helical Device to control the high temperature plasma. The experimental results indicate that the control system enhanced the predictive capability using real-time observations and adjusted the electron cyclotron heating power for a target temperature. The DA-based control system provides a flexible platform for advanced control in future fusion reactors.
- Open Access
- 1 March 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (3) , 032504
Direct observation of the non-locality of non-diffusive counter-gradient electron thermal transport during the formation of hollow electron-temperature profiles in the Large Helical Device
A heating source with off-axis electron cyclotron heating (ECH) alone produced a plasma with a quasi-steady-state hollow electron-temperature profile in the Large Helical Device. The clear formation of this quasi-steady-state hollow electron-temperature profile can be explained by adding the outward heat convection term to the diffusion term, as a simple model to describe the electron heat flux, using the energy conservation equation. In addition, we directly observed the non-locality of the non-diffusive (convective) contribution in transient electron thermal transport in the condition that power-modulated on-axis ECH was applied to the plasma sustained by off-axis ECH. The experimentally evaluated flux-gradient relation shows two different positive values of the electron heat flux at zero temperature gradient by going back and forth between positive and negative temperature gradient regions in the transport hysteresis phenomenon.
- 1 March 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (3) , 032504
Open AccessDirect observation of the non-locality of non-diffusive counter-gradient electron thermal transport during the formation of hollow electron-temperature profiles in the Large Helical Device
A heating source with off-axis electron cyclotron heating (ECH) alone produced a plasma with a quasi-steady-state hollow electron-temperature profile in the Large Helical Device. The clear formation of this quasi-steady-state hollow electron-temperature profile can be explained by adding the outward heat convection term to the diffusion term, as a simple model to describe the electron heat flux, using the energy conservation equation. In addition, we directly observed the non-locality of the non-diffusive (convective) contribution in transient electron thermal transport in the condition that power-modulated on-axis ECH was applied to the plasma sustained by off-axis ECH. The experimentally evaluated flux-gradient relation shows two different positive values of the electron heat flux at zero temperature gradient by going back and forth between positive and negative temperature gradient regions in the transport hysteresis phenomenon.
- 1 February 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (2) , 029902
Publisher’s Note: “Study of detached plasma profile in the divertor simulation experimental module of tandem mirror GAMMA 10/PDX” [AIP Advances 11, 125231 (2021)]
- 1 February 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (2) , 029902
Publisher’s Note: “Study of detached plasma profile in the divertor simulation experimental module of tandem mirror GAMMA 10/PDX” [AIP Advances 11, 125231 (2021)]
- Open Access
- 1 December 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (12) , 125231
Study of detached plasma profile in the divertor simulation experimental module of tandem mirror GAMMA 10/PDX
A divertor simulation experimental module (D-module) in the tandem mirror GAMMA 10/PDX was used for the study of plasma detachment. In previous studies, it was difficult to measure far-upstream plasma parameters in the D-module, and only electrostatic probes on the target plate were used to perform electron temperature and density measurements. To study the detached plasma structure, a Thomson scattering (TS) system and a microwave interferometer system have been installed to measure the inside plasma parameters of the D-module, and a movable electrostatic probe has been placed at the inlet of the D-module to measure the inlet plasma density and temperature. The TS system in the central cell observed the electron temperature and density of the core plasma simultaneously. These measurements revealed the entire density and temperature structure from the core plasma to the divertor plate. The line average electron density measured by the microwave interferometer showed a rollover behavior during detachment. The results indicated that the ionization region was located around the center of the D-module, and it appears to move upstream along the axis.
- 1 December 2021
- Published by AIP Publishing in AIP Advances
- Vol. 11 (12) , 125231
Open AccessStudy of detached plasma profile in the divertor simulation experimental module of tandem mirror GAMMA 10/PDX
A divertor simulation experimental module (D-module) in the tandem mirror GAMMA 10/PDX was used for the study of plasma detachment. In previous studies, it was difficult to measure far-upstream plasma parameters in the D-module, and only electrostatic probes on the target plate were used to perform electron temperature and density measurements. To study the detached plasma structure, a Thomson scattering (TS) system and a microwave interferometer system have been installed to measure the inside plasma parameters of the D-module, and a movable electrostatic probe has been placed at the inlet of the D-module to measure the inlet plasma density and temperature. The TS system in the central cell observed the electron temperature and density of the core plasma simultaneously. These measurements revealed the entire density and temperature structure from the core plasma to the divertor plate. The line average electron density measured by the microwave interferometer showed a rollover behavior during detachment. The results indicated that the ionization region was located around the center of the D-module, and it appears to move upstream along the axis.
- 1 June 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (6) , 063523
Initial operation and data processing on a system for real-time evaluation of Thomson scattering signals on the Large Helical Device
A scalable system for real-time analysis of electron temperature and density based on signals from the Thomson scattering diagnostic, initially developed for and installed on the NSTX-U experiment, was recently adapted for the Large Helical Device and operated for the first time during plasma discharges. During its initial operation run, it routinely recorded and processed signals for four spatial points at the laser repetition rate of 30 Hz, well within the system’s rated capability for 60 Hz. We present examples of data collected from this initial run and describe subsequent adaptations to the analysis code to improve the fidelity of the temperature calculations.
- 1 June 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (6) , 063523
Initial operation and data processing on a system for real-time evaluation of Thomson scattering signals on the Large Helical Device
A scalable system for real-time analysis of electron temperature and density based on signals from the Thomson scattering diagnostic, initially developed for and installed on the NSTX-U experiment, was recently adapted for the Large Helical Device and operated for the first time during plasma discharges. During its initial operation run, it routinely recorded and processed signals for four spatial points at the laser repetition rate of 30 Hz, well within the system’s rated capability for 60 Hz. We present examples of data collected from this initial run and describe subsequent adaptations to the analysis code to improve the fidelity of the temperature calculations.
- 1 March 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (3) , 033515
Improvement in multipass Thomson scattering system comprising laser amplification system developed in GAMMA 10/PDX
The multipass Thomson scattering (MPTS) technique is one of the most useful methods for measuring low-electron-density plasmas. The MPTS system increases Thomson scattering (TS) signal intensities by integrating all multipass (MP) signals and improving the TS time resolution by analyzing each pass signal. The fully coaxial MPTS system developed in GAMMA 10/potential-control and diverter–simulator experiments has a polarization-based configuration with image-relaying optics. The MPTS system can enhance Thomson scattered signals for improving the measurement accuracy and megahertz-order time resolution. In this study, we develop a new MPTS system comprising a laser amplification system to obtain continuous MP signals. The laser amplification system can improve degraded laser power and return an amplified laser to the MP system. We obtain continuous MP signals from the laser amplification system by improving the laser beam profile adjuster in gas scattering experiments. Moreover, we demonstrate that more MP signals and stronger amplified MP signals can be achieved via multiple laser injections to the laser amplification system in the developed MP system comprising a laser amplification system.
- 1 March 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (3) , 033515
Improvement in multipass Thomson scattering system comprising laser amplification system developed in GAMMA 10/PDX
The multipass Thomson scattering (MPTS) technique is one of the most useful methods for measuring low-electron-density plasmas. The MPTS system increases Thomson scattering (TS) signal intensities by integrating all multipass (MP) signals and improving the TS time resolution by analyzing each pass signal. The fully coaxial MPTS system developed in GAMMA 10/potential-control and diverter–simulator experiments has a polarization-based configuration with image-relaying optics. The MPTS system can enhance Thomson scattered signals for improving the measurement accuracy and megahertz-order time resolution. In this study, we develop a new MPTS system comprising a laser amplification system to obtain continuous MP signals. The laser amplification system can improve degraded laser power and return an amplified laser to the MP system. We obtain continuous MP signals from the laser amplification system by improving the laser beam profile adjuster in gas scattering experiments. Moreover, we demonstrate that more MP signals and stronger amplified MP signals can be achieved via multiple laser injections to the laser amplification system in the developed MP system comprising a laser amplification system.