Dilek Toktamis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dilek Toktamis has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Hüseyin Toktamış
Department of Engineering Physics University of Gaziantep Gaziantep Turkey
4 shared publications - Esme Isik
Department of Electronics and Automation Malatya Turgut Ozal University Malatya Türkiye
2 shared publications - Mehmet Bilal Er
Department of Software Engineering, Harran University, 63050 Şanlıurfa, Türkiye
2 shared publications - A. Necmeddin Yazici
Gaziantep University Gaziantep Turkey
1 shared publication Ahmet Necmeddin Yazıcı
Department of Engineering Physics Gaziantep University Gaziantep Turkey
1 shared publicationAyşen Yılmaz
Department of Chemistry Middle East Technical University Ankara Turkey
1 shared publication
Latest Publications
- 27 October 2025
- Published by Wiley in Luminescence
- Vol. 40 (10) , e70341
Effect of Ag Doping on Thermoluminescence Properties and Radiation Dosimetry Performance of MgB₄O₇
This study investigates the thermoluminescence (TL) properties of silver (Ag)‐doped magnesium tetraborate (MgB₄O₇, MBO) for radiation dosimetry applications. MBO, known for its tissue‐equivalent properties, was synthesized via the solid‐state reaction method with Ag doping concentrations of 0.1 wt%, 0.5 wt% and 1.0 wt%. Comprehensive TL experiments were conducted to evaluate key dosimetric properties such as dose response, reusability, fading and heating rate. Additionally, kinetic parameters were derived using the glow curve decomposition (CGCD) and variable heating rate (VHR) methods. The TL glow curves demonstrated that Ag doping significantly enhances the TL signal intensity, particularly at higher doping levels, indicating an impact on trap density and energy release mechanisms. The 1.0 wt% Ag‐doped MBO sample exhibited high TL signal intensity and optimal trap stability, making it suitable for applications requiring high sensitivity. Dose–response experiments confirmed the linearity of the TL signal up to high radiation doses (4.6 kGy), while cycling tests validated the material's good reusability and thermal stability. Overall, these findings demonstrate that Ag doping, especially at 1.0 wt%, is an effective approach to enhance the dosimetric performance of MBO, strengthening its potential as a robust candidate for advanced radiation dosimetry systems.
- 27 October 2025
- Published by Wiley in Luminescence
- Vol. 40 (10) , e70341
Effect of Ag Doping on Thermoluminescence Properties and Radiation Dosimetry Performance of MgB₄O₇
This study investigates the thermoluminescence (TL) properties of silver (Ag)‐doped magnesium tetraborate (MgB₄O₇, MBO) for radiation dosimetry applications. MBO, known for its tissue‐equivalent properties, was synthesized via the solid‐state reaction method with Ag doping concentrations of 0.1 wt%, 0.5 wt% and 1.0 wt%. Comprehensive TL experiments were conducted to evaluate key dosimetric properties such as dose response, reusability, fading and heating rate. Additionally, kinetic parameters were derived using the glow curve decomposition (CGCD) and variable heating rate (VHR) methods. The TL glow curves demonstrated that Ag doping significantly enhances the TL signal intensity, particularly at higher doping levels, indicating an impact on trap density and energy release mechanisms. The 1.0 wt% Ag‐doped MBO sample exhibited high TL signal intensity and optimal trap stability, making it suitable for applications requiring high sensitivity. Dose–response experiments confirmed the linearity of the TL signal up to high radiation doses (4.6 kGy), while cycling tests validated the material's good reusability and thermal stability. Overall, these findings demonstrate that Ag doping, especially at 1.0 wt%, is an effective approach to enhance the dosimetric performance of MBO, strengthening its potential as a robust candidate for advanced radiation dosimetry systems.
- Open Access
- 4 June 2025
- Published by Wiley in Luminescence
- Vol. 40 (6) , e70217
Investigation of the Use of Naturally Grown CaCO 3 Crystals on Rocks as a Radiation Dosimeter via Thermoluminescence Method
This study investigates the thermoluminescence (TL) characteristics of naturally occurring CaCO 3 crystals found on rocks collected from the Akçatekir region of Adana, Turkey. The research evaluates some of the radiation dosimeter parameters such as dose–response, heating rate, reusability, and fading. Both crystals demonstrate favorable TL properties with distinct TL glow curves. One of the crystals exhibits two prominent TL peaks at approximately 90°C and 235°C, while the other shows peaks around 115°C and 300°C. Both crystals display a broad linear dose–response range from 2 to 576 Gy. Although repeated experiments lead to a reduction in the low‐temperature peak, the dosimetric peak (near 220°C) remains largely unaffected. Additionally, TL intensity decreases as the waiting time between irradiation and measurement increases. However, the fading process does not compromise the structural integrity of the crystals or introduce new TL peaks. Given their wide linear dose–response range, strong reusability with standard deviation of 2.71%, and stable dosimetric peak under ambient conditions, these crystals appear to be promising candidates for dosimetric applications.
- 4 June 2025
- Published by Wiley in Luminescence
- Vol. 40 (6) , e70217
Open AccessInvestigation of the Use of Naturally Grown CaCO 3 Crystals on Rocks as a Radiation Dosimeter via Thermoluminescence Method
This study investigates the thermoluminescence (TL) characteristics of naturally occurring CaCO 3 crystals found on rocks collected from the Akçatekir region of Adana, Turkey. The research evaluates some of the radiation dosimeter parameters such as dose–response, heating rate, reusability, and fading. Both crystals demonstrate favorable TL properties with distinct TL glow curves. One of the crystals exhibits two prominent TL peaks at approximately 90°C and 235°C, while the other shows peaks around 115°C and 300°C. Both crystals display a broad linear dose–response range from 2 to 576 Gy. Although repeated experiments lead to a reduction in the low‐temperature peak, the dosimetric peak (near 220°C) remains largely unaffected. Additionally, TL intensity decreases as the waiting time between irradiation and measurement increases. However, the fading process does not compromise the structural integrity of the crystals or introduce new TL peaks. Given their wide linear dose–response range, strong reusability with standard deviation of 2.71%, and stable dosimetric peak under ambient conditions, these crystals appear to be promising candidates for dosimetric applications.
- 7 May 2024
- Published by Wiley in Luminescence
- Vol. 39 (5) , e4767
Investigation of zinc polycarboxylate cement used in dental treatments in terms of retrospective dosimeter
Zinc polycarboxylate cement is one of the few dental materials that demonstrate true adhesion to tooth structure. It is suitable for use in living organisms without causing harm. Its strong adhesion to teeth and low level of irritancy are two important parameters for the dental applications. In this study, the dosimetry properties of zinc polycarboxylate cement using thermoluminescence (TL) method were investigated and determined the effectiveness of its use as a good dosimeter. According to the results of this study, the sample shows a good TL properties with three main peaks found around 140°C, 220°C and 330°C. It has a wide linear dose response between 72 Gy and 2.3 kGy and good reusability of the TL peak found at 330°C. Unfortunately, the TL peak intensity values are rapidly faded within a short waiting time interval. Zinc polycarboxylate cement, which is frequently used in dental crowns, can be used as a retrospective dosimeter for measuring the amount of radiation in space studies and nuclear accidents due to its wide linear dose–response curve in the high dose region.
- 7 May 2024
- Published by Wiley in Luminescence
- Vol. 39 (5) , e4767
Investigation of zinc polycarboxylate cement used in dental treatments in terms of retrospective dosimeter
Zinc polycarboxylate cement is one of the few dental materials that demonstrate true adhesion to tooth structure. It is suitable for use in living organisms without causing harm. Its strong adhesion to teeth and low level of irritancy are two important parameters for the dental applications. In this study, the dosimetry properties of zinc polycarboxylate cement using thermoluminescence (TL) method were investigated and determined the effectiveness of its use as a good dosimeter. According to the results of this study, the sample shows a good TL properties with three main peaks found around 140°C, 220°C and 330°C. It has a wide linear dose response between 72 Gy and 2.3 kGy and good reusability of the TL peak found at 330°C. Unfortunately, the TL peak intensity values are rapidly faded within a short waiting time interval. Zinc polycarboxylate cement, which is frequently used in dental crowns, can be used as a retrospective dosimeter for measuring the amount of radiation in space studies and nuclear accidents due to its wide linear dose–response curve in the high dose region.
- 4 April 2023
- Published by Wiley in Luminescence
- Vol. 38 (5) , 637-646
Thermoluminescence properties of the rock naturally annealed for thousands of years by flames from the earth's inner layers
The gas leak in Chimaera near Çıralı, Antalya, has been active for thousands of years. It is also known to be the source of the first Olympic flame in the Hellenistic period. The sample taken from the Chimaere seepage annealed for thousands of years was determined to be calcite‐magnesian (Ca, Mg)O3. In this study, thermoluminescence (TL) properties of calcite‐magnesian annealed for thousands of years in the fire caused by methane gas were investigated for particle size, dose–response, heating rate, and fading experiments. It exhibits a clear TL glow curve with two distinct peaks positioned at 160 and 330°C, and its shape is not affected by variation in applied dose and reproduciility of experiment. There is a wide linear relationship between TL output and applied dose up to 614 Gy. Although the positions of the TL peaks are stable with the cycle of measurement, a poor reusability was observed in terms of the area under the TL glow curve and peak intensity.
- 4 April 2023
- Published by Wiley in Luminescence
- Vol. 38 (5) , 637-646
Thermoluminescence properties of the rock naturally annealed for thousands of years by flames from the earth's inner layers
The gas leak in Chimaera near Çıralı, Antalya, has been active for thousands of years. It is also known to be the source of the first Olympic flame in the Hellenistic period. The sample taken from the Chimaere seepage annealed for thousands of years was determined to be calcite‐magnesian (Ca, Mg)O3. In this study, thermoluminescence (TL) properties of calcite‐magnesian annealed for thousands of years in the fire caused by methane gas were investigated for particle size, dose–response, heating rate, and fading experiments. It exhibits a clear TL glow curve with two distinct peaks positioned at 160 and 330°C, and its shape is not affected by variation in applied dose and reproduciility of experiment. There is a wide linear relationship between TL output and applied dose up to 614 Gy. Although the positions of the TL peaks are stable with the cycle of measurement, a poor reusability was observed in terms of the area under the TL glow curve and peak intensity.
- 15 February 2023
- Published by Wiley in Luminescence
- Vol. 38 (3) , 318-325
Thermoluminescence in pumice stone collected from the Mediterranean coast
Pumice is a low‐density, light‐coloured volcanic rock (igneous rock) formed when the magma from a volcanic eruption is suddenly cooled. It has a porous structure and can be different colours and have different densities. Pumice stone, unlike other rock, does not sink in water because it has a low density. In the present study, the thermoluminescent (TL) dosimetric characteristics, such as the dose–response, TL signal fading as a function of storage time, heating rate, and reusability of pumice collected on the Mediterranean coast were investigated. From this study, it was concluded that the pumice stone showed TL properties with a TL glow curve including an obviously wide peak at ∼200°C. A wide linear dose–response region up to 144 Gy, low fading of the TL signal when it was kept in a dark room for a long time, and poor reusability properties were observed for dosimetry use.
- 15 February 2023
- Published by Wiley in Luminescence
- Vol. 38 (3) , 318-325
Thermoluminescence in pumice stone collected from the Mediterranean coast
Pumice is a low‐density, light‐coloured volcanic rock (igneous rock) formed when the magma from a volcanic eruption is suddenly cooled. It has a porous structure and can be different colours and have different densities. Pumice stone, unlike other rock, does not sink in water because it has a low density. In the present study, the thermoluminescent (TL) dosimetric characteristics, such as the dose–response, TL signal fading as a function of storage time, heating rate, and reusability of pumice collected on the Mediterranean coast were investigated. From this study, it was concluded that the pumice stone showed TL properties with a TL glow curve including an obviously wide peak at ∼200°C. A wide linear dose–response region up to 144 Gy, low fading of the TL signal when it was kept in a dark room for a long time, and poor reusability properties were observed for dosimetry use.
- Open Access
- 30 September 2022
- Published by Cumhuriyet University in Cumhuriyet Science Journal
- Vol. 43 (3) , 515-519
The Effect of Experimental Cycles on the Traps Depths of Dosimetric Traps of Natural Calcite Minerals
A trap found in a solid state radiation dosimetry is characterized by kinetic parameters such as trap depth (Ea), frequency factor (s), kinetic order (b) and carrier concentration (no). Trap depth (Activation energy) is the required energy to release carriers in the trap. In this study, it is investigated that how the dosimetric trap depths of the traps found in the four natural calcite minerals are affected by reusable of them as a dosimeter. All samples were irradiated about 36 Gy beta dose and read out by a thermoluminescence dosimeter (TLD) reader. A computer glow curve deconvulation program (CGCD) was used to get the kinetic parameters. And the results are compared for the four calcite samples.
- 30 September 2022
- Published by Cumhuriyet University in Cumhuriyet Science Journal
- Vol. 43 (3) , 515-519
Open AccessThe Effect of Experimental Cycles on the Traps Depths of Dosimetric Traps of Natural Calcite Minerals
A trap found in a solid state radiation dosimetry is characterized by kinetic parameters such as trap depth (Ea), frequency factor (s), kinetic order (b) and carrier concentration (no). Trap depth (Activation energy) is the required energy to release carriers in the trap. In this study, it is investigated that how the dosimetric trap depths of the traps found in the four natural calcite minerals are affected by reusable of them as a dosimeter. All samples were irradiated about 36 Gy beta dose and read out by a thermoluminescence dosimeter (TLD) reader. A computer glow curve deconvulation program (CGCD) was used to get the kinetic parameters. And the results are compared for the four calcite samples.
- 21 February 2022
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 177 (3-4) , 360-371
Classification of thermoluminescence features of the natural halite with machine learning
Radiation dosimeters are used to measure the absorbed radiation dose of any living organism during the time intervals. They include defective crystals that store radiation until they are stimulated. Thermoluminescence (TL) is a way to see the absorbed dose of the dosimeters. The irradiated crystal is heated up to 500°C to reveal the absorbed dose as a luminescence light. The TL dosimetric properties of natural halite (rock-salt) crystals extracted from Meke crater lake in Konya, Turkey, were investigated in this study. Support Vector Machine (SVM), Artificial Neural Network (ANN) and K-Nearest Neighbor (K-NN) were also examined utilizing machine learning for categorization of TL characteristics. According to the experimental output, the TL glow curve has two main peaks located at 100 and 270°C with good dosimetric properties. In the three classifiers, SVM has the biggest accuracy and precision. High training-low testing and results from normalized data give the best accuracy, precision, sensitivity and F-score.
- 21 February 2022
- Published by Taylor & Francis in Radiation Effects and Defects in Solids
- Vol. 177 (3-4) , 360-371
Classification of thermoluminescence features of the natural halite with machine learning
Radiation dosimeters are used to measure the absorbed radiation dose of any living organism during the time intervals. They include defective crystals that store radiation until they are stimulated. Thermoluminescence (TL) is a way to see the absorbed dose of the dosimeters. The irradiated crystal is heated up to 500°C to reveal the absorbed dose as a luminescence light. The TL dosimetric properties of natural halite (rock-salt) crystals extracted from Meke crater lake in Konya, Turkey, were investigated in this study. Support Vector Machine (SVM), Artificial Neural Network (ANN) and K-Nearest Neighbor (K-NN) were also examined utilizing machine learning for categorization of TL characteristics. According to the experimental output, the TL glow curve has two main peaks located at 100 and 270°C with good dosimetric properties. In the three classifiers, SVM has the biggest accuracy and precision. High training-low testing and results from normalized data give the best accuracy, precision, sensitivity and F-score.
- 22 June 2021
- Published by Wiley in Luminescence
- Vol. 36 (7) , 1684-1689
Classification of thermoluminescence features of CaCO3 with long short‐term memory model
Calcium carbonate (CaCO3), a mineral commonly found in the Earth's crust, is mainly in the forms of calcite and aragonite. Calcite has the most stable type of thermodynamics at room temperature and ambient pressure. It has wide band gap structure and is of great interest for a wide‐range technical and industrial applications due to its physical properties and suitability. In this study, a new method based on the long short‐term memory (LSTM) model of deep learning is proposed to classify the thermoluminescence properties such as fading, cycle of measurement, heating rate, and dose–response of CaCO3. Therefore the thermoluminescence properties of calcite was investigated as a suitable band structure and its coherent data were used to classify the features using a deep learning LSTM model. Experiments were carried out on a dataset consisting of four classes. The accuracy, precision, and sensitivity values of the proposed model obtained were 98.34, 97.90, and 98.56%, respectively. The classification process of the results obtained from the designed model showed good performance.
- 22 June 2021
- Published by Wiley in Luminescence
- Vol. 36 (7) , 1684-1689
Classification of thermoluminescence features of CaCO3 with long short‐term memory model
Calcium carbonate (CaCO3), a mineral commonly found in the Earth's crust, is mainly in the forms of calcite and aragonite. Calcite has the most stable type of thermodynamics at room temperature and ambient pressure. It has wide band gap structure and is of great interest for a wide‐range technical and industrial applications due to its physical properties and suitability. In this study, a new method based on the long short‐term memory (LSTM) model of deep learning is proposed to classify the thermoluminescence properties such as fading, cycle of measurement, heating rate, and dose–response of CaCO3. Therefore the thermoluminescence properties of calcite was investigated as a suitable band structure and its coherent data were used to classify the features using a deep learning LSTM model. Experiments were carried out on a dataset consisting of four classes. The accuracy, precision, and sensitivity values of the proposed model obtained were 98.34, 97.90, and 98.56%, respectively. The classification process of the results obtained from the designed model showed good performance.
- 28 July 2020
- Published by Wiley in Luminescence
- Vol. 36 (1) , 142-148
Thermoluminescence properties of unique Rosso Levanto marble
This marble extracted from deposits in Elazığ in Turkey resembles red meat in appearance and is only found in Elazığ. This type of marble has been widely used in the most famous architectural structures and buildings. In this study, the thermoluminescence (TL) properties of a unique marble that originated from Turkey, named Rosso Levanto, were investigated. Two distinct TL peaks were observed at 160°C and around 375°C. Particle size experiments showed that best TL intensity was seen at 200 μm particle size and therefore dose–response, heating rate, cycle of measurement and fading experiments were carried out on powdered samples with a particle size of 200 μm. The findings revealed good linearity in dose–response, observed up to 0.5 kGy. The reproducibility experiment gave good results, but peak intensity decreased by about 40% in first 6 h of storage in a dark room.
- 28 July 2020
- Published by Wiley in Luminescence
- Vol. 36 (1) , 142-148
Thermoluminescence properties of unique Rosso Levanto marble
This marble extracted from deposits in Elazığ in Turkey resembles red meat in appearance and is only found in Elazığ. This type of marble has been widely used in the most famous architectural structures and buildings. In this study, the thermoluminescence (TL) properties of a unique marble that originated from Turkey, named Rosso Levanto, were investigated. Two distinct TL peaks were observed at 160°C and around 375°C. Particle size experiments showed that best TL intensity was seen at 200 μm particle size and therefore dose–response, heating rate, cycle of measurement and fading experiments were carried out on powdered samples with a particle size of 200 μm. The findings revealed good linearity in dose–response, observed up to 0.5 kGy. The reproducibility experiment gave good results, but peak intensity decreased by about 40% in first 6 h of storage in a dark room.